10.1 Verify that the following documentation is
on board in a suitable format for permanent use:
-
.1 copy of the certificate of type approval for
the oil content meter;
-
.2 statement from the Administration, or from
a laboratory authorized by the Administration, to confirm that the
control section of the monitoring system has been type-tested in accordance
with the specifications for environmental testing contained in part
2 of the Annex;
-
.3 equipment manuals for major components of the
system;
-
.4 operations and technical manual approved by
the Administration, containing a technical description of the system,
operational procedures and back-up procedures in case of equipment
malfunction;
-
.5 installation specification; and
-
.6 installation check-out procedures.
10.2 Verify the completeness of the workshop certificate
for the oil content meter and the control section of the monitoring
system.
10.3 Verify that the system installation has been
carried out in accordance with the approved technical installation
specification referred to in paragraph
8.1.6.
10.4 Verify that:
-
.1 the oil content meter is identical to the one
for which the certificate of type approval has been issued;
-
.2 the installation of the oil content meter and
the control section of the monitoring system has been carried out
in accordance with the manufacturer's equipment specification; and
-
.3 the operational outlets are located in the
positions indicated on the drawing of the pumping and piping arrangements.
10.5 Verify that the workmanship of the installation
is satisfactory and, in particular, that the bulkhead penetrations
are to the relevant approved standard.
10.6 Verify that the monitoring system operates
correctly when tested in accordance with the approved procedures contained
in section 11 of these Guidelines
and Specifications.