6.1.1 The maximum permitted pressure or vacuum that may occur in the hold space
is to be stated. It is proposed that a value, in accordance with the contents of Pt 3, Ch 1, 9.7 Definitions and details of tests 9.7.4, may be considered as a maximum value. An
overpressure of 0,015 MPa may be used for guidance purposes. If the ventilation system
is capable of producing a positive pressure or vacuum in excess of the design allowable
figure, then means are to be provided to protect the hold space against the effect of
over pressure or vacuum. If axial supply fans are proposed, even if aerofoil fan blades
are fitted, it is unlikely that the fans will be able to produce a pressure above 0,0025
MPa (250 mm water gauge).
6.1.2 If
required, consideration is to be given to the use of a pressure or
vacuum relief device or other arrangement set to operate below the
maximum allowable hold pressure or vacuum.
6.1.3 The
proposed pressure or vacuum relief device for each hold space is to
be of adequate size.