1 This
                           regulation applies to oil tankers of 5,000 tonnes deadweight and above
                           constructed on or after 1 January 2007.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           2 The pump-room shall
                           be provided with a double bottom such that at any cross-section the
                           depth of each double bottom tank or space shall be such that the distance h between the bottom of the pump-room and the ship's base line
                           measured at right angles to the ship's base line is not less than
                           specified below:
                           
                        
                        
                        
                        
                        
                        
                        
                           
                              
                                 | 
                                          
                                       h
                                        | 
                                 = | 
                                 2
                                       m, whichever is the lesser. | 
                              
                           
                         
                        
                        
                        
                        The minimum value of h = 1 m.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           3 In case
                           of pump rooms whose bottom plate is located above the base line by
                           at least the minimum height required in paragraph 2 above (e.g. gondola
                           stern designs), there will be no need for a double bottom construction
                           in way of the pump-room.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           4 Ballast
                           pumps shall be provided with suitable arrangements to ensure efficient
                           suction from double bottom tanks.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           5 Notwithstanding
                           the provisions of paragraphs 2 and 3 above, where the flooding of
                           the pump-room would not render the ballast or cargo pumping system
                           inoperative, a double bottom need not be fitted.