1 Lifeboats and liferafts for which approved launching
                           appliances are required shall be stowed as close to accommodation
                           and service spaces as possible.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           2 Muster stations shall be provided close to the
                           embarkation stations. Each muster station shall have sufficient clear
                           deck space to accommodate all persons assigned to muster at that station,
                           but at least 0.35 m2 per person.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           3 Muster and embarkation stations shall be readily
                           accessible from accommodation and work areas.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           4 Muster and embarkation stations shall be adequately
                           illuminated by lighting supplied from the emergency source of electrical
                           power required by regulation II-1/42 or II-1/43, as appropriate.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           5 Alleyways, stairways and exits giving access to the
                           muster and embarkation stations shall be lighted. Such lighting shall be capable of
                           being supplied by the emergency source of electrical power required by regulation
                              II-1/42 or II-1/43, as appropriate. In addition to and as part of the
                           markings required under regulation II-2/13.3.2.5.1, routes to muster stations shall
                           be indicated with the muster station symbol, intended for that purpose, in accordance
                           with the recommendations of the Organization footnote. 
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           6 Davit-launched and free-fall launched survival
                           craft muster and embarkation stations shall be so arranged as to enable
                           stretcher cases to be placed in survival craft.
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           7 An embarkation ladder complying with the requirements
                           of paragraph 6.1.6 of the Code extending, in a single length, from
                           the deck to the waterline in the lightest seagoing condition under
                           all conditions of trim of up to 10° and a list of up to 20°
                           either way shall be provided at each embarkation station or at every
                           two adjacent embarkation stations for survival craft launched down
                           the side of the ship. However, the Administration may permit such
                           ladders to be replaced by approved devices to afford access to the
                           survival craft when waterborne, provided that there shall be at least
                           one embarkation ladder on each side of the ship. Other means of embarkation
                           enabling descent to the water in a controlled manner may be permitted
                           for the liferafts required by regulation
                              31.1.4.
                           
                        
                        
                        
                      
                     
                     
                     
                        
                        
                         
                           8 Where necessary, means shall be provided for
                           bringing the davit-launched survival craft against the ship's side
                           and holding them alongside so that persons can be safely embarked.