5.2.2 A system
of alarm displays and controls is to be provided which readily ensures
identification of faults in the machinery and satisfactory supervision
of related equipment. The alarm and control systems are to satisfy
the requirements of Pt 16, Ch 1, 2.3 Alarm systems and Pt 16, Ch 1, 2.5 Control systems, as applicable.
5.2.3 Indication
of all essential parameters necessary for the safe and effective operation
of the machinery is to be provided, e.g. temperatures, pressures,
tank levels, speeds, powers, etc.
5.2.4 Indication
of the operational status of running and standby machinery is to be
provided.
5.2.5 At the
centralised control station, means of communication with the bridge
area, the accommodation for engineering personnel and, if necessary,
the machinery space are to be provided.
5.2.7 Arrangements
are to be provided in the centralised control station so that the
normal supply of electrical power may be restored in the event of
failure.