Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC/Circular.669 – Interpretations of SOLAS Chapter II-2, As Amended by Resolution MSC.27(61) – (Adopted on 22 December 1994) - Annex - Interpretations of SOLAS Chapter II-2, As Amended by Resolution MSC.27(61) - 2 Regulation II-2/24 - Main vertical zones and horizontal zones

2 Regulation II-2/24 - Main vertical zones and horizontal zones

 If a stairway serves two main vertical zones, the maximum length of one main vertical zone should be measured from the far side of the main vertical zone stairway enclosure. In this case, all boundaries of the stairway enclosure should be insulated as main vertical zone bulkheads and access doors leading into the stairway should be provided from the zones (see figures 1 to 4 in the appendix). However, if the stairway should not be included in calculating the size of the main vertical zone if it is treated as its own main vertical zone.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.