6.2.1 Lighting
fittings are to be of a certified safe-type and be arranged on at
least two independent final branch circuits. Switches and protective
devices are to interrupt all lines or phases and are to be located
outside the space.
6.2.2 Where
electric motors driving ventilation fans are located within the spaces,
within ventilation ducts, or within three metres of ventilation openings,
they are to be of a certified safe-type.
6.2.3 Monitoring
control and alarm systems which are required to operate under conditions
of ammonia leakage are to be of a certified safe-type.
6.2.4 Electrical
equipment which is not of a certified safe-type is to de-energise
automatically if the ammonia concentration within the space exceeds
1,0 per cent by volume.