2.2.1 The
arrangements for collection, handling and transfer of recovered oil
are to be such that the probability of oil spill on deck and overflow
is minimised and the operation is to be performed as far away from
the accommodation spaces as practicable.
2.2.2 In way
of working areas, hand rails and gratings or other non-slip surfaces
are to be provided.
2.2.3 Means
are to be provided to keep deck spills away from the accommodation
and service areas. This may be accomplished by provision of a permanent
continuous coaming not less than 150 mm high.
2.2.4 For assignment of the notations Oil Recovery or Oil Recovery
Ship, at least two portable instruments for measuring flammable vapour
concentrations in air (percentage Lower Explosive Limit (%LEL)) are to be available on
board.