Approval and use of Statutory Service Suppliers

Revision of IACS UR Z17

Principle

Introduction

In making decision affecting statutory certification, the Surveyor may use the services of companies involved in measurements, tests or maintenance of safety systems and equipment. The basic standards for qualifying service suppliers are set forth in the Annex of this TNS.

The purpose of this TNS is to describe the process leading to the issuance of the Certificate of Approval for the following activities :

  1. inspections and maintenance of fire extinguishing equipment and systems

  2. servicing on inflatable liferafts, inflatable lifejackets, hydrostatic release units, marine evacuation systems.

  3. inspections and testing of radio communication equipment

  4. inspections and maintenance of self contained breathing apparatus

  5. annual performance testing of Voyage Data Recorders (VDR) and simplified Voyage Data Recorders (S-VDR)

  6. inspections of low location lighting systems using photo luminescent materials and evacuation guidance systems used as an alternative to low-location lighting systems

  7. sound pressure level measurements of public address and general alarm systems on board ships

  8. maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances, and release gear

  9. inspection, performance testing and maintenance of Automatic Identification Systems (AIS)

  10. measurements of noise level on board ships

  11. Watertight Cable Transit Seal Systems inspection on ships and Mobile Offshore Units. Refer to this procedure Annex 9.

  12. Commissioning Testing of Ballast Water Management System (BWMS) - APPLICABLE FROM 1 JANUARY 2022

Implementation

The NR 533 supersedes the Chapter 5 of NR 320 as from 15/09/2007. Issuance and Renewal of certificates shall be carried out in accordance with the requirements of this TNS and of NR 533.Some Service Providers are not specifically covered in this TNS or URZ17, such as Service providers for navigational equipment and systems. They can be Authorized as per procedure detailed in Approval of other service suppliers.

RECOGNITION PROCESS

As from 15th of July 2021, a new tool for approval of service suppliers and issuance of certificate is deployed on ASMS2.• Any new approval will have to be carried out through ASMS2.• Any in progress approval will have to be complete by using the existing process.The specificities of the new system are described in Recognition process

Approval process of a Company

  1. The approval process of a service supplier consists in:

    1. the review of the application file;

    2. an assessment, to ensure that the Company has the adequate resources and competence for the services it provides;

    3. the issuance of the certificate which is conditional on a practical demonstration of the performance of the specific service as well as satisfactory reporting being carried out.

      At initial audits, when the service supplier is already certified by other Classification Society subject to verification of compliance with QSCS in accordance with Section 5 of Annex 1 to the QSCS, in accordance with to the provision of URZ17, this may be verified through documentary review that a practical demonstration has already been carried out.

      At renewal audits, verification by documentary review of jobs undertaken since the previous audit and that have been accepted by a Classification Society subject to verification of compliance with QSCS in accordance with Section 5 of Annex 1 to the QSCS, is acceptable and is sufficient to satisfy this requirement.

  2. Unless otherwise specified, the Society may consider, at its own discretion, to waive from or to reduce the approval process when the Company has been already certified by :

    1. a Flag Administration; or

    2. an IACS Member; or

    3. an accreditated certifying body.

  3. The qualification principle given in the section 1 to 3 of the NR 533 can be used as a basis for the approval of service suppliers involved in activities other than those listed in the Appendix to the NR533.

Recognition by an other organization

Untitled

For such Statutory services on board ship, the Society may accept approvals done by:

  1. the flag Administration itself,

  2. duly authorized organizations acting on behalf of the flag Administration, or

  3. other organizations those are acceptable to the flag Administration (e.g. other governments, etc.).

Untitled

Use of the approved service suppliers is not mandatory for the following services, unless instructed otherwise by the flag Administration with respect to statutory certification

  • Firms engaged in inspections of low location lighting systems using photo luminescent materials and evacuation guidance systems used as an alternative to low-location lighting systems

  • Firms engaged in sound pressure level measurements of public address and general alarm systems on board ships

  • Firms engaged in measurements of noise level onboard ships

Small Companies

Special consideration shall be given to Companies with 3 or less employees. The lead auditor, with the agreement of the head of the local Recognised Organisation (RO) Office is responsible to ensure that the requirements are fulfilled as far as practicable and to the extent possible.

Issuance of the certificate

Untitled

Upon satisfactory completion of both the audit of the supplier and the demonstration test, if required, the Society issues a Certificate of Approval stating that the supplier's service operation system has been found to be satisfactory and that the results of services performed in accordance with that system may be accepted and used by the Society's Surveyors in making decisions affecting Statutory certification, as relevant.

The document shall clearly state the type and scope of services and any limitation or restrictions imposed including type of equipment and/or names of Manufacturers of equipment where this is a limiting restraint.

Untitled

Where one Service Supplier is involved in several activities covered by this TNS, he shall be issued with one certificate per activity.Combined certificate is not allowed.

Untitled

Certificates of approval are issued through ASMS2 Certificates (Web). ASMS2 Service Supplier and ASMS Company databases are linked together. Before issuing an Approval Certificate, it shall be ensured that the service supplier has been created in the Company database.

Nominated agents/subsidiaries

  1. If a manufacturer of equipment (and/or its service supplier) applies to the Society for inclusion of its nominated agents and/or subsidiaries (excluding any subcontractor) in the approval, then it must have implemented a quality system certified in accordance with the most current version of ISO 9000 series. The quality system must contain effective controls of the manufacturer’s (and/or service supplier’s) agents and/or subsidiaries.

    The nominated agents/subsidiaries must also have in place an equally effective quality system complying with the most current version of ISO 9000 series. Such approvals shall be based upon an evaluation of the quality system implemented by the parent company against the most current version of ISO 9000 series.

    The Society may require follow-up audits on such agents or subsidiaries against the most current version of ISO 9000 series to confirm adherence to this quality system.

  2. A company which works as a service station for manufacturer(s) of equipment (and as a service supplier in this field), shall be assessed by the manufacturer(s) and nominated as their agent. The manufacturer shall ensure that appropriate instruction manuals, material etc. are available for the agent as well as of proper training of the agent’s technicians. Such suppliers shall be approved either on a case by case basis, or in accordance with sub paragraph a) above.

subcontractor

Service supplier shall give information of agreements and arrangements if any parts of the services provided are subcontracted. Particular emphasis shall be given to quality management by the service supplier in following-up such subcontracts. Subcontractors providing the services of the approved service supplier shall also meet the requirements of this TNS and shall be separately approved and certified

Information regarding alterations to the Certified Service Operating System

When an alteration occurs to the supplier’s Certified Service Operating System, the Society shall be immediately informed thereof.

Re-audit may be required where deemed necessary by the Society.

Re-audit may be required where deemed necessary by the Society.Periodic audit, may be required where deemed necessary by the Administration or the Society, in order to ensure that work continues to be carried out in accordance with the Requirements for maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances and release gear as per resolution MSC.402(96) as amended, and the Administration or the Society may withdraw the authorization of service providers who are not in compliance.

Change of company's particulars

In case of change in company's status, name or particulars in the “Company” database, those changes will automatically be reflected in the “Service Suppliers” database.

Change of status

If the status of the company is moved to “inactive”, it will not be possible to issue any certificate.

The curent certificate shall be withdrawn from the service suplier and cancelled in the database.

Change of name

The existing certificate shall be cancelled and a new certificate issued, with the previous validity date.

Extension of services

In case of extension of services, the scope of the additional audit is to be as for an initial audit (of theextended service), as appropriate. The report is to clearly indicate the scope applied.

Cancellation of approval

  1. The Society reserves the right to cancel the approval and to inform the IACS Members accordingly.

  2. Approval may be cancelled in the following cases :

    1. where the service was improperly carried out or the results were improperly reported,

    2. where a Surveyor finds deficiencies in the supplier's approved service operating system and appropriate corrective action has not been taken,

    3. Where alterations have been made to the Company’s Quality System relevant to the service supplier certificates, without written notification to the Society.

    4. where the intermediate audit, if requested in the relevant Annex, has not been carried out,

    5. where wilful acts or omissions are ascertained.

    6. Where any deliberate misrepresentation has been made by the Service Supplier.

  3. A supplier who has had his certification cancelled may apply for re-approval provided it has corrected the non-conformities which resulted in cancellation, and the Society is able to confirm it has effectively implemented the corrective action.

  4. Expiration or cancellation of the Supplier’s parent company approval automatically invalidates approval of all agents and subsidiaries if these are certified according to Nominated agents/subsidiaries

Renewal

Renewal of the Certificate is to be made at intervals not exceeding 3 years by verification through audits that approved conditions are maintained or, where applicable, on expiry of the supplier’s approval received from an equipment Manufacturer, whichever comes first. In the latter case, the Society is to be informed in due course by the Service Supplier.

Existing Certificates

Approvals for the categories of service suppliers granted before the date of implementation of a version of this TNS remain valid as stated in the respective certificates for a period up to but not exceeding 3 years. Renewals of such certificates must be carried out in accordance with the latest version of the TNS.

Recognition process

Recognition process

Untitled

1 - Recognition - Application fileInstructionsForm
1Service supplierContact the Local Recognised Organisation (RO) Office for approval  
2Local Recognised Organisation (RO) OfficeSend NR 533 and the application formNR 533 Section 2See the attached file “Application form”
3Service supplierSend the application file to the Local Recognised Organisation (RO) office (1)  
4Local Recognised Organisation (RO) OfficeAcknowledge receipt of the application file, reviews the application file and issues the quotationthis procedure (Principle) NR 533 Section 2.2See the attached file “Documentation to be submitted”
5NS Operations ManagerTransmits the quotation, and where necessary, notifies the missing information to the Service Supplier Application form
6Service supplierAccept the quotation Application form
7Local Recognised Organisation (RO) OfficePrepare and send the contract together with the Recognised Organisation (RO) M&O General Condition Refer to procedure LEG_0001 for Recognised Organisation (RO) M&O General Condition
8Service supplierSign the contract  

Untitled

Performance of the initial/renewal assessment – ASMS2 Service Suppliers job / Service Suppliers Certificates

  1. Initial assessment:

    When using ASMS2, the documentation file stated in the corresponding Annex of NR533 is attached to the audit report.Upon a satisfactory audit and practical demonstration, the surveyor issues the interim certificate.The report is sent with the documentation to the SSQM/DSSQM for review and validation.Once validated by the SSQM/DSSQM, it is sent to the MOC for acknowledgement and validation. Upon acknowledgement, the MOC surveyor issues the full term certificate. (ref. Figure)Further to satisfactory review, the certificate is valid for a period of maximum of 3 years from the date of the audit.

  2. Renewal assessment:

    For renewal assessments of existing service suppliers, upon satisfactory completion of the renewal audit, the surveyor issues the full term certificate. (ref. Figure)As for initial assessments, the validity of the certificate is to be based on the date of the audit.

graph1

• Company Tool & Neptune (Service Suppliers Jobs):Each new Service Supplier for which a Job is planned will need to be registered as new “Service Supplier” type in Company Tool.• ASMS2 (Service Suppliers Jobs) (2)(3):Service Suppliers Jobs Process are available in ASMS2 (Web + Local) for Surveyors(4)

SSQM & DSSQM are able to validate Service Suppliers Jobs completed by Surveyors (4) directly from their Dashboard in ASMS2 Web.• ASMS2 Certificate (Service Suppliers Certificates):Service Suppliers Certificate Issuance process is available in ASMS2 Certificates-Surveyors(4) can create documents, issue interim certificates for initial verification, issue full term certificates for renewal verification and submit reports to SSQM/DSSQM.- SSQM/DSSQM can create and issue documents in ASMS2 Certificates (Create, Preview, Issue) or issue /deny submitted documents

- MOC surveyors will be able to acknowledge jobs, after SSQM/DSSQM validation step, also from their dashboard in ASMS2 and issue interim/full term certificates.

Certificates can be issued in either paper or electronic format.

(1) Where several Service Suppliers are owned by a given company, each station is to be assessed and approved except if the company and its nominated agents and/or subsidiaries have implemented an ISO 9000 series quality system with effective controls of the agents and subsidiaries to be included in the Certificate of Approval.(2) This includes, where necessary, a practical demonstration of the specific service performance as well as satisfactory reporting being carried out(3) Additional audits may be requested by the Lead Surveyor(4) Staff authorized to perform the assessment: Surveyor certified as per DO-FM procedures (see paragraph 3.1.13 of the ships-in-service personnel qualification and certification scheme).

Scope of assesSment

Untitled

See the attached file “Scope of Assessment”.

Requirement and procedures

Requirement and procedures

Statutory ServiceNR533Appendix (1)Approval by Manufacturer compulsory(3)ASMS2 Service Suppliers audit codes (4)ASMS2 Service Suppliers Certificate
Fire extinguishing and fire detection equipment and systemsPar.4Yes for fire detection onlyInitial : FFEIRenewal : FFERAdditional : FFEAYes
Inflatable liferafts, inflatable lifejackets, HRUs, marine evacuation systemsPar.5YesInitial: INFIRenewal: INFRAdditional: INFAYes
Radio communication equipmentPar.6NoInitial: RADIRenewal: RADRAdditional: RADAYes
Automatic Identification Systems (AIS)Par.6NoInitial: AISIRenewal: AISRAdditional: AISAYes
VDR & S-VDRPar.10YesInitial: VDRIRenewal: VDRRAdditional: VDRAYes
Self contained breathing apparatusPar.7NoInitial: SCBIRenewal: SCBRAdditional: SCBAYes
Low location lighting systems using photo luminescent materials and evacuation guidance systems used as an alternative to low location lighting systemsPar.8NoInitial: ILLIRenewal: ILLRAdditional: ILLAYes
Sound pressure level measurements of public address and general alarm systemsPar.9NoInitial: SOLIRenewal: SOLRAdditional: SOLAYes
Lifeboats and rescue boats, launching appliances, and release gear - APPLICABLE FROM 1 JANUARY 2020Par.11No - (unless otherwise instructed by the Flag Administration)Initial: BOAIRenewal: BOARAdditional: BOAAYes
Noise level onboard shipsPar.12NoInitial: NOLIRenewal: NOLRAdditional: NOLAYes
Visual and/or Sampling Checks and preparation of Inventory of Hazardous MaterialsPar.15NoInitial: HAZIRenewal: HAZRAdditional: HAZAYes
Commissioning Testing of Ballast Water Management System(BWMS) APPLICABLE FROM 1 JANUARY 2022Par.19NoInitial: BWCIRenewal: BWCRAdditional: BWCAYes

1 - Service suppliers are to be “approved” by Recognised Organisation (RO) under the conditions prescribed by this procedure (not mandatory for service suppliers as per Untitled).2 - Staff authorized to perform the assessment : Surveyor certified as per DO-FM procedures. It is recommended to select Surveyors having been trained to perform ISO 9000 or ISM Code assessments. 3 - Approval by the equipment’s manufacturer: . The manufacturer's documentary evidence that the Service Supplier has been certified or licensed to service the particular makes and models of equipment for which approval is sought shall be provided.4 - checklists/reports are generated in ASMS2 by choosing the appropriate audit code corresponding to the type of supplier audited.

Requirements for Maintenance, thorough examination, operational testing, overhaul and repair of lifeboats, rescue boats and fast rescue boats, launching appliances and release gear – Resolution MSC.402(96) as amended

Untitled

IMO adopted amendments to SOLAS regulations III/3 and III/20 ( resolution MSC.404(96) entry into force 1 January 2020) to make mandatory the requirements for maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances and release gear, which are included resolution MSC.402(96).Requirements for maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances and release gear, which are included resolution MSC.402(96) supersede and mandate the requirements previously included in MSC.1/Circ.1206/Rev.1 and a MSC.1/Circ 1277.SOLAS regulations III/20 as amended by resolution MSC.404(96) address the questions "What is to be done?" and "When is it to be done?" and the MSC resolution MSC.402(96) address "How is it to be done?" and "Who does it?".

Untitled

IACS has revised unified requirements related to approval of service suppliers UR Z17, as per Rev.14 applicable from the 1st January 2020, to take into account the entry into force of IMO Res.MSC.402(96).IACS clarification/ common views / interpretations (refer to Requirements for Maintenance, thorough examination, operational testing, overhaul and repair of lifeboats, rescue boats and fast rescue boats, launching appliances and release gear – Resolution MSC.402(96).) apply, unless otherwise instructed b the flag Administration, refer to flag procedures.

Acceptance of personnel certified in accordance with ISO 23678:2022 (series)

Pending formal IMO decision to whether ISO 23678 could be referenced as an acceptable international standard in the resolution MSC.402(96) for the certification of servicing technicians and based on the fact that:- The ISO/PAS 23678 has now been officially published as an ISO standard, and - A number of Flag State Administrations accept this ISO 23678,Service supplier using ISO 23678 for the certification of their servicing personnel, may be approved on that basis, and the following sentence is to be added in the free field of part 5 "Other conditions" when drafting the certificate:“The acceptance of this service supplier on board a given ship, for which personnel are certified in accordance with ISO 23678:2022, is subject to the ship’s Flag State acceptance. “

Amendments - Resolution MSC.559(108)

IMO (MSC 108) adopted amendments to resolution MSC.402(96) to identify the ventilation system of totally enclosed lifeboats as a new component to be checked during annual thorough examination and operational test carried out by an approved service supplier.The amendments in Resolution MSC.559(108) enter into force on 1 January 2026.

Supplementary guidance for the approval of service suppliers engaged in Commissioning Testing of BWMS

NR 533 App.1, [19], provides requirements for Approval of service suppliers engaged in Commissioning Testing of BWMS. The recommendations of IACS REC 180 provide supplementary guidance to be considered in addition to the requirements of the mentioned NR.

China MSA local requirements for inspection and certification of Service Suppliers located in China

Refer to China MSA local requirements for inspection and certification of Service Suppliers located in China

Appendix — Approval of other service suppliers

(IACS Recommendation 89)

General

Firms engaged in the testing of navigational equipment and systems are not required to be approved as service suppliers under IACS Unified Requirement Z17, except for the VDR.The following is to be considered as a guidance when seeking or approving assistance for the surveyor during initial, annual,periodical or renewal surveys of navigational navigational equipment required by SOLAS Regulation V/19.The approval does not include the ability to service the equipment down to the “manufacturer level”.If a firm is not able to cover all groups of navigational equipment the groups of equipment for which the firm is approved should be listed on any certificate issued.

Process

Extent of engagement

Performing inspection and testing of navigational equipment and systems on board ships for compliance with SOLAS requirements.The service supplier engagements are divided into 5 groups of services as listed in the attached file “Extent of engagement”.

Preferably, the service supplier should seek approval for all of these groups in order to be approved as service supplier for navigational equipment and systems.

Approval of service suppliers according to a limited number of groups may be considered on a case by case basis.

Reference documents

The service supplier should have access to SOLAS Chapter V and all IMO Performance Standards relevant for each group of services as well as all IEC cross product standards (IEC 60945 and IEC 61162 series).

The IMO Performance Standards are listed in the table in the attached file “Extent of engagement”. Where different flag states have their own interpretations or requirements regarding particular equipment or systems, these need to be part of the instructions / procedures, and arrangements for updating the validity of such interpretations / requirements should be in place.

Personnel

The service supplier should provide evidence that the person carrying out the inspection has education from a technical school (a minimum two years’ programme of engineering or physical science) or from a nautical institution with relevant seagoing experience as a certified ship’s officer. Personnel should be trained in testing navigational equipment and systems, preferably by the manufacturer of the equipment. Personnel should also have passed training concerning initial, annual, periodical and renewal surveys and have proficiency in the English language commensurate with the work.Personnel testing colour calibration on ECDIS should, in addition, have a documented Ishihara colour vision deficiency test or equivalent and have colour vision not worse than would be required for seagoing service as an officer.

Procedures and instructions

The supplier should have documented procedures and instructions for carrying out the testing and examination of navigational equipment and systems. Such procedures and instructions should ensure tha the level of performance tests is in compliance with the relevant technical standards.The procedures should cover all types of equipment within the relevant group for which approval is sought. Dedicated checklists with appropriate pass criteria for each test / inspection should be available.

Equipment / publications

The service supplier should, as a minimum, have the applicable publications for the different groups of services.The supplier should have the major and auxiliary equipment (e.g. multi meter, earth fault finder, NMEA logger, AIS test set, sound generator, sound level meter, etc.) required for correctly performing the testing. A record of the test equipment used should be kept. The record should contain information on manufacturer and type of equipment, and a log of maintenance and calibrations.

Reporting

The service supplier should confirm by means of a documented report that the equipment has been tested satisfactorily.

Review and Verification

The surveyor should be on board to the extent necessary to control the process.The surveyor should confirm that no further testing is needed or specify additional testing.The surveyor should verify the report of the service supplier.

Appendix — China MSA local requirements for inspection and certification of Service Suppliers located in China

Untitled

See attached files “CHNP320_R2.7z”

Appendix — Requirements for Maintenance, thorough examination, operational testing, overhaul and repair of lifeboats, rescue boats and fast rescue boats, launching appliances and release gear – Resolution MSC.402(96).

Untitled

The below IACS clarifications / common views / interpretations apply, unless otherwise instructed by the flag Administration, refer to flag procedures

Authorized service supplier / manufacturer

Untitled

Paragraph 2.2.3 of the Annex to resolution MSC.402(96) defines that “Manufacturer means the original equipment manufacturer” (except when the original equipment manufacturer no longer exists or supports the equipment). Therefore, paragraph 7.1.1 of the Annex of resolution MSC.402(96) is to be read as “employment and documentation of personnel certified in accordance with a recognized national, international or industry standard as applicable, or a certification programme established either by an ORIGINAL EQUIPMENT MANUFACTURER or by any entity which has taken legal and legitimate responsibilities for equipment when the original equipment manufacturer no longer exists or supports the equipment.”

Untitled

Authorized Service supplier means an entity, other than the manufacturer as defined in paragraph 2.2.3 of annex of resolution MSC.402(96), authorized by the Administration in accordance with section 3 and section 7 of annex of resolution MSC.402(96).

Untitled

A manufacturer, as defined in paragraph 2.2.3 of annex of resolution MSC.402(96), is not required to be authorized in accordance with section 7 of annex of resolution MSC.402(96) when carrying out thorough examination, operational testing, overhaul and repair on equipment manufactured by themselves, or for which they have taken legal and legitimate responsibilities.

Untitled

A manufacturer, as defined in paragraph 2.2.3 of annex of resolution MSC.402(96), is required to be authorized in accordance with section 7 of annex of resolution MSC.402(96), when carrying out thorough examination, operational testing, overhaul and repair on equipment not manufactured by themselves, or for which they have not taken legal and legitimate responsibilities.

Make and type

Where reference is made to "make(s) and type(s)" of the equipment, the "make(s)" is the name of the manufacturer and the "type(s)" is the model, series of the equipment. For example, make and type could be "ABC lifeboat Co. Ltd. – freefall lifeboat series DEF".

Certification of personnel

1. The service supplier’s personnel are to be certificated as per the available national, international or industry standard as applicable, within its own training and qualification scheme developed for its own personnel (i.e. its own "certification" scheme). A service supplier may "use" the training and qualification scheme already established by an equipment manufacturer, provided that such a manufacturer grants to the service supplier the necessary "access" to its "certification" scheme.

2. The "certification" of the service supplier's personnel can to be done either by the service supplier itself or by the original equipment manufacturer, in accordance with section 8 of the Annex to resolution MSC 402(96), for each type and make of equipment.

3. Final certification of personnel by a service provider is meant for the personnel employed by the service provider only.

4. For "personnel certified in accordance with … a manufacturer's established certification programme", the programme shall only cover that manufacturer’s own equipment. However, where a manufacturer is acting as an approved service supplier for equipment not manufactured by themselves, its personnel shall be certified in accordance with a recognized national, international or industry standard, or a certification programme established by another manufacturer, as defined in paragraph 2.2.3 of annex of resolution MSC.402(96), to which it has been granted access, i.e. when Manufacturer A is carrying out servicing activities on equipment made by Manufacturer B, service personnel of Manufacturer A shall be certified in accordance with a recognized national, international or industry standard, or a certification programme established by Manufacturer B.

5. An original equipment manufacturer may only certify service supplier personnel for its own equipment, and a manufacturer’s program for certification of service supplier personnel may therefore only apply to their own products.

Recognized national, international or industry standard (such as ISO 23678:2022)

Refer to Acceptance of personnel certified in accordance with ISO 23678:2022 (series)

In conclusion

a) all service personnel (regardless of whether they work for the manufacturer or not) should be certified in accordance with a recognized national, international or industry standard as applicable, or the manufacturer’s certification programme; and b) as the certification programme has to take into account each make and type of equipment which is to be serviced, it cannot be a generic programme; but has to be a specific programme taking into account the requirements as established by the manufacturer of each equipment.

Untitled

The below IACS clarifications / common views / interpretations apply, unless otherwise instructed by the flag Administration, refer to flag procedures

IACS common view on how to interpret UR Z17 Para. 13.3:

IACS common view on how to interpret UR Z17 Para. 13.3:

  1. Can an ASP certify any personnel employed by one of its service agents worldwide but not directly employed by itself?

    IACS View: Yes, but such certification may be granted, subject to the condition that the technician (agent) is under contract with the certifying ASP and the agent is managed under the ASP’s Quality System (See para 5.5.3 of UR Z17). If this contract or quality system arrangement does not exist then the agent requires certification by the ASP company directly employing them. This would not prohibit an ASP from contracting another ASP for external training of their technicians (UR Z17/5.2.2): “In such cases, final qualification and certificate in addition to the training from external source is necessary from the employing ASP”. This is in line with IMO Resolution MSC.402(96)/8.1: “Personnel for the work specified in paragraphs 4.2 and 4.3 shall be certified by the manufacturer or authorized service provider”.

  2. Can any personnel be employed by multiple service suppliers at the same time?

    IACS View: MSC.402(96) and UR Z17 do not appear to prohibit personnel (technician) from employment by multiple ASP’s. However, the technician must have a contract with, and be certified by, each ASP. Certification of a technician from one ASP is not transferable to another ASP.

  3. What is the definition of the employment and what is the guideline for class surveyors in order to verify if the personnel is actually employed by service supplier or not?

    IACS View: There is no precise definition of employment in MSC.402(96) or UR Z17. However, taking into account that employment is regulated by the Labor Acts of the country where ASP is located / registered and that employees will be subject to the ASP’s quality system, as outlined in section 5.5 of UR Z17, a document or list of employed technicians as well as a list of nominated agents is verified by the Class surveyor during approval of the ASP (See para 5.1.1 of UR Z17).

Quality system as per resolution MSC.402(96) paragraph 7.1.5

QMS certification in accordance with ISO9000 for service supplier is not mandatory: According to the note in 7.1 of MSC. 402(96), a documented Quality system complying with the most current version of ISO 9000 series and including the items in 7.1.5, would be considered acceptable to fulfil the requirements of a documented and certified quality system. In case of a quality system in compliance with other standards, certification is required and the requirements of certification of the quality system may be fulfilled through approval of the service supplier by the RO unless otherwise instructed by the flag Administration.

Validity of existing Certificates

Rev.14 of IACS UR Z17, adopted in March 2019 and to be uniformly implemented by IACS Societies from the1st January 2020, includes the provisions of MSC.402(96), in its Annex 1, para.13 “Firms engaged in maintenance, thorough examination, operational testing, overhaul and repair of lifeboats and rescue boats, launching appliances and release gear”The previous revisions of UR Z17 (Rev.13 and previous revisions) already required mandatory compliance with MSC. 1/Circ.1277 and MSC. 1/Circ.1206/rev.1.Therefore, a service supplier currently holding such existing approval certificate (according to Rev.13 or previous revisions of UR Z17), can also be considered to be in compliance with the requirements of Resolution MSC.402(96).As a consequence, existing approval certificates issued in accordance with UR Z17 (Rev.13 and previous revisions) will remain valid after 01/01/2020, until their natural expiry date; Resolution MSC. 402(96) (through Rev.14 of UR Z17) will be applied to certificates issued on or after 1st January 2020.