Dimension
|
Description
|
Requirement
|
Applicable to Notation
|
(see
Figure 1.5.1 Side view of working area between container stacks on hatch cover)
|
|
(mm)
|
ECL(1)
|
ECL(2)
|
ECL(3)
|
D
|
Height of fencing on lashing bridge
and working platforms
|
1000 minimum
|
√
|
√
|
√
|
L
|
Horizontal gap in fall
protection
|
300 maximum
|
√
|
√
|
√
|
GL
|
Width of working platform for
outboard lashing – fore/aft
|
750 minimum
|
√
|
√
|
√
|
GT
|
Width of working platform for
outboard lashing – transverse
|
750 minimum
|
√
|
√
|
√
|
A
|
Width of work area between container
stacks
|
750 minimum
|
|
√
|
√
|
B
|
Distance between lashings on deck or
on hatch covers
|
600 minimum
|
|
√
|
√
|
C1
|
Distance from lashing bridge fencing
to container stack
|
1100 maximum
|
|
√
|
√
|
C2
|
Distance from lashing plate to
container stack (lashing bridge)
|
220 minimum
|
|
√
|
√
|
C3
|
Distance from lashing plate to
container stack (elsewhere)
|
130 minimum
|
|
√
|
√
|
F
|
Width of lashing bridge between top
rails of fencing
|
750 minimum
|
|
√
|
√
|
F1
|
Width of lashing bridge between
storage racks, lashing cleats and any other obstruction
|
600 minimum
|
|
√
|
√
|
|
Width of work platform at end of
hatch cover or adjacent to superstructure
|
750 minimum
|
|
√
|
√
|
J
|
Distance from edge of hatch cover to
fencing
|
600 minimum
|
|
√
|
√
|
K
|
Width of lashing bridge between top
rails of fencing
|
750 minimum
|
|
√
|
√
|
K1
|
Width of lashing bridge between the
pillars of the lashing bridge
|
600 minimum
|
|
√
|
√
|
E
|
Vertical distance
from working level to lower end of lashing rod:
- Single height rod
- Double height rod
|
1600 maximum
1400 maximum
|
|
|
√
|
H
|
Gap in access or working
surface
|
60 maximum
|
|
|
√
|
NOTES
|
L -
See
Ch 1, 2.3 Fall protection 2.3.2. For example, see
Figure 1.5.3 Outboard working area.
|
GL -
Measured from end of container to inside of fencing.
|
GT -
Measured to inside of fencing.
|
B -
Measured between the centres of the lashing plates.
|
C1 -
Measured from inside of fencing. May be increased where necessary, but not
to exceed 1300 mm, provided there is clear indication in the CSM, see
Ch 1, 3.10 Lashing bridges 3.10.3.
|
C2, C3 -
Measured from centre of lashing plate to end of container.
|
F, K -
Measured to inside of fencing.
|
- Measured to inside of fencing.
|
J -
Measured to inside of fencing.
|
E -
Measured to lower end of lashing rod. This may be measured with the lashing
rod in the position when the upper end of the rod is being inserted or
withdrawn from the container corner casting, i.e. upper and lower ends of
the rod at approximately the same transverse distance from the centreline of
the vessel. May be waived provided there is clear indication in the CSM and
at the lashing position, see
Ch 1, 4.12 Lashing equipment 4.12.3.
|
H - To
prevent tripping and to prevent feet becoming trapped in the gap. May be
waived provided there is clear indication in the CSAP and at the position,
see
Ch 1, 4.2 Working areas 4.2.3 and Ch 1, 4.4 Transit areas 4.4.3.
|