Systems and types of equipment
|
Category
|
Description of equipment
|
1. Mechanical and
electrical equipment certification required
|
1A
|
Boil off heater
|
1A
|
Boil-off gas
compressor
|
1A
|
Turbo Expander
|
1A
|
Gas heat exchanger
|
1B
|
Burner
|
1B
|
Flare
|
1B
|
Cold vents
|
1A
|
Columns – tray or packed
type
|
|
1A
|
Tensioning system
|
|
1A
|
Structural bearings
|
|
1A
|
Cold vent boom
|
|
1B
|
Offloading hose
|
|
1A
|
Offloading hose end
valve
|
|
1A
|
Pig launcher/receiver
|
|
1A
|
Hawser strong point
|
|
1A
|
Heat exchanger – Shell &
tube, plate, annulus, printed circuit
|
|
1A
|
High pressure LNG pumps for
vaporiser
|
|
1A
|
High pressure natural gas sent
out system
|
|
1A
|
High pressure natural gas
vaporiser
|
|
II
|
Pneumatic line thrower
|
|
1B
|
Generators and motors over 100
kW
|
|
1B
|
Uninterruptible power
supplies, including battery chargers, with rating above 100
kVA
|
|
1A
|
Unloading arms (rigid type)
including couplings
|
|
1A
|
Unloading arms (scissor,
cantilever or A frame type) including couplings
|
|
1B
|
Explosion protected equipment
if not carrying a certificate from a recognised test
institution
|
|
1B
|
Filter strainers
|
|
1B
|
Air dryers – regenerative
type
|
|
II
|
All other electrical
equipment
|
|
1B
|
Main control panels
|
|
1A
|
Main storage tank discharge
pumps
|
|
II
|
Instrumentation
components
|
|
TA
|
Interbarrier space, insulation
space or tank void relief valves
|
|
1A
|
Gas turbines > 110 kW
rating
|
|
1A
|
Fire water pump skids
(Package)
|
|
1A
|
Gas compressor skid
(Package)
|
|
1A
|
Power generation skid
|
|
1A
|
Steam turbines
|
|
1A
|
Gears, shafts and couplings
> 110 kW
|
|
1A
|
Lifting appliances: see LR’s
Code for Lifting Appliances in a Marine Environment and
hoisting and handling
|
|
1A
|
Subsea facilities
|
|
1A
|
Hydraulic and pneumatic power
units
|
|
1A
|
Flexible risers
|
|
1A
|
Control umbilicals
|
|
TA
|
Cryogenic storage tank relief
valves
|
|
1A
|
Storage tanks over 1000
L
|
|
1A
|
Fired pressure vessels
|
|
1A
|
Subsea systems
|
|
1A
|
Substructure (cofferdam)
heating system
|
|
1A
|
Pressure vessels over 7 bar
design pressure or 200ºF design temperature
|
|
1B
|
Pumps – Rotary, positive
displacement, mono
|
|
1B
|
Quick release mooring
hooks
|
|
1B
|
Engines over 110 kW
|
|
1A
|
Fire pumps and fire pump
packages
|
|
1A
|
Switchboards
|
|
1A
|
Fixed fire-fighting
system
|
|
1A
|
Fixed fire and gas detection
system
|
|
1B
|
Utility pumps and air
compressors
|
|
1B
|
Valves - general
|
|
1B
|
Expansion joint
|
|
TA
|
Expansion joint in cryogenic
services
|
|
1B
|
Non standard valves
|
|
1B
|
ESD valve and actuator
|
|
TA
|
Expansion bellows
|
|
1A
|
Christmas tree block and
valves
|
|
1A
|
HPU and pneumatic
panels
|
|
1A
|
Dynamic positioning
system
|
|
1B
|
IGS system
|
|
TA
|
Cargo hoses
|
|
1A
|
Cargo loading
instrument
|
|
1B
|
Chemical injection skid –
pumps, vessels, measurement
|
|
1A
|
Piping for Class I
and Class II and boiler superheaters
|
|
1A
|
Mooring winches
and windlass
|
|
1A
|
Nitrogen supply
for storage tank containment system
|
|
TA
|
Spark arrestors
and vent heads, PV valves
|
|
1A
|
Spray/circulation/supply pumps
|
|
TA
|
Mooring
chain
|
|
TA
|
Hydraulic
actuator
|
|
TA
|
Anchor
|
|
TA
|
GRE piping
|
|
TA
|
Resins
|
|
1B
|
Secondary or
closed loop heating system for vaporiser
|
|
1A
|
Slug
catcher
|
|
TA
|
Chokes
|
|
1A
|
Winches and
windlasses
|
|
1A
|
Columns – tray or
packed type
|
|
TA
|
Communication
equipment
|
|
1A
|
Compressor –
Centrifugal, rotary, reciprocating or screw
|
|
TA
|
Fire and gas
control panel and indicator
|
|
TA
|
Master Mode
switch
|
|
TA
|
Fire hoses
|
|
TA
|
Anodes
|
1.
Marine system equipment to be built under survey as in Pt 5, Ch 1, 1 General
|
See Note
|
|
1A
|
Main propulsion
engines including their associated gearing, flexible couplings,
scavenge blowers and superchargers
|
1A
|
Machinery and
equipment for lowering deck structures of self-elevating
units
|
1A
|
Boilers supplying
steam for propulsion or for services essential for the safety or the
operation of the ship at sea, including superheaters, economisers,
desuperheaters, steam heated steam generators and steam receivers.
All other boilers having working pressures exceeding 3,4 bar (3,5
kgf/cm2), and having heating surfaces greater than
4,65 m2
|
|
1A
|
Auxiliary engines
which are the source of power for services essential for safety or
for the operation of the ship at sea
|
|
1A
|
Steering
machinery
|
|
1A
|
Athwartship
thrust units, their prime movers and control mechanisms
|
|
1B
|
All pumps
necessary for the operation of main propulsion and essential
machinery, e.g., boiler feed, cooling water circulating, condensate
extraction, fuel oil and lubricating oil pumps
|
|
1A
|
All heat
exchangers necessary for the operation of main propulsion and
essential machinery, e.g., air, water and lubricating oil coolers,
fuel oil and feed water heaters, de-aerators and condensers,
evaporators and distiller units
|
|
1A
|
Air compressors,
air receivers and other pressure vessels necessary for the operation
of main propulsion and essential machinery. Any other unfired
pressure vessels for which plans are required to be submitted as
detailed in Pt 3, Ch 11, 1.6 Lifting lugs or padeyes
|
|
1A
|
Valves and other
components intended for installation in pressure piping systems
having working pressure exceeding 7,0 bar
|
|
1A
|
Alarms and control
systems as detailed in Pt 6, Ch 1 Control Engineering Systems and Pt 7, Ch 1 Safety and Communication Systems
|
NOTES
|
Items marked TA are to be type approved.
|
1. Category for gears, shafts and couplings is to be
either 1A, 1B or II, depending on the category of the prime mover
associated with the unit.
|
2. Fire water pump (directly driven) can be considered
Category 1B. Fire water lift pump (not directly driven) of proven
design may be accepted by conformation of material, witness of
testing and review of fabrication documentation (1B). Fire water
pump packages are to be built under survey (1A).
|
3. For complex machinery and equipment packages,
categorisation and approval procedure to be agreed with on a case by
case basis, considering selection of materials, service and
complexity of design and fabrication method.
|
4. The approval procedure to be agreed with on a case by
case basis, depending on function and criticality. See relevant Rule
requirements, AS 4343, EC directives, Regulatory requirements,
specific purchaser requirement.
|
Additional Notes for classed pressure vessel
requirements. See also Pt 5, Ch 10,1.6.
|
Plans of pressure vessels are to be submitted in
triplicate for consideration where all the conditions in (a) or (b)
are satisfied:
|
(a) The vessel contains vapours or gases, e.g., air
receivers, hydrophore or similar vessels and gaseous vessels for fire-fighting, and
pV > 600
p > 1
V > 100
V = volume (litres) of gas or vapour space.
|
(b) The vessel contains liquefied gases, for
fire-fighting or flammable liquids, and
p > 7
V > 100
V = volume (litres).
|