Footnote
Clasification Society 2023 - Version 9.37

Footnote

Refer to the following publication IEC 60529:2003:
  • .1 electrical motors, associated circuits and control components; protected to IPX 7 standard;

  • .2 door position indicators and associated circuit components; protected to IPX 8 standard; and

  • .3 door movement warning signals; protected to IPX 6 standard .

Other arrangements for the enclosures of electrical components may be fitted provided the Administration is satisfied that an equivalent protection is achieved. The water pressure IPX 8 shall be based on the pressure that may occur at the location of the component during flooding for a period of 36 h.

Copyright 2022 Clasification Society Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.