                           35.1.1 
                           
                              Construction and location of
                                 draught stops:
                              
                           
                        
                           
                           
                              
                              
                                 
                                    
                                    
                                    
                                       1 Any of the following methods of construction
                                       may be used to construct draught stops
                                     
                                       
                                          
                                          
                                          
                                             .1 the extension of the "B" class bulkhead, ceiling
                                             or lining;
                                          
                                          
                                          
                                          
                                             .2 the extension of the "C" class bulkhead, ceiling
                                             or lining;
                                          
                                          
                                          
                                          
                                             .3 1 mm thick minimum steel sheet, stiffened where
                                             necessary, intermittently welded to the ship's structure and the top
                                             profile of the bulkhead, or fastened mechanically to the ceilings
                                             or linings;
                                          
                                          
                                          
                                          
                                             .4 non-combustible board type material fastened
                                             mechanically to the ship's structure, bulkheads, ceilings or linings;
                                             or
                                          
                                          
                                          
                                          
                                             .5 "A" class mineral wool insulation, not less
                                             than 20 mm in thickness, faced on each side with expanded metal mesh,
                                             the mesh on one side being attached to the ship's structure, or expanded
                                             metal mesh may be fitted on one side and non-combustible cloth (glass-cloth)
                                             on the other side of mineral wool insulation.
                                           Other
                                       equivalent arrangements may be accepted.
                                    
                                    
                                    
                                    
                                       2 In general, the draught stops should coincide
                                       with the bulkheads where continuous ceilings are used.
                                    
                                    
                                    
                                    
                                       3 Draught stops are not required in public spaces
                                       with open ceilings (perforated ceilings) with openings of 40% or more
                                       and arranged in such a way that a fire behind the ceiling can be seen
                                       and extinguished.
                                     | 
         
            | 
 | 
         
            | 
                  
                  
                  
                  
                     
                        | Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime
                           and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective
                           officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications
                           Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance
                           on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
                           Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is
                           exclusively on the terms and conditions set out in that contract. |  |  |