Section
9 Superstructures and deck-houses
9.1 General
9.1.1 The term ‘erection’ is used in this Section to include both
superstructures and deckhouses.
9.1.2 Erections are to comply with
9.1.3 The scantlings of exposed bulkheads and decks of deckhouses are generally
to comply with the requirements of this Section, but increased scantlings may be
required where the structure is subjected to local loadings greater than those
defined in the Rules, see also
Pt 4, Ch 6, 9.1 General 9.1.6. Where there is no access from inside the
house to below the freeboard deck or into buoyant spaces included in stability
calculations, or where a bulkhead is in a particularly sheltered location, the
scantlings may be specially considered.
9.1.4 The scantlings of superstructures which form an extension of the side
shell or which form an integral part of the unit’s hull and contribute to the
overall strength of the unit will be specially considered. The upper hull structure
of column-stabilised units are to comply with Pt 4, Ch 6, 3 Watertight shell boundaries.
9.1.5 Any exposed part of an erection which may be subject to immersion in
damage stability conditions and which could result in down flooding is to have
scantlings not less than required for watertight bulkheads given in Pt 4, Ch 6, 7 Bulkheads.
9.2 Symbols
9.2.1 The following symbols and definitions are applicable to this Chapter,
unless otherwise stated:
L, B,
and as defined in Pt 4, Ch 1, 5.1 General.
b |
= |
breadth of deckhouse, at the positions under consideration, in
metres |
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e359.png) |
= |
span, in metres, of erection stiffeners and is to be taken as
the ‘tween deck or house height but in no case less than 2,0 m |
s |
= |
spacing of stiffeners, beams or longitudinals, in mm |
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e415.png) |
= |
standard spacing, in mm, of stiffeners, beams or longitudinals,
and is to be taken as:
- for 0,05L from the ends:
= 610 mm or that required by Pt 4, Ch 6, 9.2 Symbols 9.2.1.(b), whichever is the lesser
- elsewhere:
= 470 + 1,67 mm but forward of 0,2L from the forward
perpendicular is not to exceed 700 mm
|
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e589.png) |
= |
actual breadth of unit at the section under consideration,
measured at the weather deck, in metres |
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e630.png) |
= |
Rule length, L, but need not be taken greater than 250 m |
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e674.png) |
= |
Rule length, L, but need not be taken greater than 300 m |
D |
= |
moulded depth of unit, in metres, to the uppermost continuous
deck |
X |
= |
distance, in metres, between the after perpendicular and the
bulkhead under consideration. When determining the scantlings of deckhouse
sides, the deckhouse is to be subdivided into parts of approximately equal
length not exceeding 0,15L each, and X is to be measured to
the mid-length of each part |
β |
= |
1,0 + for ≤ 0,45 |
= |
1,0 + 1,5 for ≤ 0,45 |
is to be taken not less than 0,6 nor greater than 0,8. Where the
aft end of an erection is forward of amidships, the value of used for determining β for the aft end bulkhead is to be taken as
0,8
γ |
= |
vertical distance, in metres, from the maximum transit
waterline to the mid-point of span of the bulkhead stiffener, or the
mid-point of the plate panel, as appropriate |
δ |
= |
1,0 for exposed machinery casings and
elsewhere, but in no case to
be
taken less than 0,475
|
Table 6.9.1 Values of α
Position
|
α
|
Lowest tier – unprotected front
|
2,0 + 0,0083
|
Second tier – unprotected front
|
1,0 + 0,0083
|
Third tier
and above – unprotected front
|
0,5 + 0,0067
|
All tiers – protected
fronts
|
All tiers – sides
|
All tiers – aft end where aft of
amidships
|
0,7 + 0,001 – 0,8
|
All tiers – aft end where forward of
amidships
|
0,5 + 0,001 – 0,4
|
Table 6.9.2 Values of λ
Length L
in metres
|
λ
|
Expression for λ
|
20
|
0,89
|
L ≤ 150 m
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e1597.png)
|
30
|
1,76
|
40
|
2,57
|
50
|
3,34
|
60
|
4,07
|
70
|
4,76
|
80
|
5,41
|
90
|
6,03
|
110
|
7,16
|
130
|
8,18
|
150
|
9,10
|
150
|
9,10
|
150 m ≤ L ≤ 300 m
|
170
|
9,65
|
190
|
10,08
|
210
|
10,43
|
230
|
10,69
|
250
|
10,86
|
270
|
10,98
|
290
|
11,03
|
300
|
11,03
|
300
|
|
L ≥ 300 m
|
and above
|
11,03
|
λ = 11,03
|
9.3 Definition of tiers
9.3.1 The first, or the lowest tier, is an erection situated on the deck to
which D is measured. The second tier is the next tier above the lowest tier,
and so on.
9.3.2 For ship units and self-elevating units where the freeboard corresponding
to the required summer moulded draught for the unit can be obtained by considering
the unit to have a virtual moulded depth of at least one standard superstructure
height less than the Rule depth, D, measured to the uppermost continuous
deck, proposals to treat the first tier erection as a second tier, and so on, will
be specially considered. The standard height of superstructure is the height defined
in the International Convention on Load Lines, 1966.
9.4 Design pressure head
9.4.1 The design pressure head, h, to be used in the determination of
erection scantlings is to be taken as:
9.4.2 In no case is the design pressure head to be taken as less than the
following:
- Lowest tier of unprotected fronts:
minimum
h = 2,5 + 0,01 m
- All other locations:
minimum h = 1,25 + 0,005 m
9.5 Bulkhead plating and stiffeners
9.5.1 The plating thickness, t, of fronts, sides and aft ends of all
erections other than the sides of the superstructures where these are an extension
of the side shell, is not to be less than:
t |
= |
0,003s mm, |
but in no case is the thickness to be less than:
- for the lowest tier:
t = (5,0 + 0,01 ) mm,
but t +
tc not less than 5,0 mm.
- for the upper tiers:
t = (4,0 + 0,01 ) mm,
but t +
tc not less than 5,0 mm.
9.5.3 The modulus of stiffeners, Z, on fronts, sides and end bulkheads
of all erections, other than the sides of superstructures where these are an
extension of the side shell, is to be not less than:
Z |
= |
0,0035h s
k cm3
|
9.5.5 The section modulus of side frames of forecastles, bridges and poops is
to be as required by Pt 4, Ch 4, 4 Surface type units.
Table 6.9.3 Stiffener end
connections
Position
|
Attachment at top and
bottom
|
1. Front stiffeners of lower tiers
and of upper tiers when
L is 160 m or greater
|
See
Pt 4, Ch 8 Welding and Structural Details
See Note
|
2. Front stiffeners of upper tiers
when L is less than 160 m
|
May be unattached
|
3. Side stiffeners of lower tiers
where two or more tiers are fitted
|
Bracketed, unless stiffener modulus is
increased by 20 per cent and ends are welded to the deck all
round
|
4. Side stiffeners if only one tier is fitted,
and aft end stiffeners of after deckhouses
on deck to which D is measured
|
See
Pt 4, Ch 8 Welding and Structural Details
|
5. Side stiffeners of upper tiers
where L is 160 m or greater
|
See
Pt 4, Ch 8 Welding and Structural Details
|
6. Side stiffeners of upper tiers
when L is less than 160 m
|
May be unattached
|
7. Aft end stiffeners except as
covered by item 4
|
May be unattached
|
8. Exposed machinery and pump-room casings.
Front sitffeners on amid-ship casings and all
stiffeners
on aft end casings which are situated on the deck
to which D is measured
|
Bracketed
|
9. All other stiffeners on exposed machinery
and pump-room casings
|
6,5 cm2 of weld
|
NOTE
|
Front
stiffeners of lower tiers on self-elevating units are to be
bracketed.
|
9.6 Erections on self-elevating units
9.6.1 The scantlings of exposed ends and sides of erections are to comply with
9,5, but the additional requirements of this sub-Section are to be complied
with.
9.6.2 The plating thickness, t, of exposed lower tier fronts is to be
not less than:
t |
= |
0,0036s mm |
but in no case is the gross thickness t + tc to
be less than 7,0 mm.
9.6.3 The modulus of stiffeners, Z, on exposed lowest tier fronts is to
be not less than:
Z |
= |
0,0044h s
k cm3 |
9.6.4 Where the exposed side of an erection is close to the side shell of the
unit, the scantlings may be required to conform to the requirements for exposed
bulkheads of unprotected house fronts.
9.6.5 The scantlings of jackhouses will be specially considered, but are not
to be less than the scantlings that would be required for an erection at the same
location.
9.7 Erections on other unit types
9.7.2 When the erection is not subjected to wave forces in any condition then
the structure is to be suitable for the maximum design loadings but the minimum
scantlings of exposed sides and ends of all erections is to be not less than:
- for the lowest tier:
t = (5,0 + 0,01L) mm, but not t + tc less than 5,0
mm.
- for the upper tiers:
t = (4,0 + 0,01L) mm, but not t + tc less than 5,0
mm.
9.7.3 The modulus of stiffeners, Z, of exposed sides and ends of all
erections is to be not less than:
Z |
= |
0,0035h s
k cm3
|
where
9.7.4 The end connections of stiffeners not subjected to wave loadings are to
be as given in Table 6.9.4 Other unit types stiffener
end connections.
Table 6.9.4 Other unit types stiffener
end connections
Position
|
Attachment at top and
bottom
|
1. Side stiffeners of lower tiers
where two or more tiers are fitted
|
Bracketed unless stiffener
modulus is increased by
20 per cent and ends are
welded to the deck all around
|
2. Side stiffeners if only one
tier is fitted
|
See
Pt 4, Ch 8 Welding and Structural Details
|
3. All other stiffeners
|
May be unattached
|
9.8 Deck plating
9.8.2 For erections not subjected to wave forces in any condition, the
thickness of erection deck plating for all tiers need not exceed the requirements
given in Table 6.9.5 Thickness of deck
plating for third tier erections,
using:
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e3348.png) |
= |
470 + 1,67![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e3379.png) |
Table 6.9.5 Thickness of deck
plating
Position
|
Thickness of deck plating, in mm
|
L ≤ 100 m
|
L > 100 m
|
Top of first
tier erection
|
(5,5 +
0,02L)
|
but not less than 5,0 mm
|
7,5
|
Top of second
tier erection
|
(5,0 +
0,02L)
|
7,0
|
Top of third
tier and above
|
(4,5 +
0,02L)
|
6,5
|
NOTE
|
For units not subjected to wave loading, see
Pt 4, Ch 6, 9.8 Deck plating 9.8.2.
|
9.8.3 When decks are fitted with approved sheathing, the net thickness derived
from Table 6.9.5 Thickness of deck
plating may be reduced
by 10 per cent for a 50 mm sheathing thickness, or five per cent for 25 mm, with
intermediate values in proportion. The steel deck is to be coated with a suitable
material in order to prevent corrosive action, and the sheathing or composition is
to be effectively secured to the deck. Inside erections the net thickness may be
reduced by a further 10 per cent. In no case is the deck gross thickness to be less
than 5,0 mm.
9.8.4 The thickness, t, of forecastle deck plating is to be not less
than:
t |
= |
(6 + 0,017L) mm. |
9.9 Deck stiffening
9.9.1 The requirements for deck stiffeners in this sub- Section are applicable
to both beams and longitudinals.
9.9.2 Deck stiffeners on deckhouses are to have a section modulus, Z,
not less than:
Z |
= |
0,0048
s
k cm3, but in no case less than: |
where the load head, h6, is to be taken as not less than:
on first tier decks
|
0,9 m
|
on second tier
|
0,6 m
|
on third tier decks and
above
|
0,45 m
|
but where the deck can be subjected to weather loading, the load,
h6
, is to be increased in accordance with the requirements given in Pt 4, Ch 6, 2.3 Stowage rate and design heads 2.3.2.
9.10 Deck girders and transverse
9.11 Strengthening at ends and sides of
erections
9.11.1 Web frames or equivalent strengthening are to be arranged to support the
sides and ends of large erections.
9.11.2 These web frames should be spaced about 9 m apart and are to be arranged,
where practicable, in line with watertight bulkheads below. Webs are also to be
arranged in way of large openings, boats davits and other points of high
loading.
9.11.3 Arrangements are to be made to minimise the effect of discontinuities in
erections. All openings cut in the sides are to be substantially framed and have
well rounded corners. Continuous coamings or girders are to be fitted below and
above doors and similar openings. Erections are to be strengthened in way of
davits.
9.11.4 Adequate support under the ends of erections is to be provided in the
form of webs, pillars, diaphragms or bulkheads in conjunction with reinforced deck
beams.
9.11.5 At the corners of deckhouses and in way of supporting structures,
attention is to be given to the connection to the deck, and doublers or equivalent
arrangements should generally be fitted.
9.12 Unusual designs
9.12.1 Where superstructures or deckhouses are of unusual design, the strength
is to be not less than that required by this Section for a conventional design.
9.13 Aluminium erections
9.13.2 The thickness, t, of aluminium alloy members is to be not less
than:
t |
= |
2,5 + 0,022 mm but t + tc need not exceed 10
mm |
where
![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e4451.png) |
= |
depth of the section, in mm. |
9.13.3 The minimum moment of inertia, I, of aluminium alloy stiffening
members is to be not less than:
where l is the effective length of the member ![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e4519.png) or ![](svgobject/C61D-4D1B-8760-E3DF87E8827A.xml_d1234866e4548.png) , in metres, as defined in Pt 4, Ch 6, 9.2 Symbols and Z is the section modulus of the
stiffener and attached plating in accordance with Pt 4, Ch 6, 9.4 Design pressure head and Pt 4, Ch 6, 9.9 Deck stiffening, taking k as 1.
Table 6.9.6 Percentage increase of
scantlings
Item
|
Percentage
increase
|
Fronts, sides, aft ends, unsheathed
deck plating
|
20
|
Decks sheathed in accordance with
Pt 4, Ch 6, 9.8 Deck plating 9.8.3
|
10
|
Deck sheathed with wood, and on which
the plating is fixed to the wood sheathing at the centre of each
beam space
|
Nil
|
Stiffeners and beams
|
70
|
Scantlings of small isolated
houses
|
Nil
|
9.13.4 Where aluminium erections are arranged above a steel hull, details of the
arrangements in way of the bimetallic connections are to be submitted.
9.14 Fire protection
9.14.1 Fire protection of aluminium alloy erections is to be in accordance with
the fire safety Regulations of the appropriate National Administration, see
Pt 7, Ch 3 Fire Safety.
9.14.2 Where it is proposed to use aluminium alloy for items or equipment in
hazardous areas, incendive sparking may constitute a risk and full details are to be
submitted for consideration.
|