9.1 Structural fire protection
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - 1979 MODU Code – Code for the Construction and Equipment of Mobile Offshore Drilling Units – Resolution A.414(XI) - Chapter 9 – Fire Safety - 9.1 Structural fire protection

9.1 Structural fire protection

  9.1.1 These requirements have been formulated principally for units having their hull superstructure, structural bulkheads, decks and deckhouses constructed of steel.

  9.1.2 Units constructed of other materials may be accepted, provided that, in the opinion of the Administration, they provide an equivalent standard of safety.

  9.1.4 Windows and sidescuttles, with the exception of navigating bridge windows, should be of the non-opening type. Navigating bridge windows may be of the opening type provided the design of such windows would permit rapid closure. The Administration may permit windows and sidescuttles outside hazardous areas to be of the opening type.

  9.1.5 External doors in superstructures and deckhouses should be constructed to "A-O" Class divisions and be self-closing, where practicable.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.