Paragraph 2.1 (paragraph 2.6.2.2 of resolution A.754(18))
“B" class doors should be fire tested in B class steel
bulkheads of dimensions as stated in paragraph
2.4.1 of resolution A.754(18), otherwise approval should be
limited to the type of construction in which the door was tested.
The calcium silicate board described as a dummy specimen
specified in paragraph 3.3 of
resolution A.653(16) should be used as a standard substrate for adhesives.
Paragraph 1.7 of resolution A.754(18)
“B" class constructions should be tested without finishes.
For constructions where this is not possible, finishes should be included
in the non-combustibility test of the construction.
Paragraph 1.2 of resolution A.754(18)
The thickness of insulation on the stiffeners need not be
the same as that of the steel plate.
Paragraph 4.1 of Appendix A.III and paragraph 4.1
of Appendix A.IV of resolution A.754(18)
Penetrations and transits should meet both integrity and
insulation criteria.