5.9.2.1 An analytical system for the determination
of the gaseous emissions (CO, CO2, HC, NOx,
O2) in the raw exhaust gas shall be based on the use of
the following analysers:
-
.1 HFID analyser for the measurement of hydrocarbons;
-
.2 NDIR analyser for the measurement of carbon
monoxide and carbon dioxide;
-
.3 HCLD or equivalent analyser for the measurement
of nitrogen oxides; and
-
.4 PMD, ECS or ZRDO for the measurement of oxygen.
5.9.2.2 For the raw exhaust gas, the sample for
all components may be taken with one sampling probe or with two sampling
probes located in close proximity and internally split to the different
analysers. Care must be taken that no condensation of the exhaust
components (including water and sulphuric acid) occurs at any point
of the analytic system.
5.9.2.3 Specifications and calibration of these
analysers shall be as set out in appendices 3 and 4 of this Code, respectively.