1.2 “Fire-restricting materials" are defined
in 7.2.2 of the code.
1.3 Surface materials on bulkheads, wall and ceiling
linings, including their supporting structure should be tested to
the standard ISO 9705 as described in section
2. Bulkhead, wall and ceiling linings should be tested in their
end-use configuration, including any surface finish materials.
1.4 Materials used for furniture and other components
should be tested to the standard ISO 5660 as described in section 2. (This does not include vertically
supported textiles and films, upholstery, or bedding which should
be tested in accordance with the Fire Test Procedures Code.)
1.5 In the case of combustible insulation materials
that are protected by metallic skins or identifiable as a separate
item, the insulation should be tested without the surface protection.