8.1.2 When units are fitted with riser systems the arrangements are to be
designed to minimise the effect of ice loadings on the risers.
8.1.3 Suitable steam generating equipment or an equivalent means is to be
provided, with outlets and hoses, to keep designated areas free of ice and snow such
that operation and inspection/maintenance may be conducted safely. Such equipment is
to be capable of being used in at least the following locations:
- The working areas.
- The helicopter deck.
- Walkways and escape routes.
- Lifeboat embarkation station.
8.1.4 In the case of self-elevating units where the design of the elevating
machinery is required to operate in ice conditions, suitable de-icing equipment is
to be provided.
8.1.6 Electrical equipment and cables likely to be exposed to sustained low
temperatures are to be suitably constructed for the ambient conditions in accordance
with a recognised National or International Standard.