2.1 The intent of this part is to present a methodology
for performing simplified fire risk assessments of external areas.
These Guidelines should not be used to evaluate changes to permanent
structure such as bulkheads, decks or surface finishes, or to demonstrate
compliance with SOLAS regulation II-2/17.
2.2 The simplified fire risk assessment consists
of the following elements:
-
.1 description of the intended use of the area;
-
.2 identification of the combustible materials;
-
.3 identification of the ignition sources;
-
.4 description of the means of escape from, and
fire-fighting access to the area;
-
.5 description of the materials used for the construction
of the decks and bulkheads that bound the area (if any);
-
.6 description of the fire-fighting systems and
appliances in the area (if any);
-
.7 description of the fire detection and alarm
systems in the area (if any);
-
.8 response procedures;
-
.9 identification of essential systems;
-
.10 identification of any ventilation intakes
or equipment in or near the area;
-
.11 effects on other areas; and
-
.12 evaluation of the risk assessment.