Greece - Specific requirements by the Greek Administration
Flag instructions relating to Statutory surveys
Flag procedural requirements
| Standing requirements | Action by |
|---|---|
| 1- Reporting on entry into Class | MOC |
| 2- Reporting on requests for exemptions or interpretations | MOC |
| 3- Reporting on cases of major deficiencies, as per IACS Recommendation 98 (Duties of Surveyors under Statutory Conventions and Codes) | MOC |
| 4- Pre-authorisation prior to extending Statutory certificates | MOC |
| 5- Pre-authorisation prior to issuing conditional certificates | MOC |
| 6- Reporting on detentions | DO-FM |
| 7- Submission of copies of Statutory certificates | DO-FM |
| 8- Reporting on Class suspension or Class modification | MOC |
| 9- Reporting on Class withdrawal | DO-FM |
General Policy
Agreement
An Agreement has been signed on 02 April 2026 between the Government of the Hellenic Republic and Recognised Organisation (RO) SA. It enters into force on 11 April 2026 with four-year validity.
The paragraph 3.16 in the Agreement, is as follows (see Agreement governing the Delegation of Certification Services): «3.16. The RO is entitled to issue certificates/ documents covered by the Agreement only for ships classed by the authorized RO. This limitation does not necessarily apply for statutory certificates/documents/studies/plans issued/approved according to the provisions of the ISM Code, the ISPS Code, and Regulation (EU) No 1257/2013 of the European Parliament and of the Council of 20 November 2013 on ship recycling. It does not also necessarily apply for documents/studies/plans verified/approved/issued according to requirements of the Data Collection System for Fuel Oil Consumption of ships as well as requirements of the International Energy Efficiency Certificate of MARPOL Annex VI.»
(Letter 2311.1-14/40769/2023 see Agreement governing the Delegation of Certification Services) The possibility is provided for an RO, and for vessels that are not under its classification, to verify/ approve/ issue documents/ studies/ plans related to the International Energy Efficiency Certificate of Annex VI of the MARPOL International Convention. The general, however, limitation of paragraph 3.16 continues to apply regarding the issuance of the Energy Efficiency Certificate, which is normally carried out by the statutory certification body of each ship.
The Agreement and its Appendices 1 and 2 show the details of authorization granted (see Agreement governing the Delegation of Certification Services to Appendix 2 to the Agreement).
Information to Piraeus Marine Center
Piraeus Marine Center is to be informed for any Statutory survey request on ships flying the Greek Flag for possible compliance with National Requirements in addition to those foreseen by SOLAS and relevant International Conventions.
Interpretations, Equivalents and Exemptions
Interpretations of the applicable instruments, as well as the determination of equivalents or the acceptance of substitutes to the requirements of the applicable instruments are the prerogative of the Administration. Recognised Organisation (RO) may however contribute to their establishment, if so requested by the Administration. Tacit acceptance or any acceptance procedure other than the one explicitly defined by the Administration is not admissible.
With respect to IACS Unified Interpretations on the above mentioned subjects, a specific approval procedure by the Administration shall apply.
Exemptions from the requirements of the applicable instruments are the prerogative of the Administration and must be initially approved by the Administration prior to issuance by Recognised Organisation (RO) of an exemption certificate for a specific ship. Renewals of exemption certificates are not required to be re-approved by the Administration, provided that there have been no changes affecting either directly or indirectly conditions taken into consideration for the initial exemption issued.
In cases where, temporarily, full compliance with an applicable instrument cannot be met, the Recognised Organisation (RO) surveyor shall specify, per case, such measures or supplementary equipment to permit the vessel to proceed with safety to a suitable port where permanent repairs or rectifications can be effected or replacement equipment fitted.
Recognised Organisation (RO) shall, without delay, submit to the Administration a written and adequately justified report, stating the subject of the non compliance, proposed measures or/and supplementary equipment, the deadline for rectification as well as the intended port of call where rectification shall be effected, so that they are approved by the Administration.
The Administration shall respond to a justified request the soonest possible, within a 24- hour period after the receipt of the respective report, except for extraordinary cases, where more time is required to evaluate the request or the Administration is objectively unable to respond within the 24 hour period.
In case of approval, after Recognised Organisation (RO) has ensured that all approved conditions are met, Recognised Organisation (RO) shall issue a limited validity Attestation for statutory recommendations (available in ASMS2 / National Certificate), which along with the Administration’s approval document shall be attached to the ship’s affected certificates. The Attestation shall state, in the form of conditions laid down, current non compliances, the approved measures and supplementary equipment as explained above (statutory recommendations). It shall also explicitly state the deadline for rectification as well as the intended port of call where rectification shall be effected.
A copy of this Attestation is communicated to the Administration.
Exemption certificate
For the initial issuance of an exemption certificate, in all cases, the Administration requires authorization. The request shall reference the regulations of the international conventions that are applicable and whether the conditions, if any, of those regulations are satisfied. The Surveyor shall contact the Administration via MOC Piraeus. In cases where the authorization from the Administration is not available at the time of survey, an initial exemption certificate is not to be issued.
For the renewal/re-issuance of an exemption certificate authorization from the Administration is not required, provided that the conditions (if any), on which the initial exemption certificate was issued, are satisfied.
If the conditions on which the initial exemption certificate was issued are not satisfied, then the Surveyor shall contact the Administration through the MOC Piraeus for a ruling on issuance and term of validity of an authorized Short Term Exemption Certificate.
When a short term SOLAS certificate is issued for deficiencies not directly related to the provisions (if any) on which the exemption certificate(s) attached to that certificate was (were) issued, then any exemption certificate(s) attached to that short term SOLAS certificate may be issued as a short term without authorization from the Administration.
(Refer to the GREEK FSA Letter No: 2311.1-14/74189/2025 in attached file “2311.1-14_74189_2025_Requests for the provision of permanent exemptions”)
For the provision of permanent exemptions, exemptions and equivalences for ships flying the Greek flag, it is deemed necessary from now on to notify these requests to the email address dkc@hcg.gr.
Request for temporary exemption
(Refer to Greek FSA Letter No: 2070.0/27780/2022, dated 19/4/2022, regarding standardization of the mode for submitting requests for temporary exemptions of Greek ships from requirements of applicable instruments by authorized ROs in attached files)
By means of the provisions on the applicable process set out in para 3.1 of the Greek FSA Letter No: 2070.0/27780/2022, the competent authority mandates that henceforward all requests for exemptions from applicable requirements are to be sent by Recognised Organisation (RO) in a certain standardized bilingual format subjected to the model notification contained in Annex I to the aforesaid letter (see p. 3/13) by means of an email addressed to kep@hcg.gr bearing the characteristic title: “Damage”, or: “Failure”, or: “Malfunction”, or: “Non Compliance”, as might be the reported case respectively.
Each such electronic request has to be complemented by the following:
A sufficiently documented Recognised Organisation (RO)’s proposal on the nature of the existing non-compliance on-board, the proposed additional measures for adequately addressing the issue in the short run as well as the proposed limit date for rectification and the port of permanent repair / replacement.
Master’s statement that the crew has been duly informed and is well aware about the proper management of the temporary measures- extraordinarily met on-board in this regard - as well as on likely effects on the ship’s safe operation.
Master’s declaration that inoperative equipment has been properly marked (for obvious safety reasons).
The Administration has to reply with 24 hours at the latest upon receiving the Recognised Organisation (RO)’s proposal.
Starting from February 1, 2023, onwards, the Administration will issue periodically a cumulative list comprising frequently recurring requests for exemptions from international instruments such as: COLREG, SOLAS, MARPOL and BWMC requirements; as the one paradigmatically attached in Annex II to the aforesaid letter which outlines equivalent measures and the corresponding preconditions for the latter’s acceptance by the Administration.
Guidance on technical requirements and “to the satisfaction of the Administration”
(Circular 2324.8/77884/2025 in attached file “Circular_2324.8-77884_2025 - Guidance on technical requirements”)
This circular provides individual technical instructions for the uniform implementation of the provisions of the mandatory IMO instruments on ships flying the Greek flag.
This circular also provides interpretative provisions for the application of the regulations of the mandatory IMO bodies defined by the term “to the satisfaction of the Administration”, as established in accordance with the national, EU and international framework (laws, presidential decrees, ministerial decisions, European regulations, directives and circulars).The requirements of the Administration are described in the Annex to this circular.
The Annex does not include all identified requirements with the indication “to the satisfaction of the Administration” or equivalent, but only those for which the Administration has already regulated through legislation (law, presidential decree, ministerial decision, EU regulation, directive or circular). Other relevant requirements fall under the case-by-case examination as described in this circular.
Change to the Greek flag
New certificates may be issued with, at most, the same validity as the certificates issued under the previous Flag Administration if:
the former certificates have been issued by the Flag Administration, a Classification Society or technical company recognised by Greece, and
the ship's condition corresponds to what is indicated on the certificates.
To check this last requirement, as a minimum, a general inspection is required.
On the other hand, all necessary Recognised Organisation (RO) records shall be put on board.
Information of the Administration
The list of ships for which a new situation has been set is sent to the Administration by the MOC.
MOC Piraeus is to provide copies of process Instructions and Interpretations Instructions relevant to Statutory Surveys to the MSI.
Interested parties (i.e. Flag Administration, Owners / Operators, and, where practicable, the Master of the vessel and Local Port Authorities) should be notified in case of expiration of Statutory certificates.
Report Distribution / Copies of Certificates
Upon completion of all statutory surveys, attending office shall send to the Administration, via MOC Piraeus, copies of the statutory reports. For issuance of initial statutory certificates, full-term certificates, exemption certificates; renews a statutory certificate or extends same by the head office on behalf of Hellenic flag Administration; copies of these certificates shall be sent to the Hellenic Authorities through the MOC Piraeus.
Use of Non-Exclusive Surveyors
Article 7.4 of the Agreement states that statutory surveys shall be carried out or directly supervised by Exclusive Surveyors to Recognised Organisation (RO).
Under exceptional circumstances and with the approval of the Administration, Non-Exclusive Surveyors may conduct surveys on Greek ships provided that they are subjected to the Society's Quality System, i.e. they fulfill the Society's Surveyor Certification Scheme.
Recognised Organisation (RO) position: Surveys of Greek ships are carried out by Exclusive Surveyors. If no Exclusive Surveyor is available and if it is intended to commit a Non-Exclusive Surveyor, the SSQM shall report to MOC Piraeus which will then contact the Administration.
The following data shall be forwarded to MOC Piraeus:
Name and Register Number of the ship,
Survey(s) expected to be carried out,
Non-Exclusive Surveyor's name and qualification according to the Certification Scheme.
Delegation for passenger ships
The Society is now authorised to survey and issue Statutory certificates to passenger ships whatever their tonnage.
The Society is fully authorised to survey and issue Statutory certificates to passenger HSC and passenger DSC.
Issuance of certificates
If Recognised Organisation (RO) is to issue certificates to a vessel where the certificates were previously issued by the Administration, then the Administration is to be notified (via the contact office), indicating the vessel's details and the certificates to be issued. Any overdue outstandings made by the Administration against the certificate are to be rectified prior to Recognised Organisation (RO)'s issuance of the certificate. The validity of the new certificate is to be based on the existing certificate.
Class suspension, withdrawal of certificates
In cases where a certificate is withdrawn, the Surveyor shall give a letter to the Master of the vessel stating that the certificate is withdrawn from the date of signature of the letter and request that the certificate in question be surrendered.
A copy of the letter shall be sent to the Administration immediately by the most expedient means possible. If the ship is in a port of another State, the Surveyor shall ensure that the Port State has been notified.
Detention - Action to be taken during Port State Control
The Surveyor shall contact the Administration through the MOC Piraeus when a Greek vessel has been detained during port state control. Details of the survey and survey status are to be provided to the Administration in the event that Recognised Organisation (RO) is requested to take action during port state control.
In all cases (whether requested by the Owner or not), upon notification that a vessel has been detained, Recognised Organisation (RO) is to attend the vessel, either at the port of detention, or if not possible, then at the next port, and verify that all deficiencies have been rectified. The Administration is to be notified of the results of the attendance and a concise report on the results of the internal investigation of the detention is to be established.
Detainment twice within 12 months
If a Greek flag ship is justifiably detained twice within 12 months, then the RO certifying the ship according to ISM Code shall inform the Administration and shall conduct an additional shipboard audit in the scope of an intermediate audit at the most convenient port of call within 3 months from the second release from detention and the RO certifying the managing company of the ship according to the same Code (ISM) shall conduct and additional audit of the company in the scope of an annual audit the soonest possible and not later than 3 months after the ship’s second release from detention.Ship Inspection General Directorate may attend during all the above stages with a team of surveyors/auditors at discretion.
Detainment three times within 24 months
If the same ship is justifiably detained three times within 24 months, the RO certifying the ship according to ISM Code shall withdraw the Safety Management Certificate until satisfactory completion of an additional audit on board the ship in the scope of an initial audit. Additionally, the RO certifying the company shall carry out an additional audit in the scope of an annual audit within a month’s period from the date of the last reported detention. Ship Inspection General Directorate may attend during all the above stages with a team of surveyors/auditors.
Extention of SOLAS Certificates
When a Surveyor is authorized by the Administration to extend the validity of a SOLAS Certificate, the Administration has requested the following procedure to be used:
Do not remove the existing on board Certificate.
Endorse the existing certificate as follows: “The validity of this certificate is extended until (date) pending completion of renewal survey”.
Sign, date and stamp the above endorsement.
Notify MOC Piraeus by fax, immediately.
The Administration has authorized Recognised Organisation (RO) to extend the validity of Harmonized SOLAS 88 Protocol certificates for a period not exceeding 3 months from their expiry date, as foreseen by SOLAS Regulation I-14(e). The extensions may be granted, in accordance with the provisions of subject regulations, provided that from relevant surveys and records kept, the Recognised Organisation (RO) determines that there are no outstandings affecting the safety of the vessel and the protection of the environment, and that the vessel is considered fit for the intended service for the duration of the extension period.
The extension of a short term certificate requires authorization from the Administration.
Extension of Certificates in case of “force majeure”
(Normative Ref.: Law No: 4757/2020 (Governmental Gazette No.: A’240))
Pursuant to the provisions set out in Article 76 of the above referenced national legal instrument, the extension of the statutory certificates’ validity for a period of up to four (4) months is possible by making use of suitable remote inspection techniques (RIT) with satisfactory results and upon the authorized RO’s timely & documented proposal to the competent FSA.
Outstanding deficiencies
When major deficiencies cannot be corrected at the time of the survey (such as unusable lifeboats, inoperative fire pumps or fixed extinguishing systems), the Surveyor shall contact the Administration (MSI) through the MOC Piraeus for a ruling on issuance and term of validity of an authorized Short Term Certificate. The Surveyor shall provide the MOC Piraeus with full details of the major deficiencies found. However, if warranted, the Surveyor shall remove the appropriate certificate prior to contacting the Administration for a ruling.
Change of registry
Any additional requirements, tests and/or inspections required under Greek regulations that were not required for certificates under a previous flag may be postponed for a more convenient period such as the next Annual, Intermediate or Periodical survey. In any case, the Administration shall be contacted for instructions via the MOC Piraeus.
Whenever a request for classification of a ship that will be or has been registered in the Greek Register is received, the Administration shall be immediately informed through the MOC Piraeus.
Reporting to the Authorities
Recognised Organisation (RO) shall promptly inform the Administration when a ship is found to be in operation with such deficiencies or deviations that the ship’s condition or its equipment does not substantially correspond with the particulars of its certificates or the requirements of applicable International Conventions or European Union and National regulations so that, in the opinion of Recognised Organisation (RO), the ship is not fit to proceed to sea without danger to the ship, persons on board, or presenting an unreasonable threat of harm to the environment.
Furthermore, if corrective action is not taken to the satisfaction of Recognised Organisation (RO), then Recognised Organisation (RO) shall withdraw the relevant certificates and inform the Administration and the master of the ship via the ship’s owing/managing company respectively.
Statistical data on ships flying the Greek flag
Pursuant to the provisions of paragraph 4 of Annex 2 to the Agreement (see Appendix 2 to the Agreement) Recognised Organisation (RO) is obliged to periodically submit Greek flag ships’ statistical data to the Administration.
The authentic administration letter, along with the corresponding reporting template are in attached files “Authentic GR Letter” and “Reporting Template”.
LL 66
Loadline Certificate
Scope
Recognised Organisation (RO) has been authorized by the Administration to conduct on Greek Flag cargo and passenger ships classed with Recognised Organisation (RO) those surveys required by the International Convention on Load Lines 1966 and 1988 Protocol, and to issue the relevant certificate.
Procedures
The Hellenic Authorities have requested that each time a ship of Greek flag changes from open to closed shelter deck condition or vice versa, they be advised. This shall be accomplished by forwarding a message to MOC Piraeus including name of ship and date of change as well as information necessary to indicate the ship's past and present condition. This advice should be sent as soon as possible after the changeover.
The Hellenic government has given blanket authorization for Multiple Load Line Assignments,provided the following procedure is followed:
The ship complies with all the provisions of the ILLC, 1966, regarding the maximum permissible draught which corresponds to the minimum freeboard. The said draught will also be taken into account when issuing the ship's Tonnage Certificate in accordance with ITC69.
The ship's load lines, which correspond to the certificates issued, are permanently marked onto the sides of the ship (in relief or chiseled) and Recognised Organisation (RO) conducts the initial survey.
Only one load line is to be painted-in at a time, corresponding to the certificate being used. Any other Load Line Certificate is to be kept separately by the Captain.
In all cases, the Captain is to summon an Exclusive surveyor in order to check that the particular Load Line is correctly used in combination with the corresponding Load Line Certificate.
In the event that in the particular place where a different load line is being used, and a Surveyor is not able to confirm the change, then this is to be recorded in the ship's log by the Captain. A surveyor is then to be summoned at the ship's next port of approach to verify the change.
The ship's Stability and Trim Booklet is to include loading conditions corresponding to the dead weight for each of Load Line Certificates that have been issued.
In addition to the Load Line Certificates, Recognised Organisation (RO) is to issue an equal number of supplements to the IOPP, corresponding to each deadweight. Additionally, a full set of SOLAS certificates for each deadweight value should be issued.
After issuance of multiple load line certificates, the relevant department of the Hellenic Flag (ΥΕΝ/ΚΕΕΠ/ΔΜΚ/ΝΚΜΚ) shall be informed about the number of certificates issued and their relevant data (freeboard and DWT). The attending surveyors have to inform MOC Piraeus as soon as the certificates are issued.
The Administration has authorized Recognised Organisation (RO) to extend the validity of Harmonized Loadline 88 Protocol certificates, for a period not exceeding 3 months from their expiry date, as foreseen by Loadline 88 Protocol Article 19/5. The extensions may be granted in accordance with the provisions of subject regulations, provided that from relevant surveys and records kept, Recognised Organisation (RO) determines that there are no Outstandings affecting the safety of the vessel and the protection of the environment, and that the vessel is considered fit for the intended service for the duration of the extension period.
The extension to the certificate may be in a form of telex or fax to the vessel’s master with copy the MSI and the owners. A Recognised Organisation (RO) Surveyor shall endorse the extended certificates for the extensions at the first port of call were attendance is practicable.
Trim & Stability Booklet Approval
After completion of the trim and stability booklet review, a copy of the approved booklet is to be forwarded to the administration, through MOC Piraeus, along with a copy of the approval letter.
The approval letter is to indicate, in addition to the usual approval wording, that the booklet, containing the pertinent trim and stability calculations, is “in compliance with Greek legislation”.
For ships in service under foreign flags entering the Greek Register, the existing booklet is to be reviewed by Recognised Organisation (RO) and stamped as stated above. In all cases a copy of the relevant trim and stability data and calculations should be kept onboard for the master's use. For any type of ship engaged exclusively in domestic trade, the aforementioned data should be compiled in the Greek language.
In cases of transfer of class from another IACS organization, Recognised Organisation (RO) shall take note of the ship’s stability data files and review/approve the ship’s stability booklet as appropriate, according to our internal procedures, and the letter as indicated in paragraph a) above is still to be issued.
SOLAS 74
Cargo Ship Safety Construction Certificate
Corrosion Prevention of sea water ballast tanks
(SOLAS, Reg.II-1/3-2.2) (fax 230858/11-99)
Although not compulsory, the use of light colour coatings in the ballast water tanks is recommended to enable the easy and immediate detection of cracks and corrosions.
SOLAS II-1/3-2 (IMO PSPC) - Delay in delivery of ships
(Email from Recognised Organisation (RO) Greece dated 10th July 2012)
Refer to free translation of Circular from Administration, dated 6th July 2012 (ref: 4200/146/12), as per attached file “MSIGD_PSPC_06072012”.
Lifting Appliances and Anchor Handling Winches
(Greek Flag Circular No 2070.0/30712/2026)
For the application of Regulation 3-13/1.3 of Part A-1 of Chapter II-1 of the International SOLAS Convention, lifting appliances with a safe working load of less than 1,000 kg installed before, on, or after January 1, 2026, are not required to comply with the requirements of paragraphs 2.1 and 2.4 of Reg. II-1/3-13; however, they must comply with the following:
Bear a clearly visible permanent marking and documentary evidence of the Safe Working Load (SWL) and a test certificate from the manufacturer, prior to their installation on board the ship.
Follow, as a minimum, the manufacturer's inspection and maintenance instructions and requirements.
The managing company must incorporate procedures into the Safety Management System (SMS) for the inspection, maintenance, as well as the training/familiarization of the crew regarding the inspection, maintenance, and use of the stated lifting appliances.
For all other matters, the provisions of Presidential Decree 316/25-9-01 on the “Regulation for the inspection of ship lifting appliances” (A' 212) remain in force and are not amended, repealed, or replaced by this circular (see Cargo Gear Surveys).
Refer to free translation of Circular No 2070.0/30712/2026 from Administration, dated 6th May 2026 as per attached file “Circular 2070.0-30712-2026_OLAW”.
Cargo Ship Safety Equipment Certificate
Magnetic Compass Calibration
When the period since the last Magnetic Compass calibration exceeds 12 months and no other deficiencies are found, the Safety Equipment certificate should be issued valid “to the next port of call” or for a period not exceeding 1 month from date of survey, pending rectification of the deficiency.
(Administration letter 2333.5-4/66038/2026 in attached file “9Χ2Φ4653ΠΩ-ΒΛΠ - Magnetic Compass adjustment”)
Only persons registered in the active register of commercial ship magnetic compass adjusters posted on the website of the Ministry of Maritime Affairs and Insular Policy are authorized to adjust the magnetic compasses of Greek commercial ships and to issue deviation tables.
Drills and Inspection of Lifeboats and Associated Equipment
The following should be verified:
All lifeboat and associated equipment inspections, maintenance and repairs are properly carried out by personnel fully-trained, familiar with these duties, and appropriately qualified.
All appropriate documentation for the maintenance and adjustment of lifeboats, launching appliances, and associated equipment is available on board.
Maintenance of lifeboats, launching appliances, and associated equipment is carried out in accordance with approved established procedures.
Lifeboat drills are conducted in accordance with SOLAS Regulation III/19.3.3, for the purpose of ensuring that ship's personnel will be able to safely embark and launch lifeboats in an emergency, especially with regard to the use of on-off load release gear, where operating instructions must be strictly adhered to.
Equipment is easily accessible for inspections and maintenance.
Requirements for maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances and release gear (MSC 402(96))
(Greek FSA’s circular Ref. No: 2333.2-14/13767/2020)
Following IMO Resolution MSC.402(96), the Administration has issued the below clarifications.
QUOTE
4. Specifically:
In connection with paragraph 7.2 of MSC.402(96):
the authorized ROs are obliged to submit to this Administration electronically at: mareq@hcg.gr the attestations issued to service providers based in Greece, in order for these information to be included and periodically updated in the public domain of the Administration’s website.
In connection with paragraph 7.3 of MSC.402(96) and for equipment:
- for which the maker seized supporting it, or if
- no appropriately authorized service provider exists in the country where the ship operates (justification on the latter to be provided by care of the ship’s managers, or the RO, in cases where the classing RO provides full statutory certification services to the vessel), or
- in case where, for the annual equipment’s testing, the authorized service supplier had timely declared inability to provide the required services, i.e. at least one month prior to the due date, or if,
- in instances of defective equipment, the authorized service provider declares in writing the reasons for not being able to provide the necessary repair work and the operational checks & tests of the equipment,
then, the works related to the provisions of MSC.402 (96) can be assumed by service providers holding approval certificates issued by any maker of this very kind of equipment and who had been approved of by this Administration on the basis of these approvals. For ships operated abroad, the same applies for service providers being analogously authorized by any other IMO member State and/or ROs.
As regards paragraph 7.4.3 of MSC.402(96)
For lifesaving appliances on internationally trading ships, this Administration will accept utilization of service providers appropriately certified by IMO member States, or holding approvals by ROs subjected to Regulation (EC) 391/2009, provided that the requirements set out in MSC.402 (96) are fully met.
5. Service providers holding authorizations issued by this Administration prior to 01/01/2020 shall ensure that the initial inspection i.a.w. par 7.4 of MSC.402 (96) takes place in order to be furnished with the initial attestation / authorization issued by the Administration, as required. Specifically the following should be noted:
The service provider to follow a Quality System pursuant to provisions of section 7 of MSC.402 (96).
Certification by the makers of the technical staff of the service provider for each kind of equipment (e.g. life boat, rescue boat) and for each type foreseen by the maker, wherein specific reference is to be made that the document at hand had been issued i.a.w. the requirements of MSC.402(96). By means of this requirement, which applies by virtue of para 8.3.1 of the aforesaid resolution, the training requirements, as contained in section 8, are essentially covered.
6. The new attestations that will be issued after the initial inspection (para 7.4 of MSC.402 (96)) shall at least comprise the following:
The Service Provider’s Full Style Address & Contact Details
An attestation on the verification that the requirements set out in MSC.402(96) were fulfilled
The expiry date of the attestation which cannot exceed five years; with a note for a mandatory intermediate periodic inspection.
The obligation of the service provider to adhere to the preconditions for the attestation’s issuance, so as for the later to retain its validity.
A table (Annex) with all names of the technical staff and the corresponding certificates of each and every one without for limit dates to be mentioned; however, it is the obligation of the service provider, to inform the issuer of the Attestation for any changes.
7. Regardless of the requirements of the authorized ROs (UR Z17 as in force), the inspections and the issuance of the aforesaid attestations for service providers located in Greece -as per the above para 4a) -shall be conducted by this Administration.
8. Existing attestations issued by either the FSA or the authorized ROs can be used by 30/06/2020 at the latest, provided that the service providers concerned hold written certifications issued in the context of para 5b above.
9. All parties concerned are requested to undertake the necessary to the extent required
10. Port authorities and maritime attachés abroad are requested to exert the controls foreseen by the above provisions.
UNQUOTE
For further information, refer to attached file “Greek FSA on the Certification of Service Providers.pdf”.
Lifeboat and Liferaft Supplies
The pharmaceutical and sanitary supplies in the medicine kits of lifeboats and liferafts must be approved by the Hellenic National Organization for Medicines (EOF). If a vessel is not located in Greece at the time of expiration of any of these supplies, the supplies may be replaced by supplies approved by their country of origin. However, these supplies must be replaced with EOF-approved supplies as soon as possible.
Liferafts, Hydrostatic Release Mechanisms, and Marine Evacuation Systems (MES) Servicing
Untitled
The Administration has issued instructions dated 10 February 2000 that contain the requirements for servicing stations located in Greece servicing liferafts, hydrostatic release mechanisms, and MES to obtain a license. This equipment, onboard Greek-flagged vessels, when serviced in Greece, is to be serviced by an appropriately licensed service station. A list of approved service stations Greece is issued by the M.S.I. bi-annually.
At this time, the Administration is accepting servicing stations outside of Greece approved by local Flag Administrations (signatory to SOLAS) or by Organizations recognized/approved by local Flag Administrations. The liferafts, hydrostatic release mechanisms (except of one-use disposable ones, which have an expiry date), and MES equipment is to be tested every 12 months. Any gas cylinders that are part of the liferaft or MES are to be hydraulically tested every 5 years starting from the date of manufacture or previous service. Any liferaft supplies with an expiration date within 6 months of the annual inspection are to be replaced at the time of inspection.
The Administration requires (in addition to the last annual inspection date of a liferaft's hydrostatic release mechanism and MES equipment) that thename of the approved external specialist firm carrying out the inspection be recorded on the remarks section of the safety equipment check sheet, to ensure this information is available on request.
For liferafts on ro-ro passenger ships, the liferaft(s) that carry the SART is/are to be marked as follows: “RADAR Transponder is fitted”.
Lead Sealing
In order to ensure an unimpeachable inspection quality of the life raft until its next inspection, it is necessary that the competent service station uses lead seal.
If the equipment cannot be serviced within the 12-month period, an extension may be granted of up to 5 months from the date of expiry of the equipment inspection certificate, only in the following cases:
Either the ship has to depart urgently or there is not an authorized service station in the immediate area, or;
The period of time until the due date of the Safety Equipment certificate is short and the vessel's master intends to proceed with renewal of the ship's SLE certificate and the equipment annual inspection. In addition the equipment is to be visually verified in good condition. A related statement by the vessel's master can be considered as sufficient evidence, in situations where the Surveyor's attendance is difficult or impractical. The above extension can be granted by the contact office without prior approval by the Administration, however the Administration is to be immediately notified via the contact office, and ship’s Master be advised accordingly in writing.
Extensions of validity of inspection certificates for inflatable liferafts and Marine-type Evacuation Systems on passenger ships
Refer to Circular 2322.1/48690/2025 in attached file “Circular 2322.1_48690_2025_LSA, MES postponement”.
Additional Lifejackets for Cargo Ships
The Administration advises that the additional lifejackets required per Regulation III/7.2.1.2 of SOLAS 1974, as Amended (this requirement applies to vessels with keel laid after 1 July 1986) must be provided as follows:
For crew members on watch, four lifejackets if the crew is not more than 16 person, or 25% of the size of the crew when the crew is more than 16 persons. Lifejackets must be distributed to the bridge and engine control room and must be placed in highly visible locations with appropriate markings.
In the vicinity of any liferaft in remote areas of the vessel (which is required in accordance with regulation III/26.1.4 or III/26.3.2 of SOLAS 1974 as amended), at least six (6) lifejackets shall be placed in a highly visible area that is protected from moisture, and these areas shall have appropriate markings.
Immersion Suits and Anti-exposure Suits
IMO has issued MSC/Circ.1047 guidelines for the monthly shipboard inspection and maintenance of immersion suits and anti-exposure suits. The Administration's circular 4339.20/03/02 requires the ship's crew to follow these and manufacturer's instructions when carrying out these inspections and maintenance. In this regard, during the SLE Survey, it is to be “checked” that these monthly activities have been carried out. The Administration has advised that exemption from the carriage of immersion suits is granted for vessels that undertake the following voyages:
Within the Mediterranean and Caribbean Seas, only for the period between 1 April and 30 October.
In the Persian Gulf, the Red Sea and the area between the parallels of latitude 20° N and 20° S, throughout the year.
The Administration has also advised that, when amended SOLAS regulation III/32.3.3 comes into affect on 1 July 2006, the number of additional immersion suits are to be determined on a case-by-case basis, considering such things as the distance between the ship's control station and life saving equipment, problems with stowing immersion suits on deck where there is no control station, etc.
Fire Pumps / Fire Line
The fuel for internal combustion engines that drive fire pumps should have a flash point of not less than 60O C (diesel oil).
For vessel’s built on or after 4 February 1997, the fire main and branches should not be constructed from cast iron. If the line and branches are constructed from iron or steel, they should be galvanized. The prohibition of cast iron and the requirement of galvanizing iron or steel parts of the fire line also apply to various fire line components (valves and fittings).
For vessel’s built on or after 4 February 1997, which are currently under another flag and are changing flag to Greece, and are not complying with the above requirements, are eligible for an exemption. Applications are to be submitted to the MSI for their consideration, via the MOC Piraeus. MSI recommends color marking of the main fire line and branches with red color, as specified in ISO 14726 standard, without same to be considered as a mandatory requirement.
MSI has clarified that they do not encourage the connection of the fire main line to services other than fire fighting, except for deck washing and chain washing. The Greek MSI has accepted connections of the fire main to other services provided that the isolation valves on the branches from the fire main are operable also from outside the spaces where the valves are installed. Furthermore, the MSI has advised that in cases where a general service or bilge pump is also used also as a fire pump, the main line connected to the first hydrant branch is considered the fire main.
Alternative Means of Providing Water for Firefighting Purposes
(Regulation II-2/4.3.3.3 of SOLAS 1974, as amended)
The Greek Administration has advised that for vessels less than 1000 gross tons, no alternative means for fire-fighting purposes are required in the case where fire pumps have been placed out of order. For vessels between 1000 and 2000 gross tons, the alternative means for firefighting purposes can be a fixed fire extinguishing system protecting the fire pump space.
Fixed Fire-extinguishing Systems
For cargo vessels, the fixed fire-extinguishing systems should be inspected every 2 years and during the safety equipment renewal surveys, by an approved service station. A record of the bi-annual check and date should be legibly marked on each cylinder/container.
The Administration advises that if the fixed fire extinguishing system manufacturer specifies shorter inspection intervals or other more stringent requirements, then the manufacturer recommendations should prevail. The installation of new Halon systems is not allowed on Greek flag ships built on or after 4 February 1997.
For CO2 systems, provided that bi-annual inspections are carried out, all cylinders are to be hydraulically tested every 10 years starting from their date of manufacture or the previous hydraulic test for the first 20 years, then every 5 years thereafter. The cylinders shall be hydraulically tested at a pressure that exceeds the maximum working pressure as set by the manufacturer or the pressure of 250 bar, whichever is higher.
Any cylinder that has been discharged, or that has shown 10% loss of the original weight as stamped on the cylinder, or externally found excessively corroded shall be hydraulically tested.
The pressure and date of the hydraulic testing must be permanently inscribed on the body of each cylinder / container.
Records of the inspection and tests of the cylinders are to be maintained onboard the vessel.
The Administration has advised that, until further notice, fire extinguisher service stations, which have been approved by Recognised Organisation (RO) in accordance with the external specialist approval program and IACS UR Z17 or the local Flag Administration (signatory to SOLAS’74) are acceptable.
The Administration requires, in addition to the last biannual inspection date of the installation, that name of the approved external specialist firm carrying out the inspection be recorded on the remarks section of the safety equipment check sheet, so that it can be made available on request.
Portable Fire Extinguishers
Portable fluid fire extinguishers should contain fire-extinguishing medium not more than 13.5 liters and not less than 9 liters. The weight of the content of the carbon dioxide fire extinguishers should be at least five (5) kilograms. The weight of the content of the dry powder fire extinguishers should be at least five (5) kilograms.
For portable fire extinguishers capable of being recharged onboard, 50% spare charges are required.
For portable fire extinguishers not capable of being recharged onboard, 50% spare portable fire extinguishers are required. However, the number of these spare extinguishers is not required to exceed 20.
The MSI has advised the following data are required to be marked on portable fire extinguishers:
The manufacturer shall engrave on the container the year of construction; the serial number; and the testing pressure (e.g. 25 bar) and label the trade mark or title of the firm.
A label shall be glued on the container of the fire extinguisher, by the manufacturer or servicing station, which states the following:
The characterization of the extinguisher (e.g. dry powder type, 12 kg).
The type (e.g. P12)
The phrase "Refill After Use"
Directions for the use of the fire extinguisher.
The categories of fire (A, B, C, D, and E) and their symbols with a brief clarification for which category the fire extinguisher is suitable.
The fire extinguishing ability.
For water and foam fire extinguishers, the solidification temperature (e.g. suitable up to +1°C).
If it is not suitable for electric current, then the statement “NOT SUITABLE FOR ELECTRIC CURRENT”, shall appear.
If it is suitable for electric current, then the statement “SUITABLE FOR ELECTRIC CURRENT OF ___VOLTS”, shall appear.
Surveyors shall ensure portable fire extinguishers are marked in accordance with the above instructions during SLE surveys. If portable extinguishers are not marked in accordance with the above instructions, the MSI has indicated their use shall be prohibited.
Not withstanding the above, the Administration has advised that, if the attached labels do not include some characteristics of secondary importance (e.g. solidification temperature, fire-extinguishing ability, etc.), this should not constitute a cause for their replacement if the remainder of the labeling information is considered satisfactory by the attending Surveyor.
The portable fire extinguishers should be inspected annually, by an approved service station.
The Surveyor shall verify that all portable fire extinguishers have been hydraulically tested as listed below:
Dry powder fire extinguishers:
All every 10 years starting from the date of their manufacture or the previous hydro test.
Portable CO2 fire extinguishers:
All every 10 years starting from the date of their manufacture or the previous hydro test.
Water and foam fire extinguishers:
All every 10 years starting from the date of their manufacture or the previous hydro test.
The portable fire extinguishers should be hydro tested at a pressure that exceeds the maximum working pressure as set by the manufacturer and inscribed on the extinguisher.
The pressure and date of the hydraulic testing must be permanently inscribed on the body of the fire extinguisher.
The Administration has advised that, until further notice, fire extinguisher service stations, which have been approved by Recognised Organisation (RO) in accordance with the external specialist approval program and IACS UR Z17 or the local Flag Administration (signatory to SOLAS 74) are acceptable.
The Administration requires, in addition to the last annual inspection date of fire extinguishers, that the name of the approved external specialist firm carrying out the inspection be recorded on the remarks section of the safety equipment check sheet, so that it can be made available on request. Qualified stations whose testing equipment has been inspected and certified by the Administration shall only carry out hydraulic testing of the extinguishers.
Extension for Annual Inspection and Hydraulic-testing of CO2 bottles/Portable Fire Extinguishers
If the equipment cannot be serviced within the 12-month period, an extension may be granted of up to 2 months from the date of expiry of the equipment inspection certificate, only in the following cases:
Either the ship has to depart urgently or there is not an authorized service station in the immediate area, or;
The period of time until the due date of the Safety Equipment certificate is short and the vessel's master intends to proceed with renewal of the ship's SLE certificate and the equipment annual inspection.
The equipment is to be visually verified in good condition. A declaration by the vessel's master stating that no significant fire has occurred necessitating the use of fixed or portable fire extinguishing equipment since the last inspection and that the equipment was externally examined and found in good working condition and ready for immediate use, can be considered as sufficient evidence, in situations where the Surveyor's attendance is difficult or impractical.
Additionally, the aforementioned extension may only be granted if a relevant comment exists on the certificate(s) of inspection, of the service station that made the last inspection, stating that the certificate may be extended for 2 months from its expiry date.
The contact office can grant the above extension without prior approval by the Administration. However, the Administration is to be immediately notified via the contact office, and ship’s Master be advised accordingly in writing.
Extension for the hydraulic-testing of CO2 bottles and portable fire extinguishers may be granted by the Merchant Ship Inspectorate (MSI) or by Recognised Organisation (RO) Surveyor when the ship is in a port where there are not facilities for carrying out hydrostatic testing or when there is not enough time to carry out the testing due to the ship’s sailing schedule. The extension may be recommended, provided that an MSI Surveyor or the Recognised Organisation (RO) Surveyor verifies that the CO2 bottles and/or portable fire extinguishers are in satisfactory condition.
Moreover, the extension should not be greater than 12 months, and if in that time, the vessel is due for a special survey the hydraulic-testing should be carried out during that survey. In cases where the extension is granted until the due special survey, the Surveyor shall make a note in the report regarding the necessity to carry out the hydraulic-testing of the extinguishers so that an entry may be made on the vessel’s status reminding the Surveyor of the requirement. If the vessel is not due for a special survey within the next 12 months, then the SLE Certificate should be endorsed with a provision stating the certificate ceases to be valid until (a maximum of 12 months may be noted) unless the requirement of hydraulic-testing of the extinguishers and/or fixed fire extinguishing system cylinders have been satisfied.
Exemptions for a Fixed Gas Fire-extinguishing System in Cargo Spaces
(SOLAS Regulation II-2/53.1.3)
Authorization from the Greek Administration is required prior to issuance of the initial exemption certificate. The expiration date of the exemption certificate is to coincide with the expiration date of the cargo ship safety certificate (SLE). In cases where the authorization from the Greek Administration is not available at the time of survey, an initial exemption certificate is not to be issued.
Breathing Apparatus and Spare Charges for Breathing Apparatus Smoke Helmet or Smoke Mask
Every smoke helmet required by this regulation, shall be provided with a flexible hose supplying air from the open deck and an air pump or blower suitable for discharging air through the flexible hose. The flexible hose shall be of a type that allows the free flow of air and it shall have a sufficient length so that the air pump or blower located at the open deck can discharge clean air to the person using the mask, to any part of the holds, engine room or accommodation spaces.
In the case that one or more lengths of flexible hoses are required to be connected together to cover the distance mentioned in the following paragraph, there shall be suitable fittings for this purpose kept in good condition. Verify that the suction of the air pump or blower is protected so that the supply of air cannot be impaired.
When the total length of the flexible hose exceeds 36m, the smoke helmet or mask is to be replaced by a self-contained breathing apparatus.
Self-Contained Breathing Apparatus
The following interpretations apply with regard to breathing apparatus. For further details on new construction vessels, refer to the Presidential decree number PD 379/96. (Copy is available from the contact office on request.)
Every breathing apparatus required by this regulation shall be of the open circuit pressurized air type.
The storage capacity of the cylinder(s) for the pressurized air attached to the apparatus and carried by the user of the apparatus should be at least 1200 liters (42 ft3) of free air.
The breathing apparatus bottles should be hydro tested every 5 years at a pressure that exceeds the maximum working pressure as set by the manufacturer. This also applies to the air support system bottles of totally enclosed lifeboats.
The apparatus shall be provided with means to automatically regulate the air supply to fulfill the breathing needs of the user. A by-pass of the automatic regulation valve should also be provided.
A pressure gauge shall be fitted in the high-pressure air supply system of the apparatus so that the user will be able to read clearly the air pressure inside the supply cylinder(s).
An audible alarm signal shall warn the user whenever 80% of the capacity of the apparatus has been consumed.
The manufacturer’s name and year of construction are to be marked on every breathing apparatus. An operating guide should accompany every apparatus with instructions for use written either in Greek or English language, which should also be clearly and conspicuously marked.
The Greek Administration has advised that for every self contained breathing apparatus there shall be spare cylinders fully charged with a total spare capacity of at least 2400 liters of free air.
Additionally:
The 2400 liters of spare charges shall be stored in more than one spare unit. For example, one bottle of 2400 liters capacity is not acceptable, but two bottles of 1200 liters with total capacity of 2400 liters is acceptable.
In case a ship has five or more such apparatus, the total spare capacity of free air shall be at least 9600 liters (336 ft3).
In case a ship is equipped with means to recharge the cylinders with clean air, under maximum pressure the spare storage capacity of the fully charged cylinder(s) of each apparatus shall be at least 1200 liters (42 ft3) of free air, and the total spare storage capacity of free air need not exceed 4000 liters (169 ft3).
Verify that the following equipment is provided with every breathing apparatus:
A fireproof lifeline having a length of at least 3 m (10 ft) longer than the distance from the open deck (clear of any hatch or doorway) to any part of the accommodation, service, cargo or machinery spaces. The lifeline shall be constructed of wire rope made of steel having a tensile strength of at least 500 kg (1120 lbs), and it shall be wrapped up with hemp or other material so that it is securely handled when wet.
An adjustable safety belt or strapping to enable the user to attach the lifeline securely to it by means of a snap-hook.
Means are to be provided for the protection of the eyes and face of the user from smoke.
Plates of suitable fireproof material shall have a clearly readable sign code to be used by the user and an observer, one of which shall be attached to the safety belt or the strapping and the other shall be tied to the free endof the lifeline.
For every apparatus (except for the smoke helmet type) a light weight safety helmet with an internal protective lining with an adjustable strap for securing it under the jaw.
Fire-extinguishing Arrangements for Paint and Flammable Liquid Lockers
(Regulation II-2/18.7 of the 1989 Amendments to SOLAS 1974)
The Hellenic Administration has advised that the following are its requirements for compliance with subject regulation:
Fixed fire extinguishing system operable from outside of the protected space.
Independent gas or powder unit automatically energized in the event of fire within the protected space.
Sprinkler system connected as an extension of either the existing sprinkler system or the vessel's fire main.
As to the calculation of the amount of fire-fighting medium required, the pertinent part of IACS Unified Interpretation SC80 is to be followed and is listed below for ready reference:
CO2 System, designed for 40% of the gross volume of the space.
Dry Powder System, designed for at least 0.5 kg powder/m3.
Water Spraying System, designed for 5 ltrs/m2/min.
The Greek Administration does not accept portable fire extinguishers for paint lockers with a deck area of less than 4 m2, as opposed to that stated in Section 4.7.2/5.1.2 of the S.V.R. 2000.
Fire Plans
The plans are to be in English or French and in the working language of the ISM, if other than English or French.
The application of IMO Resolution A.654(16) is not mandatory for Greek flag ships. However the Administration has advised that it accepts symbols on the fire plans in accordance with this resolution.
Portable Combustible Gas Detectors
(SOLAS Reg. II-2/62.17)
| TYPE OF VESSEL | EXPLOSION METER | O2 METER–DANGEROUS GASES |
|---|---|---|
OIL TANKERS up to70,000d.w.t(inclusive) | One(1)Explosion Meter |
|
OIL BARGES up to 200 d.w.t (inclusive) | 1 Explosion Meter; or 10 Disposable Hydrocarbon Measuring Tubes with relevant parts of the system |
|
CHEMICAL CARRIERS up to 70,000 d.w.t (inclusive) |
Additionally, when transporting cargoes with dangerous (toxic or flammable) vapors:
| |
GAS CARRIERS up to 70,000 d.w.t (inclusive) Additionally and more specifically for: | 1 electronic O2 meter, or 10 disposable O2 measuring tubes with relevant parts of the system. | |
| a. Those transporting liquefied gasesand hydrocarbons in general. | 2 explosion Meters (In addition to the permanent gas measuring equipment provided) | |
| b. For the rest of the cargo types |
| |
COMBINATION CARRIERS (OIL-ORE-CHEMICAL-GAS) up to 70,000 d.w.t (inclusive) | With instruments required above forthe category of cargoes beingtransported. | With instruments required above for the categoryof cargoes being transported. |
OIL TANKERS up to 70,000 dwt (inclusive) FITTED WITH INERT GAS SYSTEM | 1 explosion meter operating with both inert gases and atmospheric air, or separate explosion meter operating only with inert gases in addition to the explosion meter operating with atmospheric air |
|
| OIL TANKERS & gas, chemical, combination carriers above 70,000 d.w.t | Double the number of instruments required above as the case may be | Double the number of instruments required above as the case may be |
OIL TANKERS TRANSPORTING ACIDIC CRUDE OIL | The number of instruments required above as the case may be | The number of instruments required above as the case may be, and in addition: 10 disposable measuring tubes, appropriate for the measurement of hydrogen sulfide together with the relevant parts of the system. |
OIL TANKERS TRANSPORTING AROMATIC HYDROCARBONS | The number of instruments required above as the case may be. | The number of instruments required above as the case may be, and in addition: 10 disposable measuring tubes, appropriate for the measurement of aromatic hydrocarbons together with the relevant parts of the system. |
Emergency Escape Breathing Devices (EEBD’s)
(SOLAS 74/00 Regulations II-2/13.3.4 & 13.4.3)
The following tables contain the Flag requirements concerning the number and location of Emergency Escape Breathing Devices (EEBD’s). All Hellenic flag ships undertaking international voyages and that are subject to SOLAS Convention should comply with the following requirements not later than the date of the first survey after 01 July 2002.
Existing ships (keel laid before 01 July 2002)
| Passenger ships | Number | Location |
|---|---|---|
| Accommodation and service spaces |
| Distributed at conspicuous locations near escape exits |
| Category A machinery spaces and other machinery spaces normally occupied by crew |
The total number of EEBD’s should not be less than the number of persons normally employed in these spaces. | Distributed at conspicuous locations near escape exits from machinery spaces, control spaces and workshops (as applicable) |
| Spare Devices | None |
| Cargo ships | Number | Location |
|---|---|---|
| Accommodation and service spaces | Two (2) | Distributed at conspicuous locations near escape exits |
| Category A machinery spaces and other machinery spaces normally occupied by crew |
The total number of EEBD’s should not be less than the number of persons normally employed in these spaces. | Distributed at conspicuous locations near escape exits from machinery spaces, control spaces and workshops (as applicable) |
| Spare Devices | None |
New ships (keel laid on or after 01 July 2002)
| Passenger ships | Number | Location |
|---|---|---|
| Accommodation and service spaces |
| Distributed at conspicuous locations near escape exits |
| Category A machinery spaces and other machinery spaces normally occupied by crew |
The total number of EEBD’s should not be less than the number of persons normally employed in these spaces. Distributed at conspicuous locations near escape exits from machinery spaces, control spaces and workshops (as applicable) | Distributed at conspicuous locations near escape exits from machinery spaces, control spaces and workshops (as applicable) |
| Spare Devices | 2 for accommodation and service spaces | In safely accessible location (e.g. navigation bridge, fire stations,control stations) |
| Cargo ships | Number | Location |
|---|---|---|
| Accommodation and service spaces | Two(2) | Distributed at conspicuous locations near escape exits |
| Category A machinery spaces and other machinery spaces normally occupied by crew |
The total number of EEBD’s should not be less than the number of persons normally employed in these spaces. | Distributed at conspicuous locations near escape exits from machinery spaces, control spaces and workshops (as applicable) |
| Spare Devices | 1 for accommodation and service spaces | In safely accessible location (e.g. stations) |
Voyage Data Recorders (VDR)
Data to be submitted
The following documentation is to be submitted to Recognised Organisation (RO) technical department prior to the inspection of the installation:
Evidence of the type approval of the system, including the interfaces
A full list of the VDR components (central unit, capsule, interfaces, alarm unit, power source and any other component)
The wiring plan / block diagram of the installation
This is to include a description of all parts of the installation, including the external power source of the VDR components.
A layout (topology) plan of the installation of the various components
A full VDR interface list, which should include, but is not to be limited to, the following:
A description of the sensor (source of record data, description, manufacturer, type)
A description of the recorded signal
The format of the recorded message
The corresponding interface
The number and type of corresponding wiring
Detailed information as required by the Standard (§5.5) (Installation – operation – maintenance manuals and instructions for use by the Inspection Authority).
The ship’s operating data to be recorded by the VDR
Date and time:
As required by the Standard.
Ship’s position:
As required by the Standard, with the following clarifications:
With regards to the analysis of the recorded position, as well as the specification of the orientation (N-S and E-W), it is acceptable to record the data if they are available to the device’s output in an appropriate format to be recorded.
With regards to the assessment of the source’s condition, if it presents a particular reaction in the event that the supply of data to the VDR is cut off, it is acceptable to include this feature in the device’s configuration data.
Speed:
As required by the Standard, with the following clarifications:
The “designated equipment" for measuring the ship’s speed is assumed to be that which is required to be installed on ships, as foreseen in the regulations currently in force. If the “designated equipment” is not required to provide data in relation to speed “through the water”, it is acceptable to record the data in relation to speed “over the ground” (e.g., from a GPS receiver).
In cases where the speed measuring device already fitted is a speed log, which may not be compatible with the VDR, GPS as an alternative connection will be accepted.
Heading:
As required by the Standard.
Bridge audio:
As required by the Standard.
VHF communications:
As required by the Standard, but it must be clarified that the VHF device to be connected to the VDR will be that which is closest to the main conning position manned by the Officer on duty.
Radar:
As required by the Standard, but it must be clarified that, preferably, the radar device to be connected to the VDR will be that which operates on X-band.
Echo sounder:
As required by the Standard. It is clarified that it is acceptable to record the data of the current scale and status used, if they are available to the device’s output in an appropriate format to be recorded.
Main alarms:
As required by the Standard, with the following clarifications:
The status of the IMO mandatory alarms is to be recorded by the bridge audio, while any visual parameters will be recorded as data parameters, wherever practicable, taking into consideration the technical limitations or peculiarities of the manufacture. In all cases, the connection of any equipment to the VDR is not to impair the operation of the equipment, even in the event of malfunction of the VDR.
With regards to the informative Annex B of the Standard, its application is accepted in principle and, until such time that it is finalized, the following clarifications, additions and corrections are offered:
With regards to point 1, the recording of the “short circuit protection” alarm is not applicable.
With regards to point 9, it is applicable only in cases of centralized hydraulic systems.
With regards to point 13, any inner doors and closing means of the accesses to spaces below the main deck (doors, ramps, hatches) are included.
With regards to points 16 and 17, the following are required:
the recording of the alarms of both sprinkler and fixed fire detection systems,
the activation alarm of the sprinkler system, as well as the fire alarm of the fire detection system, are to be separate for each section, and
the recording of each of the fault alarms available in the corresponding alarm panel.
Rudder order and response:
As required by the Standard, with the following clarifications:
It is required to record the rudder control commands via all the systems (Follow-Up (Hand), Non-Follow-Up (NFU)), in combination or independently of each other, “Joystick” if it is used from all positions (helmsman’s position, watch positions in the center and the wings of the bridge etc), as well as the mode of operation.
The control commands and the rudder response, as well as the status and heading or track controller, if provided, are to be recorded, as available and technically possible, taking into account the technical limitations, the peculiarity of the manufacture, and the importance of the above control means for the safety of the ship. In all cases, it is stressed that connecting any ship’s equipment to the VDR is not to impair the operation of the equipment, even in the event of malfunction of the VDR.
Engine order and response: As required by the Standard, with the following clarifications:
In the event that only engine telegraph is provided, then the control commands and the corresponding feedback must be recorded.
In the event that, in addition to the engine telegraph, there are also systems for the direct control of the propulsion plant (main engine revolutions, pitch etc), then:
It is required to record the commands of all the direct control systems which are used and via all the systems (Follow-Up (Hand), Non-Follow-Up (NFU, Back-Up), in combination or independently of each other, “Joystick” etc. from all the positions (helmsman’s position, watch positions in the center and the wings of the bridge, etc), as well as the position of the selectors of the mode of operation and the command control position from the bridge or the engine-room, and
the independent recording of the engine telegraph is also recommended.
In addition, all the commands and the corresponding feedback that are available on the bridge and they concern other functions of the propulsion plant (emergency stop of main engines, emergency disengage, emergency reduction, emergency override etc), must be recorded.
It is acceptable to record the feedback either as audio signals (buzzer etc) from the bridge audio or as digital data (data parameters).
With regards to the thrusters, the indication “running” or “not running” must be recorded, as well as the corresponding pitch.
It is acceptable to record the pitch as it is presented on the corresponding indicators on the bridge.
In all cases, it is stressed that connecting any ship equipment to the VDR is not to impair the operation of the equipment, even in the event of malfunction of the VDR.
Status of hull door openings:
As required by the Standard, but it must be clarified that the status of the safety provisions must also be recorded as it is presented on the bridge.
Status of watertight doors and fire doors:
As required by the Standard.
Acceleration and hull stresses:
As required by the Standard.
Wind speed and direction:
As required by the Standard, but it must be clarified that the appropriate sensor is considered the one that provides output in a format suitable for recording.
Additional installation information
Electrical Power source:
All the VDR components (including any remote components, e.g. interfaces, alarm units etc) are to be powered by the ship’s emergency switchboard and in accordance with the certification of those components.
The position of the VDR alarm unit:
The VDR alarm unit is to be placed in the wheelhouse.
Inspection of the installation:
A technician authorized by the manufacturer is to install the VDR. The authorization attesting to that fact should be submitted.
The VDR must be installed according to the manufacturer’s instructions and the Standard, and in evidence of this the technician must submit a relevant attestation.
Prior to the inspection of the installation, the VDR must have operated and recorded for at least twelve consecutive hours with all the installed sensors activated, in order for a detailed (point-to-point) check thereof to be conducted.
The inspection of the installation requires the presence of bridge and engine Officers, appropriately trained employees of the manufacturer or technician and special equipment for data testing (playback equipment), which should be provided by the technician.
GPS
In accordance with SOLAS Regulation V/19.1.2.2, ships constructed before 1 July 2002 are to be fitted with a “receiver for a global navigation system or a terrestrial radio-navigation system” (GPS) by the first survey after 1 July 2002. The Administration has advised that GPS equipment not complying with IMO Resolution A.819(19) would be accepted, provided the equipment had been installed on the vessel before 23 November 1995. In such cases, suitable evidence of the installation date is to be made available for verification.
Automatic Identification System (AIS)
Surveyor should refer to circular IMO SN / CIRC. 227 / 06-01-2003 which is not compulsory but considered by the Greek Authorities to be of great assistance in ensuring the full and effective operation and performance of AIS.
AIS systems installed must be of an approved type according to the requirements of Directive 96/98/EC, as amended with Directive 2002/75/EC and bear the required mark (steering wheel).
AIS systems which were manufactured prior to 23-03-2003 must be of an approved type according to the requirements of IMO Resolution MSC.74(69). In such cases, the necessary supporting documents are to be submitted to the Greek MSI for acceptance.
The Greek MSI advised that IMO Resolution A.917(22) includes useful information regarding the use of the AIS on ships.
Tests of the AIS may be conducted with the assistance of:
other ships which have the corresponding equipment.
Portable AIS Test Equipment.
off-shore stations (AIS station of VTS Piraeus, and once installed in the other operating VTS of Corfu – Patra – Igoumenitsa).
Prior to the inspection of the AIS installation, an application must be submitted accompanied by:
Evidence of approval of the AIS device.
Authorization of the technician issued by the AIS manufacturer.
A certificate for the proper installation and operation in accordance with IEC 61993-2 and these instructions, issued by the technician, including a brief description of the installation data.
It should be noted that the basic controls of the equipment and its performance must be conducted in the presence of the attending Surveyor and a representative of the manufacturer / technician.
In the event that there are no off-shore stations or other ship stations in the range of the AIS for checking the performance of the AIS, a note is to be made in the inspection report and reasonable time will be granted for a recheck when the ship is within the range of other AIS stations.
The following must also be noted:
All the components of the AIS equipment and the sensors which provide the data to the AIS (GPS, Gyro, Rate of Turn Indicator), must be powered from the ship’s main and an alternative power source (e.g. the emergency power source).
This alternative power source:
must not be the reserve power source of the GMDSS equipment, until such time that this issue is finalized by the competent bodies of the IMO.
if it is the ship’s emergency power source or the transitional power source, it must be able to provide power to the AIS as well as the other equipment connected thereto.
The information provided by the AIS and its operational test must be available at the main bridge watch position.
If the ship has RADAR/ARPA - ECDIS/ECS which, either as they are or with an upgrade in their software, can present the information provided from the AIS, then this operation can be implemented with the appropriate connection.
The cables for the connection of the main unit of AIS with the AIS antennas must be those necessary to achieve the greatest range for the AIS.
Navigation equipment, books and charts
Ships which do come under the provisions of SOLAS (passenger & cargo ships) are to be provided the marine instruments and navigation aids according to the following table. At the end of the table there are the explanatory notes, the number of which is referred to in brackets in the table:
| NAVIGATION EQUIPMENT, BOOKS AND CHARTS | SHIPS SUBJECT TO THE PROVISIONS OF SOLAS |
|---|---|
| 1. Copy of the original maritime glossary of IMO | All ships of over 300 register tons |
| 2. Automatic Radar Plotting Aids (ARPA) and means for recording its indications | According to SOLAS Regulations |
| 3. Means to measure the available depth of water | According to SOLAS Regulations |
| 4. Gyro-compass | According to SOLAS Regulations |
| 5. The Convention on the International Regulations for Preventing Collisions at Sea, (COLREG) | 1 pc |
| 6. International Code of Signals | 1 pc |
| 7. Direction finder | According to SOLAS Regulations |
| 8. Binoculars | 2 pcs |
| 9. Log | According to SOLAS Regulations |
| 10. Approved instructions on matters of safety, loading & unloading and carrying loads | All tankers |
| 11. MERSAR manual | 1 pc |
| 12. Publication of sea traffic control systems | 1 pc (See Note12) |
| 13. Hellenic Flag | 2 pcs |
| 14. Helm angle indicator etc and propeller revolution counter (tachometer) | According to SOLAS Regulations |
| 15. Chart Index | 1 pc (See Note 15) |
| 16. Astronomical navigation supplies (astronomy journals, sextants, nautical tables, chronometer) | 1 pc (See Note 16) |
| 17. Clinometer (on the Bridge) | 1pc |
| 18. Fog gong | According to the International Regulations for Preventing Collisions at Sea |
| 19. IMO Code for ships of special service (chemical tankers, gas tankers) or carrying solid cargoes in bulk, corresponding to the category for each such ship | All ships of special service |
| 20. Code for carrying dangerous goods (IMDG-IMO CODE-EMS-MFAG) | All ships carrying such cargoes |
| 21. Fog Bell | According to the International Regulations for Preventing Collisions at Sea |
| 22. The safety guide of the ICS or OCIMF or IAPH, depending on the type of tanker | All ships carrying such cargoes |
| 23. Magnetic compass | According to SOLAS Regulations (See Note 23) |
| 24. Magnifier for compass | 1 pc (See Note 24) |
| 25. Pilots and Sailing Directions and List of Lights | As advised for voyage areas (See Note 25) |
| 26. Tide tables | 1 pc (See Note 26) |
| 27. Table of rescue signals | 1 pc |
| 28. Navigation lights panel (visible-audible) | 1 pc (See Note 28) |
| 29. Search light | (See Note 29) |
| 30. Radio direction finder (RDF) and radar on the radiotelephone distress frequency | According to SOLAS Regulations |
| 31. Radar | According to SOLAS Regulations |
| 32. Distance-time data of engine shutdown and reversing | All ships of over 500 tons |
| 33. Turning circle data | All ships obliged to do so (See Note 33) |
| 34. Daylight signal light | According to SOLAS Regulations (See Note 34) |
| 35. Charts | According to SOLAS Regulations |
Note 12: Ships which undertake domestic voyages, or within the Mediterranean, Red or Black Sea, rather than being issued with sea traffic control systems, they need only carry charts (up-to-date) with the sea traffic control zones for the areas which have such zones.
Note 15: The index must correspond to the version of charts which are used on the ship. The charts are to be stored in chart stores in the chart room.
Note 16: Astronomical navigation supplies are not required for the following vessels:
Passenger ships which undertake short international voyages, during which they do not exceed a distance of 24 nautical miles from nearest land, provided they carry a second radar (which can operate independently of the other) or a satellite navigator.
Cargo ships under 500 tons engaged in international voyages, provided that they are not obliged to engage a C class Captain or higher.
Note 23: Cargo ships of 150 to 500 tons engaged in international voyages, must be fitted with:
A bearing magnetic compass.
A steering magnetic compass, unless the indications of the bearing magnetic compass are easily readable (via the optical reflector) from the helm.
A spare magnetic compass which can be alternated with the bearing magnetic compass, unless there is a steering compass or gyro-compass (or repeater), the indications of which are easily readable from the helm.
There must be sufficient means of communication between the location of the bearing compass and the bridge, at the discretion of the Administration.
Ships which must have an emergency steering position are to be provided with:
Arrangements for providing course information, and
Sufficient means of communicating with the bridge
Note 24: This is required in order to facilitate reading the indications of the compass, in the event that the compass does not have an in-built magnifier.
Note 25:
The latest edition of Pilots & Sailing Directions:
of the American Hydrographic Office (H.O.) or the English Hydrographic Department (H.D.), which cover the entire globe, and
of the Hellenic Hydrographic Service (H.S.), which cover the entire Hellenic State.
The latest edition of Lists of Lights:
of the H.O. and H.D., which cover the entire globe, and
of the Hellenic Hydrographic Service (H.S.), which cover the entire Hellenic State.
Note 26: These are not required for ships which undertake voyages within the Mediterranean, Red or Black Sea.
Note 27:
A panel of navigation lights
With an optical and acoustic damage annunciation, must be carried by:
Passenger ships undertaking international and short international voyages,
Cargo ships of 500 register tons and over undertaking international voyages.
With only an optical damage annunciation, must be carried by cargo ships between 300-499.9 GT engaged in international voyages.
Cargo ships below 300 GT are not required to carry a panel of navigation lights.
Note 28: Tugboats obliged to do so must carry a searchlight which is in accordance with the provisions of Presidential Decree 380/1977 and with the provisions of current legislation.
Note 29: The following ships must obtain turning circle data:
Passenger ships:
over 500 register tons which were constructed after 25.05.1990, irrespective of the voyages they undertake, and
over 500 register tons which were constructed prior to 25.05.1990 and undertake international voyages.
Cargo ships of over 150 meters.
Ships of over 1000 register tons which carry chemical loads in bulk or liquid gas.
Note 30: Cargo ships, irrespective of their tonnage, which undertake international voyages must carry an ALDIS portable daylight signal light.
All the supplies, which are in printed form, and the charts, which are foreseen in the table, are to be clearly labeled with the ship’s name, port, and register number.
ECDIS
Greek Flag Circular No 4339.20/03/11 dated 16th Nov.2011 "Installation and Operation of ECDIS on board Greek Vessels" sets the framework for ECDIS operation on board Greek flagged ships.
See the attached file “ECDIS_GR_Circular”.
BNWAS
Greek Flag Circular No 4339.20/02/12, issued on 17th February 2012, “Bridge Navigational Watch Alarm System (BNWAS); installation and specifications”, contains guidance and clarifications on the specifications with regard to BNWAS.
ROs issuing statutory certificates to ships subject to these requirements shall examine the ships compliance to these requirements.
See the attached file “BNWAS_GR_Circular”.
Cargo Ship Safety Radio Certificate
Radio specialist - Survey of GMDSS installations
The Administration has advised that until further notice, it is accepting radio technicians approved under the Recognised Organisation (RO) quality procedures and IACS UR Z17. If the technician is not properly certified as outlined above, the Hellenic Government will not accept the report, nor will they consider the radio installation as having been properly serviced.
The Hellenic Government requires one (1) copy of the radio technicians report to be forwarded to the Flag Administration through MOC Piraeus. The technician's report must contain details of the equipment found on board (manufacturer, serial number, type, etc.). The radio station license becomes invalid and must be renewed if any equipment is replaced. A copy of the last EPIRB maintenance report is to be sent together with the radio technicians report and testing check sheet to MOC Piraeus for distribution to the flag Administration. Furthermore, a copy of the general arrangement drawing shall be submitted by Recognised Organisation (RO) to the Administration for ships that have not previously been registered in the Greek registry of ships.
Safety Radio initial survey
Prior to the issuance of the initial safety radio certificate, the MSI approval for the GMDSS installation must be obtained for vessels already equipped with GMDSS and changing flag to Greece, or for new GMDSS installations onboard Greek flag vessels (in accordance with chapter IV of the 1988 SOLAS amendments).
The following information is to be submitted to the Administration:
Vessel’s Certificate Of Registry
Application for initial GMDSS installation, including a list of all radio equipment installed or to be installed
Plan(s) of the antenna installation including location and type
Wiring diagram for the connection of radio equipment
General arrangement plan of the radio equipment (including accumulator storage space) that should specify the exact location of each apparatus installed.
Plans and specifications required by the applicable SOLAS regulations for new construction vessels are to be submitted by the Builder or the conversion shipyard. For existing vessels on which owners are requesting issuance of a safety radio certificate, it is the Owners responsibility to supply the necessary plans and specification to the Administration. The MSI approval (usually provisional radio station license), plans, and specifications approved by the administration shall be referred to by the Surveyor when carrying out the initial survey.
The survey shall ensure compliance with the applicable requirements of the Hellenic flag as specified under Section 4.1.2.6.1 and Chapter IV of the International Convention for the Safety of Life at Sea, 1988 amendments.
Items of non conformance or deviations of the installed equipment from the approved drawings or the radio station license, or unsatisfactory condition noted during the survey shall be brought to the attention of the Builder, Owner, their representatives, or other appropriate party for remedial action.
If the deficiencies are not rectified during the course of the survey, the Surveyor is to contact the flag Administration for guidance via the MOC Piraeus.
Periodical / Renewal Safety Radio Surveys
Radio Station License
During Safety Radio Periodical/Renewal surveys, the validity of the ship's radio station license, which is issued by the Administration, shall be confirmed. Lack of a valid radio station license shall be treated as a minor deficiency. Vessel’ s master is to be immediately advised to renew the Radio Station License.
In addition, the Surveyor is required to verify the particulars of the radio installation against the ship's radio station license.
The list of approved equipment on the radio station license should correspond to the actual equipment provided onboard.
A new radio station license shall be issued if one of the following has changed: Name of Vessel; Port and/or number of registry; call sign and/or MMSI; Tonnage; or any radio equipment. When discrepancies are found between the actual provisions onboard the vessel and the equipment listed on the radio license, the Surveyor shall consider this discrepancy to be an outstanding deficiency. When radio equipment is found replaced or needs to be replaced during the course of the survey, the replacement equipment should be of a type approved.
Otherwise, if all is satisfactory, a comment shall be included in the Surveyor's report stating that a valid radio station license was verified onboard and that the list of radio station items was verified to correspond with the radio equipment provided.
If the radio installation is in any way not in full compliance with the regulations, the existing full-term Safety Radio Certificate should be retrieved, and if the deficiency is not considered major (affecting the safety of the ship), a short term certificate may be issued valid “to the next port of call” or for a period not exceeding 1 month from date of survey, pending rectification of the noted deficiency.
The Administration has advised that, provided the operational capabilities of the radio installation are satisfied in association with the transmission of distress and safety communications, the malfunction of the installation in the public domain of communications does not constitute a reason for detaining or delaying the vessel, especially in areas where repair facilities or spares are not available.
Radio operator requirement
Radio operator requirements for GMDSS equipped vessels shall fulfill the following:
For Area A1
One (1) crew member holding a Radio Officer Certificate (R.O.C), or one (1) crew member holding a General Operator Certificate (G.O.C), or one (1) crew member holding GMDSS Radio-Electronic Officer Certificate (R.E.O.)
For areas other than A1
At least two (2) crew members should have G.O.C or R.E.O. qualifications.
In case an exclusive radio officer holding a GOC is employed, a second holder is not required.
SSAS
If survey of the installation of the Ship's Security Alert System (SSAS) is requested during an SLR Survey, and the Hellenic Republic administration has approved the Ship's Security Plan and issued the International Ship Security certificate, the following documents are to be submitted to the administration through MOC Piraeus:
An SSAS installation report, including all connected equipment, and a report of the testing of the alarm from both activation points. Form Greece-SSAS is to be completed and countersigned with the Radio Technician. If the Radio Technician completes his own form/checklist, this form must be countersigned with the Radio Technician after the Survey.
A letter from the company installing the SSAS stating that the SSAS was installed in accordance with the manufacturer's instructions.
A copy of the SSAS type approval certificate.
Radio Log for GMDSS Installations
The Administration has provided specific instructions for the GMDSS logbook carried on Greek vessels. In addition to SOLAS Chapter IV, Regulation 19, the Administration has adopted specific requirements concerning the radio communications log book on Greek flag vessels, per Ministerial Degree 121/1996/B19.
Application
All Greek vessels provided with a GMDSS radio installation, either as required by the current international conventions or voluntarily, should be provided with and maintain a radio communications log book.
GMDSS Log Book Structure
Cover
The logbook should have a binding that can withstand long-term use and front and back cover pages made of cardboard laminated with plastic or equivalent material of orange color.
Ship Particulars
As a minimum, the first pages of the log book should contain the following ship particulars:
Ship’s name
Port and Registry number
Call sign and M.M.S.I.
Gross tonnage
Type of ship
Sea areas of operation
Accounting authority ID code
Date log-keeping began and ended
Radio communication operators information (name, operator’s license category and number, date signed on, date signed off)
Record/Data Section
The subsequent pages, intended for logging information, should be numbered from 1 to 200 and each page should have five (5) columns containing the following:
Date and time U.T.C.
Call sign or M.M.S.I. number receiving station
Call sign or M.M.S.I. number transmitting station
Traffic particulars
Frequency
Endorsement page
The log book should be endorsed and signed on each page and should contain one (1) last blank page intended for endorsement by the M.S.I. or by Greek Port Authorities or by the local port Greek Consular authority before logging of information begins.
The endorsement page should contain the following text either in English or in Greek language:
“This book was signed and endorsed on each page, counted and found to contain ______ pages and will be used as a radio communications log book on vessel Port of registry, Registry No _____ Call Sign ______ M.M.S.I Place and date ________ Sign and Seal of authority ________________”
It is to the responsibility of the vessel’s master to present the radio logbook together with the bridge logbook to the local port Greek Consular Authorities for endorsement. In addition to the above, for vessels on international voyages vessel’s master should endorse the logbook every month.
When the logbook is not found endorsed by the Administration as indicated above, this should be considered as an outstanding deficiency. The Surveyor should advise the vessel’s Master about the flag requirements. When situations arise when the vessel is not in a port where Greek consular authorities are available to endorse the log book, and no other deficiencies are found then a short term safety radio certificate may be issued valid for 1 month or to the first port of call where Greek consular authorities are available, whichever comes first, pending endorsement of the radio log book by the flag Administration.
Logging Information
The logbook should be written in ink and the entries should be clear and legible.
The logbook should be kept near the installation and should contain information relative to:
Distress, urgent and safety communications that are received form the vessel’s radio installation concerning the vessel or other vessels in the area.
Messages received concerning the safety of navigation in general.
Malfunctions to equipment and/or sources of energy including details of the problem and actions taken to restore operation of the equipment and peripherals.
The periodic tests and maintenance of the radio communications equipment.
Ship’s position (at least once per day).
Actions During Survey Of The Radio Equipment
The radio technicians assigned to carry out periodical surveys should check the current radio logbook for compliance with the administration’s instructions and make an entry in the radio log book for the survey and condition of the station in either Greek or English language. The radio technicians should also make a relevant statement in the remarks section of the report.
Items of non compliance of the current logbook with the above requirements are to be immediately brought to the attention of the vessel’s master for rectification.
Change Of Name / Change Of Flag
When a vessel changes name, without change of flag, a new logbook with the current name should be opened. The logbook with the previous name should be closed and kept in the vessel’s records. Changing the name on the logbook by crossing out or by other means is not allowed by the Administration.
When a vessel changes flag from Greece to another state, the Greek logbook should be closed (per 5.a above) and delivered to the vessel’s owner for retention.
Manuals, Spares, Publications
The operational and maintenance manuals for the radio installation should be either in the English or Greek language. In addition and irrespective of the maintenance methods used, sufficient spare parts, special tools and instruments to allow any emergency repair to the installation should be provided onboard. The term “sufficient spare parts” is interpreted as the parts recommended by the manufacturer to be provided with the installation and parts, which are perishable or require periodic replacement (i.e., fuses, lights, etc.). The books and publications required by the Administration are given in the following table according with the vessel’s areas of operation:
Shore-Based Maintenance
A stamped copy of the approved shore-based maintenance agreement has to be onboard and available for inspection by the Surveyor. Lack of such an approved (stamped) agreement shall be considered an outstanding deficiency and a short term safety radio certificate may be issued valid for 1 month.
Portable Two-Way VHF Radiotelephone Apparatus & Radar Transponders
The Portable Two-Way VHF’s and Radar Transponders (SART) should be stored on each side of the navigation bridge, as close as possible to the exit of the bridge wings, and ready for immediate use.
For each of the Portable Two-Way VHF’s, one (1) emergency battery should also be kept on the bridge close to the VHF’s, sealed, and ready for immediate use.
If the crew also uses the Portable Two-Way VHF’s for every day communication, provision should be made for rechargeable batteries and adequate number of battery chargers.
After 01 February 1995, VHF apparatus installed before 31 January 1999 all two-way VHF apparatuses provided on Greek vessels shall comply with the operational standards of IMO Resolution A.762(18). Any two-way VHF apparatus installed after 31 January 1999 shall comply with the operational standards of IMO Resolution A.809(19) and be of a type approved.
Any Radar Transponder (SART) installed after 23 November 1996 shall comply with the operational standards of IMO Resolution A.802(19), and be of a type approved by the Administration.
In addition, the Radar Transponder (SART) should be provided with a pole (mast) or other equivalent arrangement so that when placed on the survival craft, the height of the antenna should be at least 1 meter above the waterline.
Arrangement of Emergency Source of Power for GMDSS Radio Installations
The following approved methods of compliance concern the use of accumulator batteries:
The accumulators are permanently connected to the charger required by regulation IV/13.6.1, and in case of damage of the main charger, the accumulators are connected to a second charger of equivalent output.
The accumulators are permanently connected to the charger required by regulation IV/13.6.1, and the charger is additionally provided with low voltage alarm indicator, which activates automatically in the case of damage to the charger. Furthermore, a portable charger of equivalent output is to be provided, which in the case of damage to the main charger, is used for the charging of the accumulators. Alternatively (instead of the portable charger), the existence of appropriate means for the direct connection of the radio equipment installation to auxiliary emergency source of power (e.g. transitional accumulator and/or emergency generator) is acceptable.
The emergency source of power shall be in fully charged condition and shall be of sufficient capacity in accordance with the requirements of regulation IV/13.2. If the fitted accumulators are of the “lead-acid” type, the battery box or the battery room floor should be specially protected in such a way as to avoid corrosion from leakage by the accumulators.
EPIRBs - ID Numbers and Inspection/Maintenance
The identification numbers assigned to 406.25 MHz satellite EPIRBs for Greek flag vessels consist of nine numbers. The first three numbers represent the country in which the vessel is registered. For Hellenic Republic, these numbers are 237 or 240. The next three numbers are assigned by the Hellenic authorities to identify each particular vessel. The last three numbers are zeroes. The nine-digit code (MMSI) is included in the vessel’s radio license and vessel’s Registry Certificate. The Surveyor shall verify the number of approval from the MSI on the EPIRB as well as the RCC code string given to the vessel from the MSI. The RCC code string should be encoded in the EPIRB memory and it is contained in the radio license under MMSI.
Regulation IV/15.9 of SOLAS 1974 as amended, requires Satellite EPIRBs to be tested regularly at intervals not exceeding 12 months for all operational aspects with particular emphasis on frequency stability, transmission power, and coding. The tests will be carried out on board the ships or ashore by a qualified workshop.
In connection with the above, note the following:
In special circumstances the 12 months period can be extended for 5 months after approval by the Administration.
Test results should be kept in a special check sheet. (Sample provided by the Administration is given in Attachment B). The Surveyor is to provide copy of the Attachment B to the radio technician as necessary. Attached to the check sheet should be the print out of the special control equipment (i.e., GMDSS test box or decoder).
Regular maintenance as required by the manufacturer, battery replacement, coding or change of coding, and the subsequent inspection of EPIRBs’ for proper operation should be performed ashore by authorized workshops of the manufacturer and approved by the local Flag Administration. The Hellenic administration has advised that it has adopted MSC/Circ.1039, "GUIDELINES FOR SHORE-BASED MAINTENANCE OF SATELLITE EPIRBs," and it is to be followed whenever Shore Bases maintenance is carried out (at intervals not exceeding 5 years).
Surveyors are to check in detail the latest test report for correct follow up of EPIRB maintenance. The maintenance records / reports must have attached the relevant manufacturer’s approval letters and local flag authorization letter.
Lack of proper EPIRB maintenance records is to be considered a major deficiency.
For EPIRBs installed after 23 November 1996, the Administration advises that EPIRBs should comply with IMO resolutions A.810(19) [EPIRB 406 MHz], or A.812(19) [INMARSAT-E EPIRB]. The main additional requirement is that the EPIRB should activate automatic only when it becomes submerged or in contact with water.
Installation, programming, maintenance, and decommissioning of EPIRBS
Refer to Circular 2333.2/9217/2025 in attached file “Circular_2333.2_9217_2025_EPIRBS on board GREEK SHIPS”
Secondary Means of Alerting on Cargo Ships
Among other methods, the existing on board satellite EPIRB may be used as a secondary means of distress alerting, provided that it is installed near the navigation bridge or at a distance provided that it is equipped with remote control capabilities.
Exemption from Radio Direction Finder (RDF) Requirement
The Greek Administration has advised that in accordance with SOLAS, Greek flag vessels are not required to be fitted with an RDF. Accordingly, no exemption certificates will be issued by the Administration. Certificates exempting ships from the requirement to install an RDF device, which have been issued prior to 1 July 2002, will no longer be valid upon expiration of the relevant statutory certificate.
Exemptions / Extensions from Requirements of GMDSS
All requests for exemptions shall be forwarded to the Administration through the contact office and will be considered by the administration on a case-by-case basis.
GMDSS
(Refer to Synoptic to Ministerial Decision 2333.2/3091/2025 in attached file “GMDSS ONBOARD GREEK SHIPS & CRAFT.pdf”)
For ships that fall within the scope of Chapter IV of SOLAS 74, of Directive 2009/45/EC and Directive 1997/70/EC as in force, in addition to the requirements of the conventions/directives, the requirements of PART B and PART C of Ministerial Decision apply.
For the remaining ships, PART A and PART C of Ministerial Decision apply.
In addition to the above, for small craft falling under the scope of the General Port Regulation No 23 being furnished with a Protocol of General Examination instead of a Ship Operation’s Permit, the Ministerial Decision applies too.
The compliance of ships with the requirements of this new national regulation shall be verified during the first regular inspection after the publication of this decision.
Ships installing GMDSS radio-communication equipment for the first time shall immediately comply with the provisions set out in this Ministerial Decision.
Certificates of technical companies providing technical support to merchant ships flying the Greek flag for the maintenance and repair of GMDSS radio-communication equipment shall remain valid until their expiry, or until the date of the necessary intermediate, or renewal inspection whenever due.
For sea areas A3, an additional VHF/DSC is required, plus either an MF/HF DSC, or a recognized Satellite Ship Earth Station. An MF/HF DSC installation may cover the requirements for both primary (MF/DSC) AND duplicate (MF/HF DSC) equipment.
GMDSS installation drawings
(Circular 2333.2/66419/2023 in attached file “Circular 2333.2-66419-2023 GMDSS installation drawings”)
The GMDSS installation drawings are to be checked by Recognised Organisation (RO) with regards to their completeness, correctness and the installation’s illustration accuracy.
For each GMDSS installation, the following should be prepared:
Installation of antennas diagram
Electrical connections of GMDSS equipment diagram
Diagram of the spaces where GMDSS equipment and batteries are installed, including the specific position of each device.
For the batteries that are used as the installation’s back-up energy arrangements, calculation of their capacity.
More specifically, the vessels subject to the requirements of SOLAS, Dir. 2009/45/EU, HSC Code, DSC Code and SPS Code should be provided with drawings approved by Recognised Organisation (RO). The rest of the vessels that are not subject to any of the above requirements, should be provided with drawings reviewed by Recognised Organisation (RO) who issues the relevant certificates.
Passenger Ship Safety Certificate
Damage Control Drills for Passenger Ships
(FSA Circular No: 2341.5-1/7378/2020)
Damage control drills as per new requirements i.a.w. SOLAS regulation 11-1/19-1 having entered into force on 1/1/2020 shall apply to all passenger vessels falling under the scope of SOLAS Ch.I as well as to passenger ships engaged in Class A voyages falling under the European Directive 2009/45 as in force.
The new regulation mandates at least one damage control drill to take place every three months with the participation of the crew assigned with duties related to the damage control as mentioned in the Muster List.
In addition, for ships equipped with damage stability calculator, this very equipment is to be utilized during the exercise under simulated conditions of damage, or, alternatively, a relevant safe & appropriate communication link ashore shall be established (with e.g. managing company’s competent naval architect / marine engineer, RO’s ERS, etc.), if available. In this context, at least one flooding control drill per year shall be conducted with the participation of the managing company by including shore based support services if available (i.a.w. regulation II-1/8-1.3).
Additional requirements for each drill encompass the operation of watertight doors by all available means, the operational testing of bilge valves / bilge pumps, the familiarization / presentation of the flooding detection / leakage alarm and operation of potentially existing cross-flooding arrangements / cross connection valves.
The Muster Lists on board all Greek passenger ships subjected to the new requirements shall be amended / updated as necessary in order for the corresponding crew members’ damage control associated duties which are assumed during damage control emergencies to be addressed therein.
For further information, refer to attached file “7378_ SOLAS CH II-1 REG. 19-1 DAMAGE CONTROL DRILLS_signed.zip”.
Others
Document of Compliance delivered to ships carrying dangerous goods
(SOLAS 1974, Regulation II-2/19) - Circular N. 1425/2.03.96
Ships carrying dangerous goods constructed on/after 1 September 1984 shall comply with provisions of Regulation II-2/19 as defined in Regulation II-2/1[2.4]. They shall hold a document of compliance as provided for in paragraph 4 of Regulation II-2/19.
The Society may issue to these ships such a document of compliance, after survey.
The document of compliance shall be in line with the provisions of the pertinent MSC Circular.
The validity of the document shall not exceed 5 years and shall not, in any circumstances, exceed the validity of the Safety Construction Certificate.
IGC Code
The Administration has issued the following special instructions regarding the ventilation arrangements of paragraphs 16.3.4 and 16.3.1.2 of the Code:
The master gas fuel valve (required by paragraph 16.3.7 of the Code) should close automatically if the “required air flow” is not established or maintained in the inner wall of the gas fuel piping. The requirement for continuous monitoring of the “required air flow” is not sufficiently ensured by only the use of a switch, which is connected to the ventilation fan motors and activated by their shutdown, but the shutdown of the gas fuel supply is to be ensured automatically in any case that a reduction in the “required air flow” is encountered.
Alternative Fuel Vehicles (AFV)
(Administration’s Letter: 2322.3/79893/2023 dated 14/11/2023)
The use of alternative fuel vehicles (AFVs) poses safety risks to their carriers. AFVs include among other types:
Hybrid and purely electric cars equipped with batteries.
Cars with liquified and compressed gaseous fuels.
In the absence of harmonized European, or national normative references, instructions of the administration are presented regarding the passenger and cargo ro-ro ships departing from Greek ports and are carrying AFVs, aiming at preventing and minimizing fire risk and release of toxic fumes in garage areas.
The measures recommended are, inter alia, focusing on the loading of AFVs onboard, prohibition of loading of AFVs, on ro-ro ships, the supervision of car securing areas / garages of ships carrying AFVs, the familiarization of crew with potential hazards and the provision of appropriate fire-fighting equipment.
Refer to attached file “Recommendation on AFVs onboard Ro-Ro Ships.zip”
MARPOL 73/78
Annex I. IOPP Certificate
Oil Filtering Equipment 15 ppm and Bilge Alarm 15 ppm - Approval
(MARPOL, Regulation I/16(4) and Resolution MEPC 60(33) - Prot. 3232 B MARPOL/38/95)
Ships equipped with filtering equipment or bilge alarms 15 ppm approved on the basis of Resolution A.393(X) until 27 March 95 (date of coming into force of Resolution MEPC 60(33)) are allowed to continue to use the same provided they continue to operate satisfactorily.
This means that the equipment already installed will be accepted until it is detected (during mandatory and unscheduled inspections) that its performance standards are not in line with the maker's specifications. In such a case, the equipment must be replaced with a new equipment approved in compliance with Resolution MEPC 60(33).
Oil Filtering Equipment - Exemption
(MARPOL, Regulation I/16(3))
Regulation 16(3)(a) of Annex I to MARPOL provides for some possible cases when ships can be exempted from the installation of oily-water separating equipment provided certain conditions are met.
One of these conditions is the retention on board of all oily-bilge water for subsequent discharge to reception facilities.
Decision No. 1737/F 183534/86 of 16 July 1986 defines the technical specifications for the construction of holding tanks for engine room oily water residues required for their retention on board, as follows:
Construction characteristics
Material:
Steel or an alloy of equivalent strength.
Form:
Cylindrical or rectangular (except tanks constituting part of the ship's construction).
Factor of safety
> 4:1.
Equipment:
openings for the filling, vent pipes, indicator for measuring of tank content level, size of openings.
Dimensions:
Tanks required to have horizontal side dimensions greater than 76 cm and to be equipped with transverse cross bracing placed at distances of less than 76 cm, of the same material and thickness as the tank.
Installation:
In engine room (waivement possible for existing ships below 400 grt).
Capacity:
| Main Engine Power (kW) | Capacity (m3) |
|---|---|
| Up to 1000 | 1.5 |
| From 1000 to 20000 | 1.5 + (P - 1000)/1500 |
| Above 20000 | 14.2 + 0.2 (P - 20000)/1500 |
Test:
Before installation on board at 1.5 times the maximum working pressure. After installation on board, detect eventual leakages.
Documents:
Drawings or sketches of the installation and certificate of manufacture relating to the tank's strength shall be submitted to the Administration.
However, as regards structural point of view, ships on which a sludge tank has already been installed before publication of the above decision, should comply with these requirements as far as reasonable and practicable.
Separator capacity
The minimum output capacity of oily/water separating-filtering system installed on or after 30 June 1997 is given in the following table:
| Gross tonnage | Minimum capacity (m3/h) |
|---|---|
| 100-400 | 0,5 |
| 400-1000 | 1,0 |
| 1000-2000 | 1,5 |
| 2000-4000 | 2,5 |
| 4000-6000 | 3,5 |
| up to 6000 | 5 |
For oily / water separating-filtering equipment installed before 30 June 1997 not complying with the minimum requirements of the above table, at the request of the owner, the Administration may relax the requirements on a case-by case basis, provided the equipment is verified to be in good working condition by the attending Surveyor.
Not withstanding the above, for vessels built on or after 01 January 1999, which have not been constructed in accordance with the Hellenic flag requirements (e.g. changing flag to Greece) and for which the retroactive replacement of the installed 15 ppm oily / water separating-filtering equipment creates important technical difficulties, the administration at its discretion may accept lower separator capacity than that indicated in the above table provided:
Recognised Organisation (RO) proposes same to the administration providing technical justification, and
The installed equipment is in compliance with the requirements of EC Directive 96/98/EC as amended by EC Directive 98/85/EC.
All requests to be directed to the administration via the contact office.
If ship’s fuel oil tanks are also used for ballast then the minimum capacity of the system is calculated by the following formula:
Q = V / (10 H)
where:
Q = Capacity of the system in cubic meters per hour (M3/H)
V = Total volume of fuel oil tanks, used for ballast, in cubic meters (M3)
H = Number of days in a voyage
On High Speed Craft, under the regulations of HSC Code, the minimum output capacity of the filtering system should be half of that mentioned above.
Sludge Tanks and Incinerators
Each new or existing ship must be provided with either main sludge tank for the collection of all sludge or with three independent tanks for the separate collection of:
Separated sludge (i.e. sludge from purification of fuel and lubricating oil),
Drain and leakage oil (i.e. drainage and leakage in machinery spaces) and,
Exhausted oils (i.e. exhausted lubricating oil, hydraulic oil or other hydrocarbon-based liquid which are not suitable for use in machinery due to deterioration and / or contamination).
In case where the vessel is provided with only one sludge tank, its capacity must be equal to the aggregate capacity of tanks under paragraph 1 above.
Capacity of Sludge / Garbage Incinerators
The incinerating capacity of incinerators onboard Greek Flag vessels is to be sufficient for handling the total daily production of sludge and garbage onboard with adequate idle time for maintenance. In vessels with unattended machinery spaces, the incineration of garbage (that requires manual feeding of the garbage material to the incinerator) and the incinerator’s maintenance are to be carried out during the working hours of engineering personnel (40 hours per week). Furthermore, incinerators intended for operation without attendance (beyond the working hours of engineering personnel) are to be fitted with the required automatic controls and alarms.
Vessels on national voyages
Vessels on national voyages that are issued a Certificate for the Prevention of Pollution by Oil, that have total engine power less or equal to 1500 BHP, that use GAS OIL as fuel, and that are fitted with only one centrifugal oil separator are exempted from the requirement of the installation of an independent sludge tank. The collection and disposal of the separation residues in this case should be done by the pump for the collection and disposal of oily mixtures.
Pumps and Piping Arrangement for the Disposal of Oil Residue and Bilge Water from Machinery Space
The overboard discharge piping from the oily/water separating or filtering system must be totally independent from any other piping system (e.g. ballast, bilge, etc.) and shall be fitted with a by-pass arrangement for re-circulating to either the holding tank or engine room bilges.
The pump that serves the tank for the collection of separated sludge or the sludge tank should not be a gasoline engine driven one, should be suitable for liquids of high viscosity, and should be equipped with safety features in case of loss of suction of the pump.
The minimum capacity of the pump shall be 2 m3/h. In no case shall the suction height of the pump be higher than 3 meters. The pump should discharge either to the standard discharge connection or to the vessel’s incinerator system.
The overboard discharge valve of any direct bilge overboard discharge line, unless passing through the 15 ppm oily-water separating and filtering system, should be kept shut and lead-sealed. In cases where this is not practicable, the bilge suction valves of the pumps that discharge overboard the vessel should be lead-sealed shut.
The overboard discharge from the oily-water separating and filtering system shall be provided with a valve at the vessel’s shell.
SOPEP
The SOPEP can be approved either by the Administration or by the Society.
It will be accepted that the documentation bound to SOPEP drills be included in the SMS in accordance with the ISM Code, subject to all information required by Circular 3232B MARPOL/64/95/ 16-1-95, paragraphs 4 and 5, being made available therein.
Whenever the ship working language is English, in accordance with the ISM Code, the SOPEP shall be in English. SOPEP translation in Greek language may be made available, if feasible.
The above requirements shall be checked for compliance during review of SOPEPs and/or, as far as possible, on board ships during IOPP surveys and/or ISM Code audits.
Interpretation and Application of MARPOL Annex I
Piping and valves used for pumping out, collection, processing and discharge of machinery bilges oil residues should be painted orange so that they are readily distinguished by the ship’ s operators-members of the crew as well as by the competent bodies carrying out scheduled and unscheduled inspections. Furthermore, the Flag Administration advised that they would have no objection for the application of the ISO standard 14726 for the coloring of the piping system of vessels under construction, provided that the coloring will be readily distinguished.
An indicative label with the following statement “Machinery Space oily mixtures suction and discharge pump” should be provided to every pump used for the pumping out of machinery space oily mixtures, their collection in the holding tank and their discharge to reception facilities by means of the standard connection. In case this pump is also used as a bilge pump or a general service pump, then all its discharge valves at the ship’s sides should be provided with labels stating that: “Discharges overboard, by the use of the valves shall be prohibited excluding emergency cases”. These valves should be “closed” at all times, and in case they are remotely controlled, the label should be suitably placed near remote control positions.
Any bilge line bypassing the 15 ppm oily-water filtering system and discharging directly overboard, should have the overboard discharge valve “closed” at all times and lead-sealed. In addition these discharge valves at the ship’s sides should be provided with notice label stating that: “DISCHARGES OVERBOARD, BY THE USE OF THIS VALVE ARE PROHIBITED, EXCEPT IN EMERGENCY CASES”.
In case the valves are remotely operated, the notice label should be suitably placed at or near the remote control positions.
In cases where due to operational reasons closing and lead sealing of the discharge valves is not practicable, the bilge suction valves of the pumps that discharge directly overboard should be lead-sealed shut and notice label provided.
The lead seal may be broken for maintenance of the valves, however the chief engineer is responsible upon completion of maintenance work to close the valves, replace the lead seal and make an entry in the engine log book or oil record book part I.
The responsibility of having the bilge discharge or suction valves closed, lead sealed and with the notice exhibited lays to the vessel’s chief engineer.
The Surveyor should verify that no alternative unauthorized modifications, such as spool pieces, blank flanges, locking arrangements that require the use of a key or arrangements which may impair the quick use of the emergency bilge pumping line to overboard as foreseen by MARPOL I, Regulation 11(a), are made to the vessel by the crew.
Extension of Certificates
The Administration has authorized Recognised Organisation (RO) to extend the validity of Harmonized MARPOL 88 protocol certificates for a period not exceeding 3 months from their expiry date, as foreseen by MARPOL 88 Annex I regulation 8(5). The extensions may be granted, in accordance with the provisions of subject regulations, provided that from relevant surveys and records kept, the Recognised Organisation (RO) determines that there are no outstandings affecting the safety of the vessel and the protection of the environment, and that the vessel is considered fit for the intended service for the duration of the extension period. The extension to the certificate may be in a form of telex or fax to the vessel’s master with copy the MSI and the Owners. A Recognised Organisation (RO) Surveyor shall endorse the extended certificates for the extensions at the first port of call where attendance is practicable.
Annex II. NLS Certificate
Reserved.
Annex IV. ISPP Certificate
Reserved.
Annex V
Special instructions regarding National Requirements and Interpretations are as follow
Procedures
Copies of Statements of Fact
A copy of the Statement of Fact issued shall be sent via MOC Piraeus to the Administration for its records.
National Requirements
Recognised Organisation (RO) shall ensure that the ship complies with the following national requirements and interpretations as applicable.
Garbage Management Plans
Garbage Management Plans should be provided, but are not required to be approved by MSI.
The plans may include topics from the existing instructions issued by the owners, such as instructions, definitions included in the safety management booklet from the ISM code.
For every category of garbage, the more suitable method for the disposal of garbage, depending on the equipment installed on board, should be evaluated.
Placards
The placards, required by Regulation 9, should be of at least 30 x 25 cm, made of durable material and be placed in a visible position in the galley, dining room, bridge and on the main deck of the ship.
In the cases of passenger ships, in addition, at least two placards made of water resistant material, should be placed in every passenger deck (one in every side of the ship’s open decks).
Annex VI. IAPP Certificate
Issuance of Certificates as per MARPOL Annex VI and NOx Technical Code
The Administration has authorized Recognised Organisation (RO) to conduct surveys on its behalf for the issue and maintenance of the International Air Pollution Prevention Certificate (IAPPC) in accordance with MARPOL Annex VI and the Engine International Air Pollution Prevention Certificate (EIAPPC) in accordance with the NOx Technical Code.
Data Collection System for fuel oil consumption of ships
Recognised Organisation (RO) is authorized to perform the following statutory services (not only on ships classed by Recognised Organisation (RO)):
verification of the SEEMP Part II and issuance of Confirmation of Compliance
verification of data reporting
issuance of Statement of Compliance
EEXI
ShaPoLi and EPL systems
(Administration letter No: 2323.2-6/89563/2022 dated 16.12.2022)
According to paragraph 2.1 of MEPC.335(76) “2021 Guidelines on the Shaft/Engine Power Limitation System to comply with the EEXI requirements and use of a power reserve”, as an acceptable method of compliance with the energy efficiency index of existing ships (EEXI), the installation of a shaft power limitation system (ShaPoLi) or main engine power limitation (EPL) may be considered. These systems, where technically feasible, can be controlled and regulated from the ship's wheelhouse (navigating bridge) without to be necessarily monitored by the engine room staff (according to MEPC.335(76) paragraph 2.1.3).
According to paragraph 1.3 and paragraph 1.4 of MEPC.335(76) “2021 Guidelines on the Shaft/Engine Power Limitation System to comply with the EEXI requirements and use of a power reserve”, the limitation of the offered shaft power (SHaPoLi) or power of the main engines (EPL), must be carried out with technical means, either by electronic/automated arrangement or through manual order/procedure by Master or Officer In Charge of Navigation Watch (OICNW) after exceedance of the power which is indicated by the activation of an alarm system on wheelhouse (navigating bridge).
SEEMP Part III
Recognised Organisation (RO) can proceed with the review and approval of the submitted SEEMP Part III and the issuance of the corresponding CoC in the context of the existing authorization agreement that makes generic reference to Marpol Annex VI by means of which EU ROs have been granted delegated power in full scope.
BWM Convention
Issuance of IBWMC
(Email dated 31/08/2017)
Following ratification by the Administration, ships are to be issued with International BWM certificate, for which Recognised Organisation (RO) is authorized. Specific IBWMC for Greek flag is bilingual (English/Greek) and available in Certificate Editor.
(For non Greek ships calling in Greece the BWMC applies only after 26th September 2017.)
IOPP de-harmonization
(Greek Administration Circular dated 08/03/2017).
The Administration implements IMO Res. A.1104(29), "Survey Guidelines under the Harmonized System of Survey and Certification (HSSC), 2015.", on ships flying the Greek Flag, under the reservation that the harmonization of the date of issuance of IOPP certificate after a renewal survey with the remaining statutory certificates as foreseen by the subject Resolution, is not required.
The above takes effect on the 8th March 2017.
No prior agreement from the Authorities is required but Recognised Organisation (RO) should be contacted on a case by case basis.
Ballast Water Treatment System (BWTS)
The Type Approval Certificate of BWTS issued on behalf of the Greek Flag must be bilingual (English/ Greek).
The Administration requires that the BWTS installed on board Greek Flag ships are to be type approved by them or by an RO on their behalf, regardless the installation date: IBWM certificates shall be D-2 ticked only if the installed BWTS is approved by Greek Flag or by an RO on their behalf.
BWM Record Book
(Refer to Greek FSA Circular No: 2263.1-14/5156/2025 dated 24/01/2025 in attached file “Circular 2263.1-1451562025_BWM Record Book.zip”)
As an interim way of meeting the requirements of the BWM Convention (i.e. amendments to the BWM Record Book format which enter into force on 1st February 2025), existing Greek ships should make use of the template attached to the FSA Circular until a new official BWM Record Book will be made available by the Greek Seafarers’ Pension Fund (NAT).
(Circular 2263.1-1414/24801/2025 in attached file “Circular_2263.1-1414_24801_2025_BWRB”)
Vessels subjected to the BWM Convention should have been furnished with the new BWMRB (available via the Greek Seafarers’ Pension Fund - NAT), by June 15, 2025, at the latest (see also Ballast Water Record Book).
Tonnage 69
Tonnage Certificate
(Memo dated 25/09/2007)
TLO must send to the Greek Administration one copy of the international tonnage certificate (1969), at the following address: HELLENIC REPUBLIC MINISTRY OF MERHANTILE MARINE MERCHANT SHIPS INSPECTION MEASUREMENT DEPARTMENT 1, Konstantinou Palaiologou 18535 Piraeus, Greece
The ITCs 69 issued outside Greece are stamped with normal Recognised Organisation (RO) Stamp.
The ITCs 69 issued by HPO are stamped with a local stamps from the Greek Ministry of Finance & taxes.
Eventually, the original tonnage certificate and one copy of it shall be sent to the client (the copy is required in order to be forwarded to the appropriate ship´s register by the client).
Miscellaneous Technical Requirements
Cargo Gear Surveys
Definition
The term lifting appliances includes:
All permanently installed devices such as cranes, derricks, cargo winches, masts, loaders, cargo and personnel (passenger / crew) elevators, and any other type of appliance, which is used for loading or unloading cargo or supplies, together with any associated loose gear.
Hoists and davits for hose handling gear, machinery space hoists, cranes / derricks for stores, including any permanent overhead structures (such as I-Beams) that are specially configured and/or arranged to accommodate fixed lifting appliances.
The term lifting appliances does not include:
Lifeboat, rescue boat and liferaft davits,
Embarkation ladder hoists for passengers and/or crew,
Mechanical pilot hoists,
Suez canal light hoists and Suez canal boat davits, and
Isolated lifting arrangements, such as portable hoists, chain blocks, pulleys, etc., which are mainly used for maintaining the ship’s machinery and which are considered as tools, as well as their points of attachment (pad eyes, trolley beams, I-beams, etc.)
Application
Pertinent to the requirements of Presidential Decree, No. 316/2001 published on 25 September 2001, the lifting appliances on Hellenic flag vessels should be surveyed and certified before being placed into service and at set time periods, to establish that they can operate without danger to the crew, or any person working onboard the vessel who may use or be near that appliance.
The certification of lifting appliances on behalf of the Hellenic Republic is mandatory and will normally be in addition to the conventional RO-issued Register of Cargo Gear, which is optional.
It is the responsibility of the owner to obtain and maintain the Greek certification. At the request of the owner, the Surveyor may carry out initial surveys required for the certification of lifting appliances, in accordance with P.D. 316/2001, as described below.
Register
The appliances complying with the requirements of Presidential Decree, No.316/2001, are certified as follows:
For cargo ships a Hellenic Cargo Gear Register book is endorsed.
For passenger ships a Certificate of Fitness of Cargo Gear and Lifts is issued.
Conventional Cargo Gear
Initial Survey
The requirements for obtaining and maintaining the Hellenic Certification are obviously the same as those required for issuance of a Recognised Organisation (RO) Register of Cargo Gear and displayed in the related survey procedure.
The actual Initial Survey for certification of lifting gear on board Greek flag vessels is to be of sufficient extent and scope to satisfy the Surveyor that the lifting gear complies with approved plans and applicable requirements, was found in satisfactory condition upon examination, and was proof load-tested as required for initial certification.
Four copies of each drawings and two copies of the supporting calculations should be submitted to Recognised Organisation (RO) for review. One approved copy of each should then be forwarded to the Hellenic authorities via MOC Piraeus.
For vessels having a valid Recognised Organisation (RO) Cargo Gear Register covering all lifting appliances required to be certified by the administration, the Surveyor can issue the Hellenic Cargo Gear Register book for cargo ships or Certificate of Fitness of Cargo Gear and Lifts for passenger ships provided that the necessary proof tests and examinations have been satisfactorily carried out by the Surveyor.
Upon satisfactory completion of the initial survey, the attending Surveyor may complete and endorse Hellenic Cargo Gear Register book of cargo ships or issue a Certificate of Fitness of Cargo Gear and Lifts of passenger ships (as the case may be) valid for 5 years.
The register or certificate should not be endorsed or issued until all fitted lifting appliances have been approved and satisfactorily examined / tested.
In cases where not all of the lifting appliances required to be certified by the Hellenic administration are covered by the Recognised Organisation (RO) Cargo Gear Register, and if requested by the owners, the Surveyor may commence the initial survey by carrying out all the necessary proof load tests and examinations of the lifting appliances not previously certified, pending submission, review and approval of relevant drawings.
Then:
Upon satisfactory completion of plan approval of the lifting appliances not previously certified, all of the lifting appliances can be certified with a Hellenic Cargo Gear Register book for cargo ships or a Certificate of Fitness of Cargo Gear and Lifts for passenger ships. The additional lifting appliances for which plan approval has been completed may be also inserted to the Recognised Organisation (RO) Cargo Gear Register and be issued with an Recognised Organisation (RO) cargo gear certificate valid for 5 years from the date proof load test.
In the event that structural drawings, force diagrams, etc., are not available for certain small sets of gear, which have to be certified in accordance with Hellenic requirements (e.g. provision cranes, machinery overhead gantry cranes, etc), the administration may authorize / accept subject gear on the basis of satisfactory service experience and proof load tests / examinations carried out by the Surveyor. All requests for waiving of plan approval in cases of unavailability of drawings should be directed to the administration through Recognised Organisation (RO) Piraeus technical office. When authorized by the administration the Surveyor may endorse the Hellenic Cargo Gear Register book for cargo ships or to issue a Certificate of Fitness of Cargo Gear and Lifts for passenger ships for all of the lifting appliances. As the requirements to obtain Hellenic and Recognised Organisation (RO) certification are essentially the same, it is important to keep in mind that Recognised Organisation (RO) requirements take precedence over the Hellenic relaxation (i.e. if the approval / certification is required to issue an Recognised Organisation (RO) Cargo Gear Register), then it should be performed.
Periodical Annual Surveys
An annual survey is required to be carried out within 3 months before of after each annual anniversary date of the crediting of the initial or previous retesting survey.
The administration requires that the vessel’s crew carries out every 3 months periodical inspections of the lifting appliances and conditions found are to be recorded in the vessel’s logbook of drills and inspections.
During periodical annual surveys, the Surveyor is to examine the logbook for proper entries of the periodical inspections by the crew. In case the logbook is not found properly completed, as required by the administration, it is not to be considered as an outstanding deficiency, however the Surveyor is to advise the master accordingly and note same in the survey report.
Refer to the related survey procedure for survey instructions
Renewal / Retesting Surveys
A Renewal / Retesting Survey is required carried out on the lifting appliances covered by the Hellenic register or certificate at 5-year intervals from the anniversary date of the initial or previous retesting survey.
The completion of the requirements of an annual periodical survey is required as part of the renewal survey.
In addition proof load testing for the certified conditions and thorough post examination of the lifting appliances and loose gear after dismantling are required. The administration accepts dynamometers for proof load testing of lifting appliances, provided the accuracy (calibration records) is to the satisfaction of the attending Surveyor.
The administration recommends that a sufficient number of the heavily stressed and/or not normally accessible for inspection parts of the lifting gear to be opened for examination by the Surveyor, at his discretion, to satisfy himself that the gear is considered to be in satisfactory condition.
Upon satisfactory completion of a Renewal/Retesting Survey, the attending Surveyor may issue a Certificate of Fitness of Cargo Gear and Lifts of Passenger Ships or endorse the Hellenic Cargo Gear Register book of cargo ships (as the case may be) valid for 5 years.
For cargo vessels having already been issued a Hellenic Cargo Gear Register book only endorsement of the register for retesting survey will be necessary, with next due date of 5 years from the date that the appliances were proof load tested and examined.
For consistency if the proof testing and examination of some of the lifting appliances has been carried out on an earlier date than others, the validity of the register or certificate must be dated from the earlier survey.
Loose Gear
The administration requires that the construction materials for hooks, chains, swivels, wire ropes, sheaves, blocks and other loose gear to be of adequate strength to fulfill with safety their intended service. Loose gear certificates furnished by the gear manufacturer or supplier when gear is initially installed or renewed are not accepted by the administration, unless certified by a recognized classification society. This requirement does not apply to wire ropes, were the administration accepts certificates of test by the manufacturer.
Elevators
Reserved
European Marine Equipment Directive 96/98/EC
Refer to Statutory surveys - General, Section 7 and Section 8.
Recognised Organisation (RO) is authorized as an EU Notified Body to verify compliance with EU requirements for the use of the CE mark.
EC Directives 96/98/EC as amended by Directives 98/85/EC, 2001/53/EC and 2002/75/EC require equipment installed on board ships to be marked in accordance with the EC Directives. Such equipment includes LSA, oilfiltering, oil water interface, ODMC, sewage treatment plants, fire protection, navigation, and radio equipment, etc.
The Ministry of Mercantile Marine has issued the following instructions for Greek flag vessels:
After 1 January 1999, and subject to the provisions of paragraphs 2 and 3 below, the equipment described in Appendix A.1 of the 96/98 EC Directive as amended by EC Directive 98/85/EC can be installed in a Greek merchant vessel only if the equipment has the symbol of Article 11 (i.e., steering wheel mark).
From 1 January 2002 equipment, described in Appendix A.1 of the 53/2001 EC Directive, replaces equipment described in Appendix A.1 of the 96/98 EC Directive.
From 1 January 2004, equipment described in Appendix A.1 of the PD 294/2003 (adopting Directive 2002/75/EC) replaces equipment described in Appendix A.1 of the PD 137/2002 (adopting Directive 2001/53/EC).
Equipment listed as "new" in Annex A.1 of EU Directive 2002/75/EC, which was manufactured before 23 March 2003, in accordance with type approval procedures already in force, as well as equipment listed in Annex A.1, Sections 4 and 5, bearing the mark and manufactured before 23 March 2003, may be placed onboard Hellenic Republic registered vessels, the certificates of which have been issued by, or on behalf of, a Member State in accordance with international conventions during the two years following 23 March 2003.
Application
The above requirements are applicable to equipment that is installed on:
Every new ship (keel laid on or after 17 February 1997) wether or not built in an E.U. country member.
Every existing ship (keel laid before 17 February 1997) in the following cases:
Equipment not previously required is initially installed, or
Existing equipment is replaced, unless international conventions provide otherwise, whether or not the vessel is located in an E.U. country member during the said installation.
The above requirements are not applicable to equipment already installed on existing vessels prior to the 17 February 1997.
Extraordinary Cases
This section applies to all ships (keel laid before on or after 17 February 1997).
When equipment needs to be replaced in a Non-E.U. country member port and under special circumstances due to time, delay or cost limitations, it is impossible or impracticable for replacement equipment complying with the above EC directives to be installed, the MSI may authorize the installation of other equivalent equipment.
MSI should be immediately informed, via the contact office, of the special circumstances and the type, particulars and approvals of the replacement equipment prior to authorizing its installation. For radio-communication equipment, the MSI requires that the equipment does not unnecessarily affects the frequency spectra requirements.
European Marine Equipment Directive 2014/90/EU (New MED)
(Administration letter No: 2311.1-14/73352/2019 dated 10/10/2019)
Implementation of the Directive 2014/90/EU has been transposed into Greek law through the Common Ministerial Decision (CMD) No: 2222.1-1.1/90149/2016 “Adaptation of the Greek legislation to the provisions of the Directive 2014/90/EU of 23 July 2014 of the European Parliament and of the Council on marine equipment and on repealing Directive 96/98/EC” Greek Government’s Gazette No: 3454B’/26.10.2016.
In accordance with article 4 of the aforementioned CMD, marine equipment installed onboard any Greek vessel on or after 18/09/2019 shall comply with the requirements on the design and operational characteristics foreseen by the applicable international legal instruments in force on the date of installation on board.
For existing ships being transferred to the Greek registry, especially in case where a vessel entering the Greek registry was previously operated under a non –EU Member State flag: the ship is subject to an occasional survey by Recognised Organisation (RO) aiming at verifying that the condition of her onboard installed equipment conforms with her safety certificates and that it either fulfils the requirements of the decision and bears the wheelmark, or is deemed being equivalent at the discretion of the Greek FSA.
For further information, refer to attached file “Greek Maritime FSA MED Circular Oct 2019.pdf”.
Hellenic National Certificates
Issuance of Certificates
The following certificates/documents in Greek language are implemented in Certificate Editor and may be issued locally in Greece: - Hellenic Load Line Certificate - Hellenic Passenger Certificate EUROSOLAS and its Record Form P - Certificate of Fitness of Cargo Gear and Lifts of Passenger Ships - Commercial Yacht Inspection Certificate - Protocol of General Inspection for Commercial/Pleasure Yacht - Attestation of Successful Completion of Additional Control Procedures - Hellenic Protocol Cargo Ships Tanker Certificate - Hellenic Dynamically Support Craft Certificate - Hellenic Oil Pollution Prevention Certificate and its Supplement Form A & Form B - Hellenic Sewage Pollution Certificate
Survey code/checklists and Items
The following survey and certificate codes will be implemented soon in Neptune/ASMS2:
| Survey code | Survey description |
|---|---|
| HPCT - Hellenic Protocol Cargo Ships Tankers Certificate | |
| HPCR | Hellenic Protocol Cargo Renewal Survey (+ GMPS*) |
| HPCA | Hellenic Protocol Cargo Annual Survey (+ GMPS*) |
| HPCS | Hellenic Protocol Cargo Tailshaft Survey (+ TCEC*) |
| HPCO | Hellenic Protocol Cargo Occasional Survey |
| HLLC - Hellenic Load Line Certificate | |
| HLLP | Hellenic LL Periodical Survey (+ LLPS*) |
| HLLA | Hellenic LL Annual Survey (+ LLPI*) |
| HLLO | Hellenic LL Occasional Survey |
| HOPP - Hellenic Oil Pollution Prevention Certificate | |
| HOPP | Hellenic Oil Pollution Periodical Survey (+ POPS*) |
| HOPA | Hellenic Oil Pollution Annual Survey (+ POMA*) |
| HOPI | Hellenic Oil Pollution Intermediate Survey (+ POIS*) |
| HOPO | Hellenic Oil Pollution Occasional Survey |
| HPSC - Hellenic Passenger Certificate | |
| HPSR | Hellenic Passenger Periodical Survey (+ GMPS*) |
| HPSO | Hellenic Passenger Occasional Survey |
| HPYC - Hellenic Pleasure Yacht Certificate | |
| HPYR | Hellenic Pleasure Yacht Renewal Survey |
| HPYI | Hellenic Pleasure Yacht Intermediate Survey (+ GMPS*) |
| HPYO | Hellenic Pleasure Yacht Occasional Survey |
| HCYC - Hellenic Charter Yacht Certificate | |
| HCYR | Hellenic Charter Yacht Periodical Survey (+ GMPS*) |
| HCYO | Hellenic Charter Yacht Occasional Survey |
| HSPP - Hellenic Sewage Pollution Prevention Certificate | |
| HSWR | Hellenic Sewage Pollution Renewal Survey |
| HSWA | Hellenic Sewage Pollution Annual Survey |
| HSWO | Hellenic Sewage Pollution Occasional Survey |
| HDSC - Hellenic Dynamically Supported Craft Construction and Equipment Certificate | |
| HDSR | Hellenic Dynamic Speed Craft Periodical Survey (+ GMPS*) |
| HDSO | Hellenic Dynamic Speed Craft Periodical Survey |
| * These additional survey codes are to be selected when creating a RFJN | |
The National certificates checklist are in attached file “Hellenic Checklists - Mar 2022.zip” and shall be attached to the corresponding survey reports.
The list is as shown below:
Passenger vessels
Accommodation and calculation of number of passengers
The regulation entitled “Accommodation and calculation of the number of passengers on passenger vessels” applies to all passenger vessels engaged on scheduled voyages and to Greek flagged vessels carrying more than 25 passengers, engaged on tourist voyages. Applicability and requirements are detailed in the document “GREECE PRESIDENTIEL DECREE 44-2011.pdf” in attached files.
The relevant survey checklist/report is available in the attached file National Hellenic Checklists (see Survey code/checklists and Items).
Transportation of domesticated animals
(Administration letter No: 2070.0/74344/2021 dated 11.10.2021)
Pursuant to GR Law No: 4830/2021 (article 18), published on September 18,2021, all Greek passenger ships engaged in regular trade are obliged to carry updated General Arrangement Plans depicting the dedicated pet-cabins where domesticated animals (pets) can be borne safely with their owners/companions while at sea.Managing companies shall endeavour to ensure incorporating in their ticketing system indications about: the pet’s ID and the corresponding record related to each transported pet’s health record book, in relation to the available caging facilities onboard; this obligation acquires mandatory character on and after 18 September 2022.
Domestic voyages (aged passenger ships)
(Administration letter No: 2341.5-1/67710/2022 dated 26.09.2022)
Aged passenger ships engaged solely on domestic voyages - falling under Classes C&D as per Regulation (EU) 2020/411 - have not to mandatorily comply with the national regime of annual system audits in the scope of an intermediate verification.
Stability requirements for passenger ferries (ro-ro)
(Refer to Presidential Decree 65-2024 in attached file “Publication of P.D. 65-2024.pdf”)
The existing ro-ro passenger ferries that operated regularly to/from a Member State prior to 5th December 2024, continue to comply with the specific stability requirements set out in Annex I, in force on 17 of November 2004 (date of entry into force of P.D. 52/2005 - A' 79), in accordance with the Article 3 of the P.D. 65/2024.
For each new passenger ferry (ro-ro), of which the keel has been laid or which is at a similar construction stage after 5th December 2024 and certified to carry not more than 1350 passengers, it is required (in accordance with the Article 6, par. 2 of the P.D. 65/2024) that within a period of one month from the date of its certificate issuance (referred to in Article 8 of the same P.D), Recognised Organisation (RO) to submit, to the competent Directorates of the Ship Inspections Branch of the Ministry of Shipping and Insular Policy, the choice of the possibility mentioned on the first paragraph of Par. 2 (Article 6, P.D. 65/2024). This notification shall include the information mentioned in Annex III of the mentioned P.D.
Compliance with the special stability requirements of the P.D. 65/2024 will be stated by the mention of an appropriate instruction/guidance in the Appendix of the valid Passenger Ship Safety Certificate of each ship, in accordance with the Compliance Text Table as appended in the attached file “Publication of P.D. 65-2024.pdf”.
Operation of air conditioning systems in passenger ships engaged in domestic voyages
(Refer to GREEK FSA Letter No: 2070.0/75314/2025 in attached file “GR FSA Letter No 2070.0-75314-2025 dated 20-10-2025”)
Ships' managers / operators are to take adequate precautionary measures for the proper functioning of the air conditioning systems installed onboard, especially during the summer months, as set out below:
To ensure that procedures are put in place - in line with article 11 of the PD No 44/2011 (A'110) Accommodation Requirements & Rules on Number of Passengers of PAX ships, as in force - so as for the maintenance of the air conditioning systems to be formally included in the planned maintenance system onboard and / or in the shipboard part of the respective SMS
The regular maintenance service actions are to be systematically undertaken in line with the maker's technical manuals, and relevant records are to be kept.
Regular operational tests are to be conducted at a frequency not exceeding thirty days, and records are to be kept.
Closed passenger spaces are to be monitored in respect of prevailing ambient temperatures & humidity readings, which are to be recorded and controlled.
Operators, masters, etc., must report air conditioning units' malfunctions and/or inoperativeness encountered to the Administration, port authority, and / or to the RO issuing the affected statutory certificates.
The instructions at hand are to be adequately incorporated in the SMS and their proper implementation is to be regularly checked by Recognised Organisation (RO) during Periodical/intermediate and Renewal SMC and DOC audits.
Ships not subjected to the provisions of Commission Regulation (EC) No 336/2002 (ISM Code) must comply with the above as well.
Ship Recycling
Regulation EU No. 1257/2013
From 9 February 2026, Recognised Organisation (RO) must issue the combined certificates as per Commission Implementing Decisions (EU) 2026/121 and (EU) 2026/116, on 19 January 2026, replacing the existing EU SRR certificates and any possible SoC issued against the IMO Hong Kong Convention.
Hong Kong International Convention for the Safe and Environmentally Sound Recycling of Ships
(Administration letter 2263.1-15/43160/2025 in attached file “Letter_2263_1_15_43160_2025_Hong Kong Convention”)
By this letter, Recognised Organisation (RO) is authorized to issue a Statement of Compliance on Inventory of Hazardous Materials or Ready for Recycling Statement of Compliance in accordance with the Hong Kong International Convention for the Safe and Environmentally Sound Recycling of Ships.
ISM Code
Authorisations & Instructions
The issuance of ISM certificates to Greek vessels can be undertaken by competent Administration's auditors, even after September 30th, 2018 (date wherefrom only authorized ROs can assume these tasks i.a.w. Law No 4504/2017 (Article 106 (1)).
| Ship Type | PS | PH | PR | BC | OT | CT | GC | CH | CS | MO |
Document of Compliance | ||||||||||
| Interim | x | x | x | x | x | x | x | x | x | x |
| Initial | x | x | x | x | x | x | x | x | x | x |
| Periodical | x | x | x | x | x | x | x | x | x | x |
| Additional | x | x | x | x | x | x | x | x | x | x |
| Renewal | x | x | x | x | x | x | x | x | x | x |
Safety Management Certificate | ||||||||||
| Interim | x | x | x | x | x | x | x | x | x | x |
| Initial | x | x | x | x | x | x | x | x | x | x |
| Intermediate | x | x | x | x | x | x | x | x | x | x |
| Additional | x | x | x | x | x | x | x | x | x | x |
| Renewal | x | x | x | x | x | x | x | x | x | x |
Note: | ||||||||||
| Requirements of the Administration | Action by |
|---|---|
| Recognised Organisation (RO) issues SMC and DOC | MOC Piraeus |
| Copy of definitive audit reports, DOCs and SMCs to SCS | MOC Piraeus |
| SMC and DOC valid for 5 months shall not mention "short-term" | Auditor |
| Specific provision related to Passenger & Ro-ro vessels shall be found in the SMM (manual) - see attached instructions under item 2 below | Auditor/ CSQM/ MOC |
| During change of flag DOCT and SMCT are required unless different instructions are received from flag - see instructions under item 2 below | Auditor/ CSQM/ MOC |
| On and after 15/04/2010, all SMMs shall incorporate the mandatory reporting of incidents and accidents at sea , as prescribed in IMO Resolution A.851(20) (Greek Flag Circular No.: 4413.6/05/2010 dated 09-03-2010) | Auditor/ CSQM/ MOC |
| The Administration is duly advised in writing in case of withdrawal of certificates, interim SMC extensions and any other notification - instructions under item 2 below | Recognised Organisation (RO) Piraeus |
| During DOC & SMC audits, the auditor also verifies that the SMM contains procedures on reporting of accidents & near miss incidents to HBMCI (the Hellenic Bureau for Marine Casualties' Investigation; www.hbmci.gov.gr), utilizing appropriate forms “Near miss report” and/or “Accident report for company”, e.g. as the two English specimen indicatively contained in the attached files. (Refer to “reporting near miss incidents” letter No 412411/10/2014 dated 18/02/14 file attached) | Auditor/CSQM |
|
The Greek Authorities had created the following check-lists to be used by the auditors as instructed in the front letter (to be kept in local file).
Evidences of their use shall be mentioned in the ASMS report item “Specific Flag requirements” by a remark.
Document Review
Company Audit
Shipboard Audit
Oil Tanker
Bulk Carrier
General Cargo ship
Passenger ship / Ro-Ro Passenger ship
High Speed Craft
Shipboard Functions Bridge
Engine Department
Letter of Greek Flag Administration concerning the subject:
See the attached file “LetterFromAdministrationOnISMAuditsChecklists”.
A free translation of the above letter:
See the attached file “translation”.
ISM Checklists:
See the attached files:
“Company Audit Check List Final”
“Document Review Check List”
“Shipboard Audit Oil Tanker ship Check List final”
“Shipboard Audit Bridge Functions Check List Final”
“Shipboard Audit Bulk Carrier Check List Final”
“Shipboard Audit Check List Final”
“Shipboard Audit Engine Functions Check List Final”
“Shipboard Audit General Cargo Ship Check List Final”
“Shipboard Audit Passenger Ships Ro Ro Passenger Ships Check List Final”
“Shipboard Audit High Speed Craft Check List final”
Instructions translated by Recognised Organisation (RO) Piraeus sent on 28/05/2009:
See the attached file “Greek ISM Instr”.
Specific Instructions
Publications to be carried on board
(Administration email dated 13/03/2019)
The requirements set forth by IMO MSC-MEPC.2/Circ.2 are to be regarded as mandatory.
In case of publications in electronic form, the SMS should contain provisions on the proper / controlled updating of these electronic publications, as well as on the existence of securely kept alternative copies thereof for use in eventual emergencies.
Additional audits for domestic passenger ships and tankers
(Refer to Greek FSA Circular No: 2341.5-1/57378/2020 dated 07/09/2020 in attached file “FSA Circular No 2341.5-1573782020.pdf”)
Additional inspection procedures were introduced for certain categories of Greek passenger ships engaged in regular domestic voyages (i.a.w. Law No 2932 /2001, as in force) and tankers engaged in the carriage of fuels domestically.
The ships' managers ; by considering the regular audits stipulated by Chapters 13 & 14 of the ISM Code; shall provide for the execution of additional shipboard audits in a way that ensures that the intervening time span between successive audits (interim, initial, intermediate, renewal, additional) does not exceed twelve months.
Medicine chests
(FSA Circular No: 2222.1-1/18399/2021)
Auditors shall verify that on board Greek ships the medicine chests are certificated in compliance with the requirements stated in Medicine chests.
Arrival and departure procedures, plans and instructions
The Administration mandates managing companies operating Greek passenger ships and ro-ro passenger ships engaged in regular routes to explicitly incorporate in their respective SMMs detailed instructions for berthing and departure; i.e. procedures, plans and instructions (including safe embarkations and disembarkations), as provided for in paragraph 7 of the ISM Code (Regulation (EC) 336/2006, Annex I Part A, as in force).
The compliance with this Administration’s requirement should be checked in the corresponding audit reports during the shipboard and shore-based audits:
The corresponding items applicable for ships are ISM073A (for interim audits) and ISM028B (for initial, periodical, and renewal audits)
The corresponding items applicable for the companies are ISM216 (for interim audits) and ISM028B (for initial, periodical, and renewal audits).
Analysis of non-conformities, system or engines’ malfunctions, accidents, observations and near-misses
(FSA Circular No: 2341.5-1/79630/2023)
In the context non-conformities, system or engines’ malfunctions, accidents, observations and near-misses, the managing entities shall ensure that the Deming cycle is systematically followed internally aiming at the applicable SMS’s continual improvement in a controlled and documented manner.
The establishment of e.g., new procedures, acknowledgement of new training requirements among the officers and crew members involved, as well as the sharing of lessons learnt among all ships of the managed fleet may become a part of a suitable corrective action plan.
The Administration has been informed about a variety of cases where the analyses conducted have led to apportioning the causal factors to either chance, or prevailing abnormal weather conditions. Under these circumstances it is highly advisable for a corresponding risk assessment to have been timely conducted so as for suitable response plans to be developed that might mitigate or palliate serious consequences in case of recurrence of similar phenomena, if not to eliminate repercussions of the latter altogether.
In case where the faulty engine sub-component, machinery, or specific spare part utilized onboard, it is important that these kinds of equipment to be accepted by the makers prior to being installed onboard, and that their periodic maintenance intervals, as foreseen by the maker’s manuals, to be complied with and to be incorporated in the corresponding proactive maintenance SMS forms / checklist.
Whenever causal factors of incidents are attributed to human element, it is to be checked whether those involved had acquired adequate training as per STCW and company’s SMS, and any potential fatigue emanating from not keeping MLC requirements on rest hours foreseen by national legislation were not met.
Non-conformities, system or engines’ malfunctions, accidents, observations and near-misses shall by default be subjected to investigations and analyses, whilst absence of similar records over a prolonged time constitutes an indication of non-conformance regarding the ISM Code’s explicit requirement.
Ballast Water Record Book
(Circular 2263.1-1414/24801/2025 in attached file “Circular_2263.1-1414_24801_2025_BWRB”)
Vessels subjected to the BWM Convention should have been furnished with the new BWMRB (available via the Greek Seafarers’ Pension Fund - NAT), by June 15, 2025, at the latest.
It is to be noted that as regards the proper record keeping, the BWRB should be kept onboard for a minimum of two years after the last entry made therein, and then, ashore, under the company’s control, for a minimum retention period of three years.
ISPS Code
Authorisations & Instructions
The issuance of ISPS certificates to Greek vessels can be undertaken by competent Administration's auditors, even after September 30th, 2018 (date wherefrom only authorized ROs can assume these tasks i.a.w. Law No 4504/2017 (Article 106 (1)).
| SSP Approval / Review | Ship Audit | ISSC Issuance |
|---|---|---|
| Yes | Yes | Yes |
Observation(s): - European Regulation (EC) No. 725/2004 of 31 March 2004 shall be applied from 1st July 2004. See instructions sent by Recognised Organisation (RO) Piraeus on 28/05/09 attached - Acceptance of SSPs in electronic format for ships flying the Greek flag is possible in the context of para 9.6 of Part A of the ISPS Code (email received from the competent FSA dated 20/06/2017). | ||
| Item | Specific Requirements | Observation(s) |
|---|---|---|
| Recognised Organisation (RO) Flag contact | See instructions sent by Recognised Organisation (RO) Piraeus attached | Primary contact: Recognised Organisation (RO) Piraeus |
| Audit request | Recognised Organisation (RO) Piraeus shall be immediately informed whenever one job is requested by the company directly to other Recognised Organisation (RO) units | |
| Interim ISSC extensions | Only granted by Flag Requests to be processed by Recognised Organisation (RO) Piraeus | |
| CSO/SSO Training | See attached instructions with details | |
| Audit Reports and ISSC submission to Administration | By MOC Piraeus (see attached instructions) | |
| Minimum period for filing records | 5 years for security records and drills / exercises 10 years for security incidents | |
| Ship Security Alert System (SSAS) | See instructions with details, in the attached file “Checklist for survey of Ship Security Alert System” | |
| Cyber security management | Managing companies shall include in their SSPs appropriate references to the applicable cyber security procedures which have been already established in the context of the ISM Code. | Recognised Organisation (RO) shall check conformity during audits/activities undertaken in the context of the ISPS Code. (see attached file “Cyber security procedures in the SSP”) |
| Security levels information | Refer to: https://www.hcg.gr/el/gia-ton-polith/nomo8esia/nomothesia-klados-elenchou-emporikon-ploemporikon-ploion-111/diey8ynsh-elegxoy-diaxeirishs-ths-asfaleias-ploiwn-kai-limenikwn-egkatastasewn-dedaple-1230/nomo8esia-egkyklioi-anakoinwseis-asfaleias-xrhsima-entypa-isps-1232/anakoinwseis-asfaleias-1240/ | |
| Document of reference | Appendix 1 to the Agreement Governing the Delegation of Statutory Inspections and Certification Service | |
Instructions sent by Recognised Organisation (RO) Piraeus on 28/05/2009: see the attached file “Greek ISPS Inst_Rev1”.
MLC, 2006
Scope of authorisation
The issuance of MLC certificates to Greek vessels can be undertaken by competent Administration's auditors, even after September 30th, 2018 (date wherefrom only authorized ROs can assume these tasks i.a.w. Law No 4504/2017 (Article 106 (1)).
| Yes | No | Observation | |
|---|---|---|---|
| Approval of DMLC II | X |
| Inspection | Certification | ||
|---|---|---|---|
| Yes | No | ||
| Full recognition (Recognised Organisation (RO) is RO) | X | X* | |
| * Specific Greek Certificates from System Certificate Editor are to be issued. | |||
Specific Flag Requirements
Extracts from “Implementation of the requirements of the Maritime Labour Convention, 2006 adopted by the International Labour Organisation”5. Accommodation, recreational facilitiesThe provisions of Chapter C of the National Regulation, with regard to construction and equipment, in implementation of Regulation 3.1, par. 2 of the Convention shall apply to all ships constructed on or after the 4th January 2014. A ship shall be deemed to have been constructed on the date when its keel is laid or when it is at a similar stage of construction. For existing ships for which these provisions of Chapter C do not have effect, the following shall be in effect:a. for ships on international voyages that are of gross tonnage over 500GT constructed after 18-7-1986, the provisions of l. 1637/1986 “Ratification of International Labour Convention no. 92 on the accommodation of ship crews (revised 1949) (Α' 107)” as in effect.b. for ships on international voyages that are of gross tonnage over 1000GT constructed after 19-5-1986, the provisions of l. 1637/1986 “Ratification of International Labour Convention no. 133 on the accommodation of ship crews (revised 1949) (Α' 65)” as in effect.c. for ships on international voyages that are of a gross tonnage over 100GT and less than 500GT, the provisions of P.D. 259/1981 “On the Regulation for the accommodation of the Captain and crew of Greek commercial ships” (Α' 72), as in effect.d. for ships on international voyages that are of gross tonnage over 500GT for issues that are not regulated explicitly or are not implemented in accordance with International Treaties 92 and 133, the provisions of P.D. 259/1981, as in effect.e. for the remaining ships on domestic routes, the provisions of P.D. 259/1981, as in effect and P.D. 221/2001 “Regulation of accommodation for passengers and crew of High Speed Craft” as in effect (A 171).The requirements of national legislation that concern construction issues about the accommodation on existing ships, in accordance with the above, are satisfied by the existence in effect of a Passenger Ship International Safety Certificate or an International Certificate of Cargo Ship Safety or an International Certificate of Safe Construction for Cargo Ships or a General Inspection Protocol in each instance.6. Ship’s CooksSeafarers who are employed on board ship as cooks shall have the appropriate proof, which is issued by the Ministry of Maritime Affairs and the Aegean’s Directorate for Seafarers’ Training (Chief Cook Degree; class A, B, or C Cook’s License).Certificates which are issued by countries that have ratified the Convention or the Certification of Ships’ Cooks Convention, 1946 (No. 69), shall be similarly acceptable. The seafarers in question cannot be younger than 18 years of age.E. SHIP CERTIFICATION – DECLARATION OF MARITIME LABOUR COMPLIANCE1. Ships that come under the field of implementation of article 31 of this National Regulation, i.e.:a. those of a gross tonnage of 500 or over, which carry out voyages from a country to a port outside that country;b. those of a gross tonnage for 500 or over, active from a port or between ports outside Greece;c. any ship following the request of the shipowner;
shall bear and maintain a Certificate of Maritime Labour that conforms to article 32 of the aforementioned Regulation, which certifies that labour and living conditions for seafarers on board ship, including measures for ongoing compliance included in the Declaration of Maritime Labour Compliance (DMLC) have been inspected and comply to national legislation or other measures that implement the Convention.2. The Declaration of Maritime Labour Compliance is attached to the Certificate and it shall have two Parts:a. Part I, which is shown in Appendix III and shall provide, inter alles, a reference to the relevant national legal provisions as well as concise information on the main content of the national requirements. In accordance with what is set out in the manual for Frequently Asked Questions (Revised Edition 2012) issued by the International Labour Organisation, if a recognised organisation has been suitably authorised by the competent authority of the Flag State to complete and issue the Certificate of Maritime Labour, then it can also be authorised to issue Part I of the DMLC, which is attached to the Certificate. In related matters, it should be noted that, in accordance with what is set out in Regulation 3 of jmd no. 4113.305/01/2013, the recognised organisations are “fully (F)” recognised as regards the issuing of the Declaration of Maritime Labour Compliance, i.e. including Part I and as such are able, besides the competent Authority of Regulation 1 which was similarly approved by the aforementioned joint ministerial decision, that being the Directorate for the Verification of Safety and Security Management of Ships and Port Facilities (DEDAPLE), shall sign Part I of the Declaration.
If an RO has been duly authorised by the flag State competent authority to clarify and issue the Maritime Labour Certificate, an RO could also be authorized to Issue the ΟΜΙ (Part I to be attached to the Certificate) (See C5.1.m. in Maritime Labour Convention, 2006 (MLC. 2006) Frequently Asked Questions (FAQ) which can be found online at:
b. Part II shall be drawn up by the shipowner and shall identify the measures adopted to ensure ongoing compliance with the national requirements between inspections and the measures proposed to ensure that there is continuous improvement. Specifically, they may set out the instances in which ongoing compliance with specific national requirements shall be certified, individuals who are responsible for the certification, files that must be maintained, as well as procedures that shall be followed when noncompliance is noted. References to other more comprehensive documentation, covering policies and procedures relating to other aspects of the maritime sector, such as documents required by the International Safety Management (ISM) Code or information required by the SOLAS Convention relating to the Ship’s Continuous Synopsis Record (CSR), shall be accepted for the purposes of Part II. An example of the kind of information that might be contained is set out in Appendix B5-I of the Convention. Part II is certified by DEDAPLE or by the suitably authorised classification society.
3. An authorised organisation may issue a Certificate if it judges that the results of the inspection it had carried out in past, e.g. within the framework of voluntary compliance by the shipowner, assure compliance to the relevant national requirements implementing the Convention. The relevant procedure must be set out in its quality assurance system.4. Additionally, it should be noted that in accordance with article 32 par. 12 of the National Regulation, Part II of the Declaration may be written solely in the English language in instances where the ship does not carry out domestic voyages.
5. Near Miss Incidents' reporting to the Company: The inspector shall verify that the ship's HSQE contains a relevant near miss incident reporting procedure which is to be systematically followed by the shipboard management in the context of MLC, 2006 Standard A 4.3.
Medicine chests
(FSA Circular No: 2222.1-1/18399/2021)
The medicine chests of vessels flying Greek flag shall, on and after 20 November 2021, comply with the amended Annexes II and IV to Council Directive 92/29/EEC; as provided for by Presidential Decree No 18/2021 (A’ 37). Auditors shall verify that on board Greek ships the medicine chests are certificated in compliance with those requirements; their content being in conformance with the amended Annexes II and IV of Presidential Decree No 376/1995 (A '206)
Amendments of 2014 to the MLC, 2006
Adherence to the requirements of the new items on “seafarers’ repatriation” & “shipowners’ liability” is to be verified on board Hellenic merchant ships subjected to MLC the latest by the next shipboard inspection undertaken for renewal of the MLC certificate after the international entry into force of the aforesaid MLC amendments.
Amendments of 2018 to the MLC, 2006
The amendments 2018 to the MLC, 2006 are formally incorporated into Greek National Law.
The DMLC Part I issuing process by the Administration is not being affected
DMLC Part II drawn up by the companies operating Greek ships shall include the provisions on:
continuation of economic remunerations to seafarers if those are held captive, and
the prolongation of validity of SEAs during their captivity period.
European Drinking Water Directive (EU) 2020/2184
The provisions of paragraph 2 of article 3 of the Directive (EU) 2020/2184 are applicable: vessels that desalinate water, carry passengers and act as water suppliers shall only be subject to Articles 1 to 6 and Articles 9, 10, 13 and 14 of this Directive and its relevant Annexes.
Amendments of 2022 to the MLC, 2006
(Refer to FSA Circular No. 2242.7-1.3/84536/2024)
Managing companies shall take into account the presidential decree's provisions (Presidential Decree No 66/2024, dated Nov. 21, 2024) by adapting their corresponding SMSs' requirements and by amending the corresponding DMLC Part(s) II, to the extent and degree necessary (Paragraph 4 of the Circular).
During the first MLC inspection executed for the issuance, or intermediate endorsement, or renewal of the MLC - after the international entry into force date of the Amendments (23/12/2024) -, the compliance with the 2022 Amendments shall be verified by the competent MLC Inspectors and those of the delegated MLC ROs (Paragraphs 5 and 6 of the Circular).
It should be noted though that the re-issuance of DMLC Part I by the Administration is not mandatory, at least during the present phase (Paragraph 7 of the Circular).
Appendix — Agreement governing the Delegation of Certification Services
Agreement
See the attached file “Agreement_Greece_RO SA_10042030”.
See the attached file “Letter_2311_1_14_40769_2023_Clarification_Paragraph_3.16”
Appendix 1 to the Agreement
Applicable instruments and degree of authorization
See the attached file “Appendix 1_Greece_RO SA”.
Appendix 2 to the Agreement
Reporting to the Administration
See the attached file “Appendix 2_Greece_RO SA”.
Appendix — Specific Certificates: National and bilingual International certificates.
List of National certificates
- Hellenic Load Line Certificate
- Hellenic Passenger Certificate - EUROSOLAS + Record Form P
- Certificate of Fitness of Cargo Gear and Lifts of Passenger Ships
- Commercial Yacht Inspection Certificate
- Protocol of General Inspection for Commercial/Pleasure Yacht
- Attestation of Successful Completion of Additional Control Procedures
- Hellenic Protocol Cargo Ships Tankers Certificate
- Hellenic Dynamically Support Craft (DSC Code)
- Hellenic Oil Pollution Prevention Certificate + Form A + Form B
- Hellenic Sewage Pollution Certificate
- Bollard pull test certificate
International Certificates
International Certificates must be bilingual Greek/English.