4.1 General 
                     
                     
                     
                     
                     4.1.1
                        
                     
                     
                     
                     
                     The NDE plan to be submitted for approval has to contain the necessary data
                        relevant to the locations and number of examinations, welding procedures applied, method
                        of NDE applied, etc. Visual inspection of finished welds is to be carried out by the
                        shipyard to ensure that all welding has been satisfactory completed. In addition to
                        visual inspection, welded joints are to be examined using any one or a combination of
                        ultrasonic, radiographic, magnetic particle, eddy current, dye penetrant or other
                        acceptable methods appropriate to the configuration of the weld. Above inspections are
                        to be carried out as per the requirements of the Society. 
                     
                     
                     
                     
                     4.1.2
                        
                     
                     
                     
                     
                     NDE of welding is to be carried out at the positions indicated by the NDE
                        plan in order to ensure that the welds are free from cracks and unacceptable internal
                        defects with regards to the requirements of the Society. NDE is to be carried out by
                        qualified personnel certified by recognised bodies in compliance with recognised
                        standards.