See interpretations of regulation II-2/26.2.
A totally enclosed emergency escape trunk belongs to the space category (4). (See also interpretation of regulation II-2/26.2.2(2)).
See interpretations of regulation II-2/26.2.2(8) concerning sauna arrangements, where in interpretation 2 the space categories should be (5), (7) and (10).
1 For the definition of machinery spaces having little or no fire risk in footnote "f", see regulation II-2/26.2.2 (10).
2 Where an asterisk appears in table 27.2, the deck is required to be of steel or other equivalent material but is not required to be of "A" class standard. However, where such a deck, except an open deck, is penetrated for the passage of electric cables, pipes and vent ducts, such penetrations should be made tight to prevent the passage of flame and smoke.
See interpretations of regulation II-2/26.3.