8.2.1 Each
                                 type of power unit pump is to be subjected to a type test. The type
                                 test is to be for a duration of not less than 100 hours, the test
                                 arrangements are to be such that the pump may run in idling conditions,
                                 and at maximum delivery capacity at maximum working pressure. During
                                 the test, idling periods are to be alternated with periods at maximum
                                 delivery capacity at maximum working pressure. The passage from one
                                 condition to another should occur at least as quickly as on board.
                                 During the whole test no abnormal heating, excessive vibration or
                                 other irregularities are permitted. After the test, the pump is to
                                 be opened out and inspected. Type tests may be waived for a power
                                 unit which has been proven to be reliable in marine service.