10.1.1 Fusion
welded pressure vessels are to be tested on completion to a pressure, p
T, determined by the following formula, without
showing signs of weakness or defect:
but in no case is to exceed
where
p
|
= |
design pressure, in MPa |
pT
|
= |
test pressure, in MPa |
t
|
= |
nominal
thickness of shell as indicated on the plan, in mm |
σ
T
|
= |
allowable stress at design temperature, in N/mm2
|
σ
50
|
= |
allowable stress at 50oC, in N/mm2.
|