10.1.1 Drop weight specimens for the determination of no–break performance are to comply
with ASTM E208 and have one of the following dimensions (mm):
Type P-1: 25×90×360
Type P-2: 19×50×130
Type P-3 : 16×50×130
10.1.2 If not otherwise specified:
- the specimen sides shall be saw-cut or machined (minimum 25 mm to flame-cut
surface)
- the machining of the plate to prescribed specimen thickness shall be on one
side only
- the specimens may be of any orientation, but the orientation shall be the
same for all specimens.