Statutory Documents - MCA Publications - LY3 - The Large Commercial Yacht Code - 15A Fire Appliances - Vessels of Less than 500GT - 15A.2 Specific Requirements - 15A.2.2 Fire pumps

15A.2.2 Fire pumps

  15A.2.2.1 The power driven fire pump should have a capacity of -

where:
L = the length
B = the greatest moulded breadth
D = the moulded depth measured to the bulkhead deck at amidships.

When discharging at full capacity through 2 adjacent fire hydrants, the pump should be capable of maintaining a water pressure of 0.2N/mm2 at any hydrant, provided the fire hose can be effectively controlled at this pressure.

  15A.2.2.2 The second fire pump, which may be portable, should have a capacity of at least 80% of that required by 15A.2.2.1 and be capable of input to the fire main. A permanent sea connection, external to the machinery space, should be provided. "Throw-over" sea suctions are not acceptable.

  15A.2.2.3 Each centrifugal fire pump should be provided with a non-return valve in the connection to the fire main.


Copyright 2020 Clasification Society, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasification Society Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.