5.4.1 Exhaust gas composition in terms of SO2 (ppm)/CO2 (%) should be measured at an appropriate position after the
EGC unit and that measurement should be in accordance with the requirements
of section 6 as applicable.
5.4.2 SO2 (ppm) and CO2 (%)
to be continuously monitored and recorded onto a data recording and
processing device at a rate which should not be less than 0.0035 Hz.
5.4.3 If more than one analyser is to be used
to determine the SO2/CO2 ratio, these should
be tuned to have similar sampling and measurement times and the data
outputs aligned so that the SO2/CO2 ratio is
fully representative of the exhaust gas composition.