(1) The minimum summer freeboards shall be computed
in accordance with Regulations 27 (5), 27
(6), 27 (11), 28, 29, 30, 31, 32, 37 and 38,
except that Regulation 37 is modified
by substituting the following percentages for those given in Regulation 37:
|
Total Effective Length of Superstructures
|
|
|
0
|
0.1
L
|
0.2
L
|
0.3
L
|
0.4
L
|
0.5
L
|
0.6
L
|
0.7
L
|
0.8
L
|
0.9
L
|
1.0
L
|
Percentage
of deduction for all types of superstructure
|
20
|
31
|
42
|
53
|
64
|
70
|
76
|
82
|
88
|
94
|
100
|
|
|
|
|
|
|
|
|
|
|
|
|
Percentages at intermediate lengths of superstructures
shall be obtained by linear interpolation.
(2) The Winter Timber Freeboard shall be obtained
by adding to the Summer Timber Freeboard one thirty-sixth of the moulded
summer timber draught.
(3) The Winter North Atlantic Timber Freeboard
shall be the same as the Winter North Atlantic Freeboard prescribed
in Regulation 40 (6).
(4) The Tropical Timber Freeboard shall be obtained
by deducting from the Summer Timber Freeboard one forty-eighth of
the moulded summer timber draught.
(5) The Fresh Water Timber Freeboard shall be
computed in accordance with Regulation 40
(7) based on the summer timber load waterline.