Section 10 Plate heat exchangers
Clasification Society 2024 - Version 9.40
Clasifications Register Rules and Regulations - Rules and Regulations for the Classification of Inland Waterways Ships, July 2022 - Part 5 Main and Auxiliary Machinery - Chapter 9 Pressure Vessels other than Boilers - Section 10 Plate heat exchangers

Section 10 Plate heat exchangers

10.1 General

10.1.1 Plate heat exchangers are to be classed as follows. Class 2 where either of the following conditions apply:

  1. the maximum metal design temperature is 150°C, or greater, or

  2. design pressure is 17,2 bar, or greater. Class 3 in all other cases.

10.1.2 Where the design temperature is equal to, or lower than minus 10°C, a higher class is to apply.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.