4.3.1 The
gas systems are to be designed so that the pressure which they can
exert on any CA zone will not exceed the design pressure of the zone.
4.3.2 During
initial operation, arrangements are to be made to vent the gas outlets
from each generator to the atmosphere. All vents from gas generators
are to be led to a safe location on the open deck.
4.3.3 Where
gas generators use positive displacement compressors, a pressure relief
device is to be provided to prevent excess pressure being developed
on the discharge side of the compressor.
4.3.4 Suitable
arrangements are to be provided to enable the supply main to be connected
to an external supply.
4.3.5 Where
it is intended that gas systems are to be operated unattended, the
required CA zone environment is to be automatically controlled.
4.3.6 Means
of controlling inadvertent release of nitrogen into CA zones, such
as locked valves, are to be provided.