| Item
|
Alarm
|
Note
|
| Thruster, azimuth or tunnel
|
-
|
Indicators, see
Pt 12, Ch 3, 6.2 Monitoring and alarms 6.2.2
|
| Azimuthing motor
|
Power failure, single phase
|
Also running indication on bridge and
at machinery control station
|
| Propeller pitch motor
|
Power failure
|
Also running indication on bridge and
at machinery control station
|
| Propulsion motor
|
Overload, power failure
|
Also running indication on bridge and
at machinery control station
|
| Control system
|
Failure
|
|
| Hydraulic oil supply tank
level
|
Low
|
|
| Hydraulic oil system pressure
|
Low
|
|
| Hydraulic oil system
temperature
|
High
|
Where oil cooler is fitted
|
| Hydraulic oil filters differential
pressure
|
High
|
Where oil filters are fitted
|
| Lubricating oil supply
pressure
|
Low
|
If separate forced
lubrication
|