8.1 An OMM should be prepared to cover each EGC
unit installed in conjunction with fuel oil combustion equipment,
which should be identified, for which compliance is to be demonstrated.
8.2 The OMM should, as a minimum, include:
-
(a) the sensors to be used in evaluating EGC system
performance and washwater monitoring, their service, maintenance and
calibration requirements;
-
(b) the positions from which exhaust emission
measurements and washwater monitoring are to be taken together with
details of any necessary ancillary services such as sample transfer
lines and sample treatment units and any related service or maintenance
requirements;
-
(c) the analysers to be used, their service, maintenance,
and calibration requirements;
-
(d) analyser zero and span check procedures; and
-
(e) other information or data relevant to the
correct functioning of the monitoring systems or its use in demonstrating
compliance.
8.3 The OMM should specify how the monitoring
is to be surveyed.
8.4 The OMM should be approved by the Administration.