6.2.1 Provision
                                 is to be made for the capability to blank off temporarily all sea
                                 openings. At Complete Surveys, all openings to the sea are to be examined
                                 together with any valves, cocks and fastenings connected with them.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.2 Where
                                 installed, the following machinery and components are also to be examined:
                              
                              
                              
                              
                                 - 
                                    
                                    
                                    
Engines, air
                                       compressors with their intercoolers, filters and/or oil separators
                                       and safety devices, and all pumps and components used for operational
                                       services.
                                    
                                    
                                    
                                  
                                 - 
                                    
                                    
                                    
Winches and
                                       associated lifting equipment, where fitted.
                                    
                                    
                                    
                                  
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.3 All
                                 air receivers for operational services, where fitted, together with
                                 their mountings, valves and safety devices, are to be cleaned internally
                                 and examined internally and externally. If internal examination of
                                 the air receivers is not practicable, they are to be tested hydraulically
                                 to 1,3 times the working pressure.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.4 The
                                 valves, cocks and strainers of the bilge systems, where fitted, are
                                 to be opened up as considered necessary by the Surveyor and together
                                 with pipes, are to be examined and tested under working conditions.
                                 All safety devices for the foregoing items are to be examined as appropriate.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.5 Hydraulic
                                 oil connections, together with all filters, used for operational services
                                 are to be opened up and examined or tested, as considered necessary
                                 by the Surveyor. All safety devices for the foregoing items are to
                                 be examined as appropriate.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.6 Ballast
                                 connections, together with all filters, used for operational services
                                 are to be opened up and examined or tested, as considered necessary
                                 by the Surveyor. All safety items for the foregoing items are to be
                                 examined as appropriate.
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              6.2.7 All
                                 controls and alarms fitted which are essential for the operation and/or
                                 safety of the linkspan are to be tested to demonstrate that they are
                                 in good working order.