The references to the subsections in this Code, references to the relevant IMO
instruments or standard and subjects are in the following tables. Column 1 contains the
references to the subsection numbers in this Code. Column 2 contains the references to the
relevant IMO instruments or reference standard. Column 3 identifies the relevant
subjects.
Reference to
subsections in this Code (1)
|
Reference to the
relevant IMO instruments or standard (2)
|
Subject (3)
|
13.2.1 Dangerous goods and classification
13.2.2 Stability
13.2.3 Fire-extinguishing arrangements
General Group B
|
SOLAS II-2/10.7
|
Fire-extinguishing
arrangements in cargo spaces
|
General Group B
|
FSS
Code, chapter 5
|
Fixed
Gas Fire-Extinguishing Systems
|
General
|
FSS Code, chapter 9
|
Fixed fire detection
and fire alarm systems
|
General
|
FSS
Code, chapter 10
|
Sample
extraction smoke detection systems
|
Group B
|
SOLAS
II-2/19
|
Special requirements for ships carrying dangerous goods
|
Group A, B and C
|
MSC.1/Circ.1395/Rev.4
|
List of
solid bulk cargoes for which a fixed gas fire-extinguishing system may be
exempted or for which a fixed gas fire-extinguishing system is
ineffective
|
13.2.4 Ventilation
General Group B
|
International
Convention on Load Lines 1966, Annex I, regulation
19
|
Ventilation
openings
|
General Group B
|
SOLAS
II-2/9.7
|
Ventilation systems
|
General Group B
|
SOLAS II-2/19.3.4
|
Ventilation for ships carrying dangerous goods
|
General Group B
|
MSC.1/Circ.1434
|
Unified
Interpretation of SOLAS II-2/19.3.4
|
General Group B
|
MSC.1/Circ.1120
|
Unified
Interpretation of SOLAS including II-2/19.3.2, 19.3.4 and 19.3.4.2
|
General Group B
|
IEC
60092-506
|
Electrical standards
for equipment safe for use in an explosive atmosphere
|
13.2.5 Personnel protection
13.2.6 Gas detection
General
|
SOLAS
VI/3
|
Oxygen analysis and
gas detection equipment
|
General
|
Recommendations on the safe use of pesticides in ships applicable to the
fumigation of cargo holds (MSC.1/Circ.1264), as amended by MSC.1/Circ.1396
|
Gas
detection equipment for fumigation
|
General
|
IEC
60092-506
|
Electrical standards
for equipment safe for use in an explosive atmosphere
|
13.2.7 Minimum information/documentation
13.2.8 Insulation of machinery space boundaries
13.2.9 Fumigation
3.6
|
Recommendations on
the safe use of pesticides in ships applicable to the fumigation of cargo
holds (MSC.1/Circ.1264), as amended by MSC.1/Circ.1396),
section 3
|
Fumigation,
application of fumigation, fumigants, safety precautions
|
3.6
|
SOLAS
VI/4
|
Use of pesticides
in ships
|
13.2.10 Segregation
9.3
|
SOLAS
VII/7-3
|
Stowage and
segregation requirement
|
Group B
|
IEC
60092-352
|
Standards for
electrical cable penetrations in boundaries
|
13.2.11 Transport of solid wastes in bulk
10.4
|
Basel Convention on
the Control of Transboundary Movements of Hazardous Wastes and their
Disposal (1989)
|
Permitted
transboundary movement of wastes
|
10.6
|
IMDG Code,
subsection 2.0.5.4
|
Classification of
wastes
|
13.2.12 Entering enclosed spaces
3.2.4
|
resolution
A.1050(27), 30 November 2011
|
Revised
recommendations for entering enclosed spaces aboard ships
|
13.2.13 Avoidance of excessive stresses
2.1.2
|
SOLAS
XII/5 and 6
|
Structural strength of bulk carriers and structural and other requirements
for bulk carriers
|
2.1.2
|
SOLAS
XII/11
|
Loading instrument
|
2.1.2
|
Resolution A.862(20), as amended
|
Code of Practice for the Safe Loading and Unloading of Bulk
Carriers (BLU Code)
|
2.1.2
|
MSC.1/Circ.1357
|
Additional considerations for the safe loading of bulk
carriers
|