1 IACS UR E10 may be used as an equivalent test
standard to IEC 60092-504.
2 The range of tests should include the following:
-
For alarm/monitoring panel:
-
.1 functional tests in accordance with resolution
MSC.188(79) – Performance standards for water level detectors on bulk
carriers and single hold cargo ships other than bulk carriers;
-
.2 electrical power supply failure test;
-
.3 power supply variation test;
-
.4 dry heat tests;
-
.5 damp heat tests;
-
.6 vibration test;
-
.7 EMC tests;
-
.8 insulation resistance test;
-
.9 high-voltage test; and
-
.10 static and dynamic inclinations tests, if
moving parts are contained.
-
For IS barrier unit, if located in the wheelhouse: in addition
to the certificate issued by a competent independent testing laboratory,
EMC tests should also be carried out.
-
For water ingress detectors:
-
.1 functional tests in accordance with resolution
MSC.188(79) – Performance standards for water level detectors on bulk
carriers and single hold cargo ships other than bulk carriers;
-
.2 electrical power supply failure test;
-
.3 power supply variation test;
-
.4 dry-heat test;
-
.5 damp-heat test;
-
.6 vibration test;
-
.7 enclosure class in accordance with resolution
MSC.188(79) – Performance standards for water level detectors on bulk
carriers and single hold cargo ships other than bulk carriers;
-
.8 insulation resistance test;
-
.9 high-voltage test; and
-
.10 static and dynamic inclinations tests (if
the detectors contain moving parts).